The influence of thread geometry on implant osseointegration under immediate loading: a literature review
1
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Implant success is achieved by the synergistic combination of numerous biomechanical factors. This report examines the mechanical aspect of implants. In particular, it is focused on macrodesign such as thread shape, pitch, width and depth, and crestal module of implants. This study reviews the literature regarding the effect of implant thread geometry on primary stability and osseointegration under immediate loading. The search strategy included both in vitro and in vivo studies published in the MEDLINE database from January 2000 to June 2014. Various geometrical parameters are analyzed to evaluate their significance for optimal stress distribution, implant surface area, and bone remodeling responses during the process of osseointegration.
Abstract
Implant success is achieved by the synergistic combination of numerous biomechanical factors. This report examines the mechanical aspect of implants. In particular, it is focused on macrodesign such as thread shape, pitch, width and depth, and crestal module of implants. This study reviews the literature regarding the effect of implant thread geometry on primary stability and osseointegration under immediate loading. The search strategy included both in vitro and in vivo studies published in the MEDLINE database from January 2000 to June 2014. Various geometrical parameters are analyzed to evaluate their significance for optimal stress distribution, implant surface area, and bone remodeling responses during the process of osseointegration.
참고문헌 (50)
- Haas R., "Brånemark single tooth implants : a preliminary report of 76 implants", J Prosthet Dent, 73, pp.274~279 (1995)
- Goodacre CJ., "Clinical complications with implants and implant prostheses", J Prosthet Dent, 90, pp.121~132 (2003)
- Fugazzotto PA., "Success and failure rates of osseointegrated implants in function in regenerated bone for 72 to 133 months", Int J Oral Maxillofac Implants, 20, pp.77~83 (2005)
- Atieh MA., "Immediate loading with single implant crowns : a systematic review and meta-analysis", Int J Prosthodont, 22, pp.378~387 (2009)
- Cochran DL., "Consensus statements and recommended clinical procedures regarding loading protocols for endosseous dental implants", Int J Oral Maxillofac Implants, 19, pp.109~113 (2004)
- Glauser R., "A systematic review of marginal soft tissue at implants subjected to immediate loading or immediate restoration", Clin Oral Implants Res, 17, pp.82~92 (2006)
- Romanos GE., "Histologic and histomorphometric evaluation of peri-implant bone subjected to immediate loading : an experimental study with Macaca fascicularis", Int J Oral Maxillofac Implants, 17, pp.44~51 (2002)
- Ibañez JC., "Immediate loading of osseotite implants : two-year results", Implant Dent, 11, pp.128~136 (2002)
- Rocci A., "Immediate loading of Brånemark system TiUnite and machined-surface implants in the posterior mandible, part II : a randomized open-ended 9-year follow-up clinical trial", Int J Oral Maxillofac Implants, 28, pp.891~895 (2013)
- Ostman PO., "Direct implant loading in the edentulous maxilla using a bone density-adapted surgical protocol and primary implant stability criteria for inclusion", Clin Implant Dent Relat Res, 7, pp.S60~S69 (2005)
- Sennerby L., "Implant stability measurements using resonance frequency analysis : biological and biomechanical aspects and clinical implications", Periodontol 2000, 47, pp.51~66 (2008)
- Abuhussein H., "The effect of thread pattern upon implant osseointegration", Clin Oral Implants Res, 21, pp.129~136 (2010)
- Boggan RS., "Influence of hex geometry and prosthetic table width on static and fatigue strength of dental implants", J Prosthet Dent, 82, pp.436~440 (1999)
- Hansson S., "The implant thread as a retention element in cortical bone : the effect of thread size and thread profile : a finite element study", J Biomech, 36, pp.1247~1258 (2003)
- Prendergast PJ., "Microdamage and osteocyte-lacuna strain in bone : a microstructural finite element analysis", J Biomech Eng, 118, pp.240~246 (1996)
- Brunski JB., "In vivo bone response to biomechanical loading at the bone", dental-implant interface, 1999, pp.13, 99~119
- Frost HM., "Skeletal structural adaptations to mechanical usage(SATMU) : 1. Redefining Wolff›s law : the bone modeling problem", Anat Rec, 226, pp.403~413 (1990)
- Chang PK., "Distribution of micromotion in implants and alveolar bone with different thread profiles in immediate loading: a finite element study", Int J Oral Maxillofac Implants, 27, pp.e96~e101 (2012)
- Eraslan O., "The effect of thread design on stress distribution in a solid screw implant : a 3D finite element analysis", Clin Oral Investig, 14, pp.411~416 (2010)
- Steigenga J., "Effects of implant thread geometry on percentage of osseointegration and resistance to reverse torque in the tibia of rabbits", J Periodontol, 75, pp.1233~1241 (2004)
- Geng JP., "Finite element analysis of four thread-form configurations in a stepped screw implant", J Oral Rehabil, 31, pp.233~239 (2004)
