Effects of the Er,Cr:YSGG laser on bone bed preparation with various laser tips
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
STATEMENT OF PROBLEM: Preparation of implant beds with lasers is considered a safe and reliable method, but the accuracy of this technique has not been examined. PURPOSE: The purpose of this study was to evaluate the accuracy and effectiveness of implant bed preparation using an Er,Cr:YSGG laser. MATERIAL AND METHODS: An Er,Cr:YSGG laser was applied to pig rib bone. The laser was employed at a 5.75 W power setting, 30 Hz/sec pulse repetition, and 70 μs pulse duration with 50 % water and 60% air spray. According to laser tips the groups were divided as follows; Group 1: paralleled - shaped sapphire tip (0.6 mmФ), Group 2: paralleled - shaped zirconia tip (0.6 mmФ), Group 3: tapered sapphire tip (0.4 mmФ). The Er,Cr:YSGG laser tip was separated by 1 mm from the bone and applied for 15 seconds in a non-contact mode. After the application, the bone was sectioned for specimens. Histologic measurements were determined by computerized morphometry. The length of the prepared bone surface was measured and the width of the entrance was measured. The results were analyzed with one-way ANOVA (P<0.05). RESULTS: The prepared length of group 3 was longer than that of group 2. The prepared bone width was larger than the width of the laser tip in every group. Additional bone removal was observed adjacent to the prepared area and displayed an irregular surface. CONCLUSION & DISCUSSION: Different cutting effects were observed according to the laser tip, emphasizing the importance of proper tip selection in the clinical setting. This preliminary study supported the existence of hydrokinetic effects.
Abstract
STATEMENT OF PROBLEM: Preparation of implant beds with lasers is considered a safe and reliable method, but the accuracy of this technique has not been examined. PURPOSE: The purpose of this study was to evaluate the accuracy and effectiveness of implant bed preparation using an Er,Cr:YSGG laser. MATERIAL AND METHODS: An Er,Cr:YSGG laser was applied to pig rib bone. The laser was employed at a 5.75 W power setting, 30 Hz/sec pulse repetition, and 70 μs pulse duration with 50 % water and 60% air spray. According to laser tips the groups were divided as follows; Group 1: paralleled - shaped sapphire tip (0.6 mmФ), Group 2: paralleled - shaped zirconia tip (0.6 mmФ), Group 3: tapered sapphire tip (0.4 mmФ). The Er,Cr:YSGG laser tip was separated by 1 mm from the bone and applied for 15 seconds in a non-contact mode. After the application, the bone was sectioned for specimens. Histologic measurements were determined by computerized morphometry. The length of the prepared bone surface was measured and the width of the entrance was measured. The results were analyzed with one-way ANOVA (P<0.05). RESULTS: The prepared length of group 3 was longer than that of group 2. The prepared bone width was larger than the width of the laser tip in every group. Additional bone removal was observed adjacent to the prepared area and displayed an irregular surface. CONCLUSION & DISCUSSION: Different cutting effects were observed according to the laser tip, emphasizing the importance of proper tip selection in the clinical setting. This preliminary study supported the existence of hydrokinetic effects.
참고문헌 (20)
- Walsh LJ, "The current status of laser applications in dentistry", Aust Dent J, 48, pp.146~155 (2003)
- van As G, "Erbium lasers in dentistry", Dent Clin N Am, 48, pp.1017~1059 (2004)
- Eyrich G, "Hard-tissue drilling and cutting with a 9.6 um CO2 laser" (2004), Med Habililationsschrift
- Ivanenko M, "In vivo animal trials with a scanning CO2 laser osteotome", Lasers Surg Med, 37, pp.144~148 (2005)
- Aoki A, "Lasers in nonsurgical periodontal therapy", Periodontol 2000, 36, pp.59~97 (2004)
- Eriksson A, "Temperature threshold levels for heat-induced bone tissue injury. A vital microscoping study in the rabbit", J Prosthet Dent, 50, pp.101~107 (1983)
- Kimura Y, "Effects of erbium, chromium:YSGG laser irradiation on canine mandibular bone", J Periodontol, 72, pp.1178~1182 (2001)
- Sasaki KM, "Scanning electron microscopy and Fourier transformed infrared spectroscopy analysis of bone removal using Er:YAG and CO2 lasers", J Periodontol, 73, pp.643~652 (2002)
- Sasaki KM, "Ultrastructural analysis of bone tissue irradiated by Er:YAG laser", Lasers Surg Med, 31, pp.322~332 (2002)
- Salina S, "Histological evaluation, in rabbit tibiae, of osseointegration of mini-implants in sites prepared with Er:YAG laser versus sites prepared with traditional burs", J Long Term Eff Med Implants, 16, pp.145~156 (2006)
- Schwarz F, "Influence of implant bed preparation using an Er:YAG laser on the osseointegration of titanium im-plants: a histomorphometrical study in dogs", J Oral Rehabil, 34, pp.273~281 (2007)
- Kesler G, "Use of Er:YAG laser to improve osseointegration of titanium alloy implant-a comparison of bone healing", Int J Oral Maxillofac Implants, 21, pp.375~379 (2006)
- el-Montaser M, "Osseointegration of titanium implant in erbium- YAG laser-prepared bone", Implant Dent, 8, pp.79~85 (1999)
- Rizoiu IM, "New laser-matter interaction concept to enhance hard tissue cutting efficiency", Laser-Tissue Interaction, 2134A, pp.309~317 (1994)
- Hossain M, "Effects of Er,Cr:YSGG laser irradiation in human enamel and dentin: ablation and morphological studies", Journal of Clinical Laser Medicine and Surgery, 17, pp.155~ (1999)
- Eversole LR, "Preliminary investigations on the utility of an erbium, chromium:YSGG laser", J Calif Dent Assoc, 23, pp.41~47 (1995)
- Aoki A, "Comparative study of Er:YAG laser and rotating bur for bone ablation: SEM and longterm histological examinations", Lasers in Dentistry, pp.389~391 (2003)
- Wang X, "Morpholgoical changes of bovine mandibular bone irradiated by Er,Cr:YSGG laser: an in vitro study", J Clin Laser Med Surg, 20, pp.245~250 (2002)
- Wang X, "In vivo study of the healing processes that occur in the jaws of rabbits following perforation by an Er,Cr:YSGG laser", Lasers Med Sci, 20, pp.21~27 (2005)
- Riziou I, "Atomized fluid particles for electromagnertically induced cutting. US patent 5,741,247", US patent, ~ (1998)
