본문 바로가기
KERD
논문KCI 등재

Effect of two-phase fabrication method for the optimum fit of light-polymerized record bases

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

PURPOSE. The aims of this study were to suggest a method of fabrication of the record base using a light-polymerized resin by applying the two-phase fabrication method for the improvement of the fit of the record base and to compare the degree of fit according to the separation site. MATERIALS AND METHODS. In the edentulous cast of maxilla, four test groups were considered. In the first, second, third, and fourth test groups (n = 12 in each group) the separation was done at 0, 5, 10, and 15 mm, respectively below the alveolar crest along the palatal plane. For the control group, the record base was made without separating the two sections. The light-body silicone material was injected into the fitting surface of the record base. It was then placed onto the cast and finger pressure was applied to stabilize it in a seated position followed by immediate placement onto the universal test device. Finally, the mass of the impression material was measured after it was removed. ANOVA was performed using the SAS program. For the post-hoc test, the Wilcoxon Rank-Sum test and the Tukey-Kramer HSD test were performed (α= 0.05). RESULTS. The control group and Group 3, 4 showed significant differences. The Group 3 and 4 showed significantly smaller inside gaps than the control group which was not made with the two-phase fabrication method. CONCLUSION. The two-stage polymerized technique can improve the fit of the denture base particularly when the separation was made at 10 to 15 mm from the alveolar crest.

Abstract

PURPOSE. The aims of this study were to suggest a method of fabrication of the record base using a light-polymerized resin by applying the two-phase fabrication method for the improvement of the fit of the record base and to compare the degree of fit according to the separation site. MATERIALS AND METHODS. In the edentulous cast of maxilla, four test groups were considered. In the first, second, third, and fourth test groups (n = 12 in each group) the separation was done at 0, 5, 10, and 15 mm, respectively below the alveolar crest along the palatal plane. For the control group, the record base was made without separating the two sections. The light-body silicone material was injected into the fitting surface of the record base. It was then placed onto the cast and finger pressure was applied to stabilize it in a seated position followed by immediate placement onto the universal test device. Finally, the mass of the impression material was measured after it was removed. ANOVA was performed using the SAS program. For the post-hoc test, the Wilcoxon Rank-Sum test and the Tukey-Kramer HSD test were performed (α= 0.05). RESULTS. The control group and Group 3, 4 showed significant differences. The Group 3 and 4 showed significantly smaller inside gaps than the control group which was not made with the two-phase fabrication method. CONCLUSION. The two-stage polymerized technique can improve the fit of the denture base particularly when the separation was made at 10 to 15 mm from the alveolar crest.

참고문헌 (9)

  1. Nishigawa G, "Record base for an edentulous maxillary arch with severe undercuts in the labial aspect of the anterior residual ridge", J Prosthet Dent, 87, pp.99~101 (2002)
  2. Boberick KG, "Dimensional stability of record bases fabricated from light-polymerized composite using two methods", J Prosthet Dent, 79, pp.399~403 (1998)
  3. Elahi JM, "Effect of different polymerization techniques on dimensional stability of record bases", J Prosthet Dent, 71, pp.150~153 (1994)
  4. Takamata T, "Resin denture bases:review of accuracy and methods of polymerization", Int J Prosthodont, 2, pp.555~62 (1989)
  5. Sykora O, "Posterior palatal seal adaptation:influence of processing technique,palate shape and immersion", J Oral Rehabil, 20, pp.19~31 (1993)
  6. Oh WS, "Two-stage technique for optimum fit and stability of light-polymerized record bases", J Prosthet Dent, 99, pp.410~411 (2008)
  7. Kim Y, "Effect of relining method on dimensional accuracy of posterior palatal seal.An in vitro study", J Prosthodont, 17, pp.211~218 (2008)
  8. Consani RL, "Effect of commercial acrylic resins on dimensional accuracy of the maxillary denture base", Braz Dent J, 13, pp.57~60 (2002)
  9. Takamata T, "Adaptation of acrylic resin dentures as influenced by the activation mode of polymerization", J Am Dent Assoc, 119, pp.271~276 (1989)

관련 논문AI추천

Effect of polymerization method and fabrication method on occlusal vertical dimension and occlusal contacts of complete-arch prosthesisAna Christina Claro Neves, Ana Paula Barbosa Lima, Lais Regiane da Silva Concilio, Marina Amaral, Rafael Pino Vitti대한치과보철학회 · The Journal of Advanced of Prosthodontics2018 · 제10권 제2호Flexural properties of a light-cure and a self-cure denture base materials compared to conventional alternativesAltug Cilingir, Burc Gencel, Emre Mumcu, Tonguc Su¨lu¨n대한치과보철학회 · The Journal of Advanced of Prosthodontics2011 · 제3권 제3호Three dimensional deformation of dry-stored complete denture base at room temperature이준석, 임서련대한치과보철학회 · The Journal of Advanced of Prosthodontics2016 · 제8권 제4호Analysis of the trueness and precision of complete denture bases manufactured using digital and analog technologiesAngela Montanari, Laura Anderlucci, Leonardo Ciocca, Lorenzo Breschi, Mattia Maltauro, Roberto Meneghello, Valerio Cimini대한치과보철학회 · The Journal of Advanced of Prosthodontics2023 · 제15권 제1호Effects of relining materials on the flexural strength of relined thermoplastic denture base resins류재준, 박진홍, 선윤한, 송소연, 이기선, 이정열대한치과보철학회 · The Journal of Advanced of Prosthodontics2018 · 제10권 제5호Comparing accuracy of denture bases fabricated by injection molding, CAD/CAM milling, and rapid prototyping method권긍록, 노관태, 배아란, 백장현, 홍성진, Suji Lee대한치과보철학회 · The Journal of Advanced of Prosthodontics2019 · 제11권 제1호

이 간행물의 다른 논문 (9건)