Wear resistance of indirect composite resins used for provisional restorations supported by implants
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
PURPOSE. The aim of this study was to investigate simulated localized and generalized wear of indirect composite resins used for implant supported provisional restorations. MATERIALS AND METHODS. The study investigated ten indirect composite resins. Two kinds of wear were simulated by 400,000 cycles in a Leinfelder-Suzuki (Alabama) machine. Localized wear was simulated with a stainless-steel ball bearing antagonist and generalized with a flat-ended stainless-steel cylinder antagonist. The tests were carried out in water slurry of polymethyl methacrylate beads. Wear was measured using a Proscan 2100 noncontact profilometer in conjunction with Proscan and AnSur 3D software. RESULTS. Both localized and generalized wear were significantly different (P<.05) among the indirect composite resins. SR Nexco and Gradia Plus showed significantly less wear than the other indirect composite resins. The rank order of wear was same in both types of wear simulation. CONCLUSION. Indirect composite resins are recommended when a provisional implantsupported restoration is required to function in place over a long period. Although only some indirect composite resins showed similar wear resistance to CAD/CAM composite resins, the wear resistance of all the indirect composite resins was higher than that of bis-acryl base provisional and polymethyl methacrylate resins.
Abstract
PURPOSE. The aim of this study was to investigate simulated localized and generalized wear of indirect composite resins used for implant supported provisional restorations. MATERIALS AND METHODS. The study investigated ten indirect composite resins. Two kinds of wear were simulated by 400,000 cycles in a Leinfelder-Suzuki (Alabama) machine. Localized wear was simulated with a stainless-steel ball bearing antagonist and generalized with a flat-ended stainless-steel cylinder antagonist. The tests were carried out in water slurry of polymethyl methacrylate beads. Wear was measured using a Proscan 2100 noncontact profilometer in conjunction with Proscan and AnSur 3D software. RESULTS. Both localized and generalized wear were significantly different (P<.05) among the indirect composite resins. SR Nexco and Gradia Plus showed significantly less wear than the other indirect composite resins. The rank order of wear was same in both types of wear simulation. CONCLUSION. Indirect composite resins are recommended when a provisional implantsupported restoration is required to function in place over a long period. Although only some indirect composite resins showed similar wear resistance to CAD/CAM composite resins, the wear resistance of all the indirect composite resins was higher than that of bis-acryl base provisional and polymethyl methacrylate resins.
참고문헌 (24)
- Pjetursson BE, "Improvements in implant dentistry over the last decade : comparison of survival and complication rates in older and newer publications", Int J Oral Maxillofac Implants, 29, pp.308~324 (2014)
- Slagter KW, "Immediate placement of dental implants in the esthetic zone : a systematic review and pooled analysis", J Periodontol, 85, pp.e241~50 (2014)
- Hartlev J, "Patient satisfaction and esthetic outcome after immediate placement and provisionalization of single-tooth implants involving a definitive individual abutment", Clin Oral Implants Res, 25, pp.1245~1250 (2014)
- Yan Q, "Soft and hard tissue changes following immediate placement or immediate restoration of single-tooth implants in the esthetic zone : A systematic review and meta-analysis", Int J Oral Maxillofac Implants, 31, pp.1327~1340 (2016)
- Bishti S, "Effect of the implant-abutment interface on peri-implant tissues : a systematic review", Acta Odontol Scand, 72, pp.13~25 (2014)
- Chen ST, "Esthetic outcomes following immediate and early implant placement in the anterior maxillaa systematic review", Int J Oral Maxillofac Implants, 29, pp.186~215 (2014)
- Weigl P, "The impact of immediately placed and restored single-tooth implants on hard and soft tissues in the anterior maxilla", Eur J Oral Implantol, 9, pp.S89~106 (2016)
- Santing HJ, "Occlusal wear of provisional implant-supported restorations", Clin Implant Dent Relat Res, 17, pp.179~185 (2015)
- Tarnow DP, "Preservation of implant esthetics : soft tissue and restorative considerations", J Esthet Dent, 8, pp.12~19 (1996)
- Chee WW, "Provisional restorations in soft tissue management around dental implants", Periodontol 2000, 27, pp.139~147 (2001)
- Belser UC, "Prosthetic management of the partially dentate patient with fixed implant restorations", Clin Oral Implants Res, 11, pp.126~145 (2000)
- Burns DR, "A review of selected dental literature on contemporary provisional fixed prosthodontic treatment : report of the Committee on Research in Fixed Prosthodontics of the Academy of Fixed Prosthodontics", J Prosthet Dent, 90, pp.474~497 (2003)
- Castellon P, "Techniques to facilitate provisionalization of implant restorations", J Oral Maxillofac Surg, 63, pp.72~79 (2005)
- Shibasaki S, "Influence of different curing modes on polymerization behavior and mechanical properties of dual-cured provisional resins", Oper Dent, 42, pp.526~536 (2017)
- Abdullah AO, "Comparison between direct chairside and digitally fabricated temporary crowns", Dent Mater J, 37, pp.957~963 (2018)
- Takamizawa T, "Mechanical properties and simulated wear of provisional resin materials", Oper Dent, 40, pp.603~613 (2015)
- Tsujimoto A, "Wear of resin composites : Current insights into underlying mechanisms, evaluation methods and influential factors", Jpn Dent Sci Rev, 54, pp.76~87 (2018)
- ISO Standards, "ISO14569 Dental materials - Guidance on testing of wear - Part 2: Wear by two- and", or three-body contact, 1, 2001, pp.1~31
- Leinfelder KF, "In vitro wear device for determining posterior composite wear", J Am Dent Assoc, 130, pp.1347~1353 (1999)
- Barkmeier WW, "Localized and generalized simulated wear of resin composites", Oper Dent, 40, pp.322~335 (2015)
- Heintze SD, "Wear of dental materials : Clinical significance and laboratory wear simulation methods A review", Dent Mater J, 38, pp.343~353 (2019)
- Tsujimoto A, "Influence of thermal stress on simulated localized and generalized wear of nanofilled resin composites", Oper Dent, 43, pp.380~390 (2018)
- Tsujimoto A, "Influence of thermal cycling on flexural properties and simulated wear of computer-aided design", computer-aided manufacturing resin composites, 2017, pp.42, 101~110
- Barkmeier WW, "Comparison of laboratory and clinical wear rates of resin composites", Quintessence Int, 35, pp.269~274 (2004)
