본문 바로가기
KERD
논문KCI 등재

Effects of type of magnet attachment and implant angulation in two implant overdenture models

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

PURPOSE. The purpose of this study is to evaluate the effects of type of magnet attachment and implant angulation in two implant overdenture models. MATERIALS AND METHODS. Magnet attachments used in this study were flat and dome types (MGT5515, MGT5520D, Dentium Co., Seoul, Korea). Two implants with keepers were inserted in the resin blocks at a distance of 24 mm. For the first model, the implants were parallel to the vertical and perpendicular to the horizontal; for the second model, both were angulated 5 degrees to the mesial; for the third model, both were angulated 10 degrees toward the mesial. The retentive force was measured in both vertical and lateral directions. Statistical analyses were performed using SPSS software version 22.0 (α=.05). RESULTS. The flat type magnet attachment showed the highest lateral retentive force in the 20° divergent group (P<.05) and the dome type magnet attachment showed the highest lateral retentive force in the parallel group (P<.05). The vertical and lateral retentive force of the dome type magnet attachment was greater than that of the flat type magnet attachment in every direction (P<.05). CONCLUSION. Within the limitations of this study, the dome shape magnet attachment can resist vertical and lateral retentive force more superiorly than the flat type magnet attachment, regardless of angle, in the mandibular two implant model.

Abstract

PURPOSE. The purpose of this study is to evaluate the effects of type of magnet attachment and implant angulation in two implant overdenture models. MATERIALS AND METHODS. Magnet attachments used in this study were flat and dome types (MGT5515, MGT5520D, Dentium Co., Seoul, Korea). Two implants with keepers were inserted in the resin blocks at a distance of 24 mm. For the first model, the implants were parallel to the vertical and perpendicular to the horizontal; for the second model, both were angulated 5 degrees to the mesial; for the third model, both were angulated 10 degrees toward the mesial. The retentive force was measured in both vertical and lateral directions. Statistical analyses were performed using SPSS software version 22.0 (α=.05). RESULTS. The flat type magnet attachment showed the highest lateral retentive force in the 20° divergent group (P<.05) and the dome type magnet attachment showed the highest lateral retentive force in the parallel group (P<.05). The vertical and lateral retentive force of the dome type magnet attachment was greater than that of the flat type magnet attachment in every direction (P<.05). CONCLUSION. Within the limitations of this study, the dome shape magnet attachment can resist vertical and lateral retentive force more superiorly than the flat type magnet attachment, regardless of angle, in the mandibular two implant model.

참고문헌 (16)

  1. Moghadam BK, "Magnetic retention for overdentures", J Prosthet Dent, 41, pp.26~29 (1979)
  2. Gillings BR, "Magnetic retention for overdentures. Part II", J Prosthet Dent, 49, pp.607~618 (1983)
  3. Feine JS, "The McGill Consensus Statement on Overdentures. Montreal, Quebec, Canada. May 24-25, 2002", Int J Prosthodont, 15, pp.413~414 (2002)
  4. Thomason JM, "Mandibular two implant-supported overdentures as the first choice standard of care for edentulous patients-the York Consensus Statement", Br Dent J, 207, pp.185~186 (2009)
  5. Takeshita S, "Stress analysis of mandibular two-implant overdenture with different attachment systems", Dent Mater J, 30, pp.928~934 (2011)
  6. Chopra V, "Breakaway forces of flat and domed surfaced Magfit implant magnet attachments", Eur J Prosthodont Restor Dent, 15, pp.7~12 (2007)
  7. Riley MA, "Magnets in prosthetic dentistry", J Prosthet Dent, 86, pp.137~142 (2001)
  8. Yang TC, "Attachment systems for implant overdenture : influence of implant inclination on retentive and lateral forces", Clin Oral Implants Res, 22, pp.1315~1319 (2011)
  9. Rabbani S, "Investigation of retentive force reduction and wear of the locator attachment system with different implant angulations", Int J Oral Maxillofac Implants, 30, pp.556~563 (2015)
  10. Boeckler AF, "Mechanical properties of magnetic attachments for removable prostheses on teeth and implants", J Prosthodont, 17, pp.608~615 (2008)
  11. Uludag B, "Effects of implant angulations and attachment configurations on the retentive forces of locator attachment-retained overdentures", Int J Oral Maxillofac Implants, 29, pp.1053~1057 (2014)
  12. "ISO 13017:2012/AMD 1:2015. Dentistry - Magnetic attachments - Amendant 1" (2015)[URL]
  13. Lahori M, "Comparative evaluation of bone in mandibular implant retained overdentures using delayed and immediate loading protocol : an in-vivo study", J Indian Prosthodont Soc, 13, pp.113~121 (2013)
  14. Cristache CM, "Five-year clinical trial using three attachment systems for implant overdentures", Clin Oral Implants Res, 25, pp.e171~e178 (2014)
  15. Koole S, "Contemporary undergraduate implant dentistry education : a systematic review", Eur J Dent Educ, 18, pp.11~23 (2014)
  16. 이은지, "The influence of the number and the type of magnetic attachment on the retention of mandibular mini implant overdenture", The Journal of Advanced of Prosthodontics, 9(1), pp.14~21 (2017), 대한치과보철학회[DOI]

관련 논문AI추천

The influence of the number and the type of magnetic attachment on the retention of mandibular mini implant overdenture신수연, 이은지대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제1호A study on the changes in attractive force of magnetic attachments for overdenture이종혁, 임한울, 조인호, 최유성대한치과보철학회 · The Journal of Advanced of Prosthodontics2016 · 제8권 제1호자성 어태치먼트의 형태와 수에 따른 하악 임플란트 피개의치의 유지력에 대한 비교연구서민지, 이준석, 조인호대한턱관절교합학회 · 구강회복응용과학지2008 · 제24권 제2호A comparative study on the dislodging force of magnetic attachment to the denture resin by magnetic design and fixing materials이정화, 이종혁, 조인호대한치과보철학회 · 대한치과보철학회지2008 · 제46권 제3호Effect of abutment angulation in the retention and durability of three overdenture attachment systems: An in vitro studyAna Cristina Braga, Antonio Sergio Silva, Carlos Aroso, Esther Berastegui, Jose Manuel Mendes, Raul Ustrell, Tomas Escuin대한치과보철학회 · The Journal of Advanced of Prosthodontics2016 · 제8권 제1호Effects of overdenture attachment systems with different working principles on stress transmission: A three-dimensional finite element studyNurullah Turker, Ulviye Sebnem Buyukkaplan대한치과보철학회 · The Journal of Advanced of Prosthodontics2020 · 제12권 제6호

이 간행물의 다른 논문 (5건)