- Chun HJ., "Evaluation of design parameters of osseointegrated dental implants using finite element analysis", J Oral Rehabil, 29, pp.565~574 (2002)
- McAllister BS., "Two-year evaluation of a variable-thread tapered implant in extraction sites with immediate temporization : a multicenter clinical trial", Int J Oral Maxillofac Implants, 27, pp.611~618 (2012)
- Arnhart C., "Comparison of variable-thread tapered implant designs to a standard tapered implant design after immediate loading. A 3-year multicentre randomised controlled trial", Eur J Oral Implantol, 5, pp.123~136 (2012)
- Ivanoff CJ., "Influence of variations in implant diameters : a 3-to 5-year retrospective clinical report", Int J Oral Maxillofac Implants, 14, pp.173~180 (1999)
- Misch CE., "Short dental implants in posterior partial edentulism : a multicenter retrospective 6-year case series study", J Periodontol, 77, pp.1340~1347 (2006)
- Steigenga JT., "Dental implant design and its relationship to long-term implant success", Implant Dent, 12, pp.306~317 (2003)
- Orsini E., "Dental implant thread pitch and its influence on the osseointegration process : an in vivo comparison study", Int J Oral Maxillofac Implants, 27, pp.383~392 (2012)
- Chung SH., "Effects of implant geometry and sur face treatment on osseointegration after functional loading : a dog study", J Oral Rehabil, 35, pp.229~236 (2008)
- Ma P., "Influence of helix angle and density on primary stability of immediately loaded dental implants : three-dimensional finite element analysis", Zhonghua Kou Qiang Yi Xue Za Zhi, 42, pp.618~621 (2007)
- Motoyoshi M., "Biomechanical effect of abutment on stability of orthodontic mini-implant. A finite element analysis", Clin Oral Implants Res, 16, pp.480~485 (2005)
- Lan TH., "Biomechanical analysis of alveolar bone stress around implants with different thread designs and pitches in the mandibular molar area", Clin Oral Investig, 16, pp.363~369 (2012)
- Kong L., "Optimized thread pitch design and stress analysis of the cylinder screwed dental implant", Hua Xi Kou Qiang Yi Xue Za Zhi, 24, pp.509~515 (2006)
- Misch CE., "Contemporary Implant Dentistry", pp.200~229 (2008), Mosby
- Ao J., "Optimal design of thread height and width on an immediately loaded cylinder implant : a finite element analysis", Comput Biol Med, 40, pp.681~686 (2010)
- Kong L., "Evaluation of the cylinder implant thread height and width : a 3-dimensional finite element analysis", Int J Oral Maxillofac Implants, 23, pp.65~74 (2008)
- Quirynen M., "Fixture design and overload influence marginal bone loss and fixture success in the Brånemark system", Clin Oral Implants Res, 3, pp.104~111 (1992)
- Shimada E., "A pilot study to assess the performance of a partially threaded sintered porous-surfaced dental implant in the dog mandible", Int J Oral Maxillofac Implants, 22, pp.948~954 (2007)
- Hermann JS., "Crestal bone changes around titanium implants : a methodologic study comparing linear radiographic with histometric measurements", Int J Oral Maxillofac Implants, 16, pp.475~485 (2001)
- Hänggi MP., "Crestal bone changes around titanium implants. Part I : A retrospective radiographic evaluation in humans comparing two non-submerged implant designs with different machined collar lengths", J Periodontol, 76, pp.791~802 (2005)
- Vaillancourt H., "Finite element analysis of crestal bone loss around porous-coated dental implants", J Appl Biomater, 6, pp.267~282 (1995)
- Hansson S., "The implant neck : smooth or provided with retention elements. A biomechanical approach", Clin Oral Implants Res, 10, pp.394~405 (1999)
- Chowdhary R, "Influence of micro threads alteration on osseointegration and primary stability of implants: an FEA and in vivo analysis in rabbits", Clin Implant Dent Relat Res (2013)
- Negri B., "Peri-implant tissue reactions to immediate nonocclusal loaded implants with different collar design: an experimental study in dogs", Clin Oral Implants Res, 25, pp.e54~e63 (2014)
- 윤희정, "A short-term clinical study of marginal bone level change around microthreaded and platformswitched implants", Journal of Periodontal & Implant Science, 41(5), pp.211~217 (2011), 대한치주과학회
- Song DW., "Comparative analysis of peri-implant marginal bone loss based on microthread location : a 1-year prospective study after loading", J Periodontol, 80, pp.1937~1944 (2009)
- Lee DW., "Effect of microthread on the maintenance of marginal bone level : a 3-year prospective study", Clin Oral Implants Res, 18, pp.465~470 (2007)
- Calvo-Guirado JL, "Marginal bone loss evaluation around immediate non-occlusal microthreaded implants placed in fresh extraction sockets in the maxilla: a 3-year study", Clin Oral Implants Res (2014)
- Amid R., "Effect of microthread design of dental implants on stress and strain patterns : a three-dimensional finite element analysis", Biomed Tech(Berl), 58, pp.457~467 (2013)
- Schrotenboer J., "Effect of microthreads and platform switching on crestal bone stress levels : a finite element analysis", J Periodontol, 79, pp.2166~2172 (2008)
