본문 바로가기
KERD
논문KCI 등재

Accuracy of casts produced from conventional and digital workflows: A qualitative and quantitative analyses

0

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

PURPOSE. Comparing the accuracy of casts produced from digital workflow to that of casts produced from conventional techniques. MATERIALS AND METHODS. Whole arch alginate (ALG) and polyvinyl siloxane (PVS) impressions were taken with stock trays and custom trays, respectively. The ALG impressions were poured with type III dental stone, while the PVS impressions were poured with type IV dental stone. For the digital workflow, IOS impressions were taken and physical casts were produced by 3D printing. In addition, 3D printed casts were produced from images obtained from a laboratory scanner (LS). For each technique, a total of 10 casts were produced. The accuracies of the whole arch and separated teeth were virtually quantified. RESULTS. Whole arch cast accuracy was more superior for PVS followed by LS, ALG, and IOS. The PVS and ALG groups were inferior in the areas more susceptible to impression material distortion, such as fossae and undercut regions. The LS casts appeared to have generalized errors of minor magnitude influencing primarily the posterior teeth. The IOS casts were considerably more affected at the posterior region. On the contrary, the IOS and LS casts were more superior for single tooth accuracy followed by PVS and ALG. CONCLUSION. For whole arch accuracy, casts produced from IOS were inferior to those produced from PVS and ALG. The inferior outcome of IOS appears to be related to the span of scanning. For single tooth accuracy, IOS showed superior accuracy compared to conventional impressions.

Abstract

PURPOSE. Comparing the accuracy of casts produced from digital workflow to that of casts produced from conventional techniques. MATERIALS AND METHODS. Whole arch alginate (ALG) and polyvinyl siloxane (PVS) impressions were taken with stock trays and custom trays, respectively. The ALG impressions were poured with type III dental stone, while the PVS impressions were poured with type IV dental stone. For the digital workflow, IOS impressions were taken and physical casts were produced by 3D printing. In addition, 3D printed casts were produced from images obtained from a laboratory scanner (LS). For each technique, a total of 10 casts were produced. The accuracies of the whole arch and separated teeth were virtually quantified. RESULTS. Whole arch cast accuracy was more superior for PVS followed by LS, ALG, and IOS. The PVS and ALG groups were inferior in the areas more susceptible to impression material distortion, such as fossae and undercut regions. The LS casts appeared to have generalized errors of minor magnitude influencing primarily the posterior teeth. The IOS casts were considerably more affected at the posterior region. On the contrary, the IOS and LS casts were more superior for single tooth accuracy followed by PVS and ALG. CONCLUSION. For whole arch accuracy, casts produced from IOS were inferior to those produced from PVS and ALG. The inferior outcome of IOS appears to be related to the span of scanning. For single tooth accuracy, IOS showed superior accuracy compared to conventional impressions.

참고문헌 (28)

