본문 바로가기
KERD
논문KCI 등재

Effects of the Er,Cr:YSGG laser on bone bed preparation with various laser tips

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

STATEMENT OF PROBLEM: Preparation of implant beds with lasers is considered a safe and reliable method, but the accuracy of this technique has not been examined. PURPOSE: The purpose of this study was to evaluate the accuracy and effectiveness of implant bed preparation using an Er,Cr:YSGG laser. MATERIAL AND METHODS: An Er,Cr:YSGG laser was applied to pig rib bone. The laser was employed at a 5.75 W power setting, 30 Hz/sec pulse repetition, and 70 μs pulse duration with 50 % water and 60% air spray. According to laser tips the groups were divided as follows; Group 1: paralleled - shaped sapphire tip (0.6 mmФ), Group 2: paralleled - shaped zirconia tip (0.6 mmФ), Group 3: tapered sapphire tip (0.4 mmФ). The Er,Cr:YSGG laser tip was separated by 1 mm from the bone and applied for 15 seconds in a non-contact mode. After the application, the bone was sectioned for specimens. Histologic measurements were determined by computerized morphometry. The length of the prepared bone surface was measured and the width of the entrance was measured. The results were analyzed with one-way ANOVA (P<0.05). RESULTS: The prepared length of group 3 was longer than that of group 2. The prepared bone width was larger than the width of the laser tip in every group. Additional bone removal was observed adjacent to the prepared area and displayed an irregular surface. CONCLUSION & DISCUSSION: Different cutting effects were observed according to the laser tip, emphasizing the importance of proper tip selection in the clinical setting. This preliminary study supported the existence of hydrokinetic effects.

Abstract

STATEMENT OF PROBLEM: Preparation of implant beds with lasers is considered a safe and reliable method, but the accuracy of this technique has not been examined. PURPOSE: The purpose of this study was to evaluate the accuracy and effectiveness of implant bed preparation using an Er,Cr:YSGG laser. MATERIAL AND METHODS: An Er,Cr:YSGG laser was applied to pig rib bone. The laser was employed at a 5.75 W power setting, 30 Hz/sec pulse repetition, and 70 μs pulse duration with 50 % water and 60% air spray. According to laser tips the groups were divided as follows; Group 1: paralleled - shaped sapphire tip (0.6 mmФ), Group 2: paralleled - shaped zirconia tip (0.6 mmФ), Group 3: tapered sapphire tip (0.4 mmФ). The Er,Cr:YSGG laser tip was separated by 1 mm from the bone and applied for 15 seconds in a non-contact mode. After the application, the bone was sectioned for specimens. Histologic measurements were determined by computerized morphometry. The length of the prepared bone surface was measured and the width of the entrance was measured. The results were analyzed with one-way ANOVA (P<0.05). RESULTS: The prepared length of group 3 was longer than that of group 2. The prepared bone width was larger than the width of the laser tip in every group. Additional bone removal was observed adjacent to the prepared area and displayed an irregular surface. CONCLUSION & DISCUSSION: Different cutting effects were observed according to the laser tip, emphasizing the importance of proper tip selection in the clinical setting. This preliminary study supported the existence of hydrokinetic effects.

참고문헌 (20)

