PURPOSE. The aim of this study was to investigate a comparison of implant bone bed preparation with Er,Cr:YSGG laser and conventional drills on the relationship between implant stability quotient (ISQ) values and implant insertion variables. MATERIALS AND METHODS. Forty implants were inserted into two different types of pig rib bone. One group was prepared with conventional drills and a total of 20 implants were inserted into type I and type II bone. The other group was prepared with a Er,Cr:YSGG laser and a total of 20 implants were inserted into type I and type II bone. ISQ, maximum insertion torque, angular momentum, and insertion torque energy values were measured. RESULTS. The mean values for variables were significantly higher in type I bone than in type II bone (P < .01). In type I bone, the ISQ values in the drill group were significantly higher than in the laser group (P < .05). In type II bone, the ISQ values in the laser group were significantly higher than in the drill group (P < .01). In both type I and type II bone, the maximum insertion torque, total energy, and total angular momentum values between the drill and laser groups did not differ significantly (P ≥ .05). The ISQ values were correlated with maximum insertion torque (P < .01, r = .731), total energy (P < .01, r = .696), and angular momentum (P < .01, r = .696). CONCLUSION. Within the limitations of this study, the effects of bone bed preparation with Er,Cr:YSGG laser on the relationship between implant stability quotient (ISQ) values and implant insertion variables were comparable to those of drilling.

Abstract

PURPOSE. The aim of this study was to investigate a comparison of implant bone bed preparation with Er,Cr:YSGG laser and conventional drills on the relationship between implant stability quotient (ISQ) values and implant insertion variables. MATERIALS AND METHODS. Forty implants were inserted into two different types of pig rib bone. One group was prepared with conventional drills and a total of 20 implants were inserted into type I and type II bone. The other group was prepared with a Er,Cr:YSGG laser and a total of 20 implants were inserted into type I and type II bone. ISQ, maximum insertion torque, angular momentum, and insertion torque energy values were measured. RESULTS. The mean values for variables were significantly higher in type I bone than in type II bone (P < .01). In type I bone, the ISQ values in the drill group were significantly higher than in the laser group (P < .05). In type II bone, the ISQ values in the laser group were significantly higher than in the drill group (P < .01). In both type I and type II bone, the maximum insertion torque, total energy, and total angular momentum values between the drill and laser groups did not differ significantly (P ≥ .05). The ISQ values were correlated with maximum insertion torque (P < .01, r = .731), total energy (P < .01, r = .696), and angular momentum (P < .01, r = .696). CONCLUSION. Within the limitations of this study, the effects of bone bed preparation with Er,Cr:YSGG laser on the relationship between implant stability quotient (ISQ) values and implant insertion variables were comparable to those of drilling.

참고문헌 (29)

  1. Adell R, "A 15-year study of osseointegrated implants in the treatment of the edentulous jaw", Int J Oral Surg, 10, pp.387~416 (1981)
  2. Albrektsson T, "Osseointegrated titanium implants.Requirements for ensuring a long-lasting,direct bone-to-implant anchorage in man", Acta Orthop Scand, 52, pp.155~170 (1981)
  3. Meredith N, "Assessment of implant stability as a prognostic determinant", Int J Prosthodont, 11, pp.491~501 (1998)
  4. Friberg B, "Stability measurements of one-stage Bra􀆆nemark implants during healing in mandibles.A clinical resonance frequency analysis study", Int J Oral Maxillofac Surg, 28, pp.266~272 (1999)
  5. Meredith N, "A review of nondestructive test methods and their application to measure the stability and osseointegration of bone anchored endosseous implants", Crit Rev Biomed Eng, 26, pp.275~291 (1998)
  6. Friberg B, "A comparison between cutting torque and resonance frequency measurements of maxillary implants.A 20-month clinical study", Int J Oral Maxillofac Surg, 28, pp.297~303 (1999)
  7. Meredith N, "Resonance frequency measurements of implant stability in vivo.A crosssectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla", Clin Oral Implants Res, 8, pp.226~233 (1997)
  8. Meredith N, "Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis", Clin Oral Implants Res, 7, pp.261~267 (1996)
  9. Barewal RM, "Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface", Int J Oral Maxillofac Implants, 18, pp.641~651 (2003)
  10. O’Sullivan D, "Measurements comparing the initial stability of five designs of dental implants:a human cadaver study", Clin Implant Dent Relat Res, 2, pp.85~92 (2000)
  11. da Cunha HA, "A comparison between cutting torque and resonance frequency in standard and TiUnite single-tooth implants under immediate loading", Int J Oral Maxillofac Implants, 19, pp.578~585 (2004)
  12. Kim SH, "Rotational resistance of surface-treated mini-implants", Angle Orthod, 79, pp.899~907 (2009)
  13. 김성균, "Development of predictable stability test for assessment of optimum loading time in dental implant", 대한치과보철학회지, 46(6), pp.628~633 (2008), 대한치과보철학회
  14. Li ZZ, "Bone ablation with Er:YAG and CO2 laser:study of thermal and acoustic effects", Lasers Surg Med, 12, pp.79~85 (1992)
  15. Buchelt M, "Erb:YAG and Hol:YAG laser osteotomy:the effect of laser ablation on bone healing", Lasers Surg Med, 15, pp.373~381 (1994)
  16. Friesen LR, "Laser irradiation of bone:II.Healing response following treatment by CO2 and Nd:YAG lasers", J Periodontol, 70, pp.75~83 (1999)
  17. Walsh LJ, "The current status of laser applications in dentistry", Aust Dent J, 48, pp.146~155 (2003)
  18. Featherstone JD, "Caries detection and prevention with laser energy", Dent Clin North Am, 44, pp.955~969 (2000)
  19. Eversole LR, "Preliminary investigations on the utility of an erbium,chromium YSGG laser", J Calif Dent Assoc, 23, pp.41~47 (1995)
  20. Kimura Y, "Effects of erbium,chromium:YSGG laser irradiation on canine mandibular bone", J Periodontol, 72, pp.1178~1182 (2001)
  21. Wang X, "Morphological changes of bovine mandibular bone irradiated by Er,Cr:YSGG laser:an in vitro study", J Clin Laser Med Surg, 20, pp.245~250 (2002)
  22. Wang X, "In vivo study of the healing processes that occur in the jaws of rabbits following perforation by an Er,Cr:YSGG laser", Lasers Med Sci, 20, pp.21~27 (2005)
  23. Lewandrowski KU, "Use of the Er:YAG laser for improved plating in maxillofacial surgery:comparison of bone healing in laser and drill osteotomies", Lasers Surg Med, 19, pp.40~45 (1996)
  24. Sennerby L, "A morphometric and biomechanic comparison of titanium implants inserted in rabbit cortical and cancellous bone", Int J Oral Maxillofac Implants, 7, pp.62~71 (1992)
  25. O’Sullivan D, "Influence of implant taper on the primary and secondary stability of osseointegrated titanium implants", Clin Oral Implants Res, 15, pp.474~480 (2004)
  26. O¨stman PO, "Resonance frequency analysis measurements of implants at placement surgery", Int J Prosthodont, 19, pp.77~83 (2006)
  27. O’Sullivan D, "A comparison of two methods of enhancing implant primary stability", Clin Implant Dent Relat Res, 6, pp.48~57 (2004)
  28. Sasaki KM, "Scanning electron microscopy and Fourier transformed infrared spectroscopy analysis of bone removal using Er:YAG and CO2 lasers", J Periodontol, 73, pp.643~652 (2002)
  29. Schwarz F, "Influence of implant bed preparation using an Er:YAG laser on the osseointegration of titanium implants:a histomorphometrical study in dogs", J Oral Rehabil, 34, pp.273~281 (2007)

관련 논문AI추천

Effects of the Er,Cr:YSGG laser on bone bed preparation with various laser tips곽재영, 김성균, 이신재, 이주희, 허성주, 홍성두대한치과보철학회 · 대한치과보철학회지2008 · 제46권 제3호Effect of bone quality and implant surgical technique on implant stability quotient (ISQ) value곽재영, 김성균, 윤홍기, 이수영, 허성주대한치과보철학회 · The Journal of Advanced of Prosthodontics2011 · 제3권 제1호Evaluation of the correlation between insertion torque and primary stability of dental implants using a block bone test구영, 구기태, 김명덕, 김병국, 김성태, 김태일, 님궁희, 류인철, 설양조, 이용무, 이은희, Dorjpalam Bayarchimeg대한치주과학회 · Journal of Periodontal & Implant Science2013 · 제43권 제1호The effect of various thread designs on the initial stability of taper implants권호범, 김명주, 박주희, 임영준대한치과보철학회 · The Journal of Advanced of Prosthodontics2009 · 제1권 제1호The relationship between initial implant stability quotient values and bone-to-implant contact ratio in the rabbit tibia김성균, 박인필, 이신재, 이주희대한치과보철학회 · The Journal of Advanced of Prosthodontics2011 · 제3권 제2호Clinical outcome of immediately and early loaded implants with laser treated surface: a 3-year retrospective study서진호, 이성복, 조성암대한치과보철학회 · The Journal of Advanced of Prosthodontics2018 · 제10권 제2호

이 간행물의 다른 논문 (6건)