  1. Fokkinga WA, "Clinical fit of partial removable dental prostheses based on alginate or polyvinyl siloxane impressions", Int J Prosthodont, 30, pp.33~37 (2017)
  2. Gordon GE, "The effect of tray selection on the accuracy of elastomeric impression materials", J Prosthet Dent, 63, pp.12~15 (1990)
  3. Rueda LJ, "The effect of using custom or stock trays on the accuracy of gypsum casts", Int J Prosthodont, 9, pp.367~373 (1996)
  4. Ceyhan JA, "The effect of tray selection, viscosity of impression material, and sequence of pour on the accuracy of dies made from dual-arch impressions", J Prosthet Dent, 90, pp.143~149 (2003)
  5. de Araujo PA, "Effect of material bulk and undercuts on the accuracy of impression materials", J Prosthet Dent, 54, pp.791~794 (1985)
  6. Kuhr F, "A new method for assessing the accuracy of full arch impressions in patients", J Dent, 55, pp.68~74 (2016)
  7. Atieh MA, "Accuracy evaluation of intraoral optical impressions : A clinical study using a reference appliance", J Prosthet Dent, 118, pp.400~405 (2017)
  8. Ender A, "In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions", J Prosthet Dent, 115, pp.313~320 (2016)
  9. Flügge TV, "Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner", Am J Orthod Dentofacial Orthop, 144, pp.471~478 (2013)
  10. Ender A, "In-vitro evaluation of the accuracy of conventional and digital methods of obtaining full-arch dental impressions", Quintessence Int, 46, pp.9~17 (2015)
  11. Abduo J, "Trends in computer-aided manufacturing in prosthodontics : a review of the available streams", Int J Dent, 2014, pp.783948~ (2014)
  12. Al-Imam H, "Accuracy of stereolithography additive casts used in a digital workflow", J Prosthet Dent, 119, pp.580~585 (2018)
  13. Sim JY, "Comparing the accuracy(trueness and precision)of models of fixed dental prostheses fabricated by digital and conventional workflows", J Prosthodont Res, 63, pp.25~30 (2019)
  14. Jin SJ, "Accuracy of dental replica models using photopolymer materials in additive manufacturing : In vitro three-dimensional evaluation", J Prosthodont, 28, pp.e557~e62 (2019)
  15. Wesemann C, "Accuracy and efficiency of full-arch digitalization and 3D printing : A comparison between desktop model scanners, an intraoral scanner, a CBCT model scan, and stereolithographic 3D printing", Quintessence Int, 48, pp.41~50 (2017)
  16. Ishida Y, "Dimensional accuracy of dental casting patterns created by 3D printers", Dent Mater J, 35, pp.250~256 (2016)
  17. Abduo J, "Accuracy of intraoral scanners : A systematic review of influencing factors", Eur J Prosthodont Restor Dent, 26, pp.101~121 (2018)
  18. Eftekhar Ashtiani R, "Comparison of dimensional accuracy of conventionally and digitally manufactured intracoronal restorations", J Prosthet Dent, 119, pp.233~238 (2018)
  19. Anadioti E, "3D and 2D marginal fit of pressed and CAD", CAM lithium disilicate crowns made from digital and conventional impressions, 2014, pp.23, 610~617
  20. "ISO 5725-1. Accuracy (trueness and precision) of measurement methods and results - Part 1: General principles and definitions" (1994)[URL]
  21. Ender A, "Accuracy of complete-arch dental impressions : a new method of measuring trueness and precision", J Prosthet Dent, 109, pp.121~128 (2013)
  22. Jeong ID, "Accuracy of complete-arch model using an intraoral video scanner : An in vitro study", J Prosthet Dent, 115, pp.755~759 (2016)
  23. Atieh MA, "Accuracy evaluation of intraoral optical impressions : A clinical study using a reference appliance", J Prosthet Dent, 118, pp.400~405 (2017)
  24. Su TS, "Comparison of repeatability between intraoral digital scanner and extraoral digital scanner : An in-vitro study", J Prosthodont Res, 59, pp.236~242 (2015)
  25. Lee JJ, "Accuracy of single-abutment digital cast obtained using intraoral and cast scanners", J Prosthet Dent, 117, pp.253~259 (2017)
  26. Cho SH, "Comparison of accuracy and reproducibility of casts made by digital and conventional methods", J Prosthet Dent, 113, pp.310~315 (2015)
  27. Ng J, "A comparison of the marginal fit of crowns fabricated with digital and conventional methods", J Prosthet Dent, 112, pp.555~560 (2014)
  28. Rossini G, "Diagnostic accuracy and measurement sensitivity of digital models for orthodontic purposes : A systematic review", Am J Orthod Dentofacial Orthop, 149, pp.161~170 (2016)

관련 논문AI추천

Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition박찬진, 이예규, 조리라, 허윤혁대한치과보철학회 · The Journal of Advanced of Prosthodontics2015 · 제7권 제6호Comparison of the accuracy of digitally fabricated polyurethane model and conventional gypsum model김소연, 윤미정, 이소현, 전영찬, 정창모, 조승근, 허중보대한치과보철학회 · The Journal of Advanced of Prosthodontics2014 · 제6권 제1호Accuracy of intraoral scans of edentulous jaws with different generations of intraoral scanners compared to laboratory scansChristine Keul, Jan-Frederik Güth, Oliver Schubert, Panagiotis Kontis대한치과보철학회 · The Journal of Advanced of Prosthodontics2021 · 제13권 제5호Accuracy and reproducibility of 3D digital tooth preparations made by gypsum materials of various colorsChao Wang, Fa-Bing Tan, Hong-Wei Dai, Jin-Lin Song, Yu-Bo Fan대한치과보철학회 · The Journal of Advanced of Prosthodontics2018 · 제10권 제1호Comparison of accuracy between digital and conventional implant impressions: two and three dimensional evaluationsChuang Bi, Fangfang Tian, Jiaming Zhao, Xingyu Wang, Zhe Qu대한치과보철학회 · The Journal of Advanced of Prosthodontics2022 · 제14권 제4호Comparison of 3D accuracy of three different digital intraoral scanners in full-arch implant impressionsFunda Bayindir, Ismail Hakki Korkmaz, Ozcan Akkal대한치과보철학회 · The Journal of Advanced of Prosthodontics2023 · 제15권 제4호