  1. Walsh LJ, "The current status of laser applications in dentistry", Aust Dent J, 48, pp.146~155 (2003)
  2. van As G, "Erbium lasers in dentistry", Dent Clin N Am, 48, pp.1017~1059 (2004)
  3. Eyrich G, "Hard-tissue drilling and cutting with a 9.6 um CO2 laser" (2004), Med Habililationsschrift
  4. Ivanenko M, "In vivo animal trials with a scanning CO2 laser osteotome", Lasers Surg Med, 37, pp.144~148 (2005)
  5. Aoki A, "Lasers in nonsurgical periodontal therapy", Periodontol 2000, 36, pp.59~97 (2004)
  6. Eriksson A, "Temperature threshold levels for heat-induced bone tissue injury. A vital microscoping study in the rabbit", J Prosthet Dent, 50, pp.101~107 (1983)
  7. Kimura Y, "Effects of erbium, chromium:YSGG laser irradiation on canine mandibular bone", J Periodontol, 72, pp.1178~1182 (2001)
  8. Sasaki KM, "Scanning electron microscopy and Fourier transformed infrared spectroscopy analysis of bone removal using Er:YAG and CO2 lasers", J Periodontol, 73, pp.643~652 (2002)
  9. Sasaki KM, "Ultrastructural analysis of bone tissue irradiated by Er:YAG laser", Lasers Surg Med, 31, pp.322~332 (2002)
  10. Salina S, "Histological evaluation, in rabbit tibiae, of osseointegration of mini-implants in sites prepared with Er:YAG laser versus sites prepared with traditional burs", J Long Term Eff Med Implants, 16, pp.145~156 (2006)
  11. Schwarz F, "Influence of implant bed preparation using an Er:YAG laser on the osseointegration of titanium im-plants: a histomorphometrical study in dogs", J Oral Rehabil, 34, pp.273~281 (2007)
  12. Kesler G, "Use of Er:YAG laser to improve osseointegration of titanium alloy implant-a comparison of bone healing", Int J Oral Maxillofac Implants, 21, pp.375~379 (2006)
  13. el-Montaser M, "Osseointegration of titanium implant in erbium- YAG laser-prepared bone", Implant Dent, 8, pp.79~85 (1999)
  14. Rizoiu IM, "New laser-matter interaction concept to enhance hard tissue cutting efficiency", Laser-Tissue Interaction, 2134A, pp.309~317 (1994)
  15. Hossain M, "Effects of Er,Cr:YSGG laser irradiation in human enamel and dentin: ablation and morphological studies", Journal of Clinical Laser Medicine and Surgery, 17, pp.155~ (1999)
  16. Eversole LR, "Preliminary investigations on the utility of an erbium, chromium:YSGG laser", J Calif Dent Assoc, 23, pp.41~47 (1995)
  17. Aoki A, "Comparative study of Er:YAG laser and rotating bur for bone ablation: SEM and longterm histological examinations", Lasers in Dentistry, pp.389~391 (2003)
  18. Wang X, "Morpholgoical changes of bovine mandibular bone irradiated by Er,Cr:YSGG laser: an in vitro study", J Clin Laser Med Surg, 20, pp.245~250 (2002)
  19. Wang X, "In vivo study of the healing processes that occur in the jaws of rabbits following perforation by an Er,Cr:YSGG laser", Lasers Med Sci, 20, pp.21~27 (2005)
  20. Riziou I, "Atomized fluid particles for electromagnertically induced cutting. US patent 5,741,247", US patent, ~ (1998)

관련 논문AI추천

A comparison of bone bed preparation with laser and conventional drill on the relationship between implant stability quotient (ISQ) values and implant insertion variables곽재영, 권호범, 김명주, 김성균, 김태형, 박춘매, 이수영, 이주희, 허성주대한치과보철학회 · The Journal of Advanced of Prosthodontics2010 · 제2권 제4호The effect of Er:YAG laser irradiation on the surface microstructure and roughness of hydroxyapatite-coated implant허익, 권영혁, 김성원, 신승일, 정종혁대한치주과학회 · Journal of Periodontal & Implant Science2011 · 제40권 제6호Effect of erbium-doped: yttrium, aluminium and garnet laser irradiation on the surface microstructure and roughness of sand-blasted, large grit, acid-etched implants허익, 권영혁, 신승일, 이지훈, 정종혁대한치주과학회 · Journal of Periodontal & Implant Science2011 · 제41권 제3호Effect of erbium-doped yttrium-aluminum-garnet laser on surface characteristics and biocompatibility of resorbable blast media titanium김보현, 김영준, 엄소원, 이인석치의학연구원 · Oral Biology Research2021 · 제45권 제2호The effect of erbium-doped: yttrium, aluminium and garnet laser irradiation on the surface microstructure and roughness of double acidetched implants허익, 권영혁, 김지현, 신승일, 정종혁대한치주과학회 · Journal of Periodontal & Implant Science2011 · 제41권 제5호Er:YAG 레이저 조사가 산화 티타늄 블라스팅 임플란트 표면 미세 구조 및 거칠기에 미치는 영향허익, 권영혁, 박준봉, 안장혁, 정종혁대한치주과학회 · Journal of Periodontal & Implant Science2008 · 제38권 제1호

이 간행물의 다른 논문 (9건)