Trueness and precision of scanning abutment impressions and stone models according to dental CAD/CAM evaluation standards
2
조회
0
다운로드
3
인용
0
참고문헌
키워드
초록
PURPOSE. The purpose of the present study was to compare scanning trueness and precision between an abutment impression and a stone model according to dental computer-aided design/computer-aided manufacturing (CAD/CAM) evaluation standards. MATERIALS AND METHODS. To evaluate trueness, the abutment impression and stone model were scanned to obtain the first 3-dimensional (3-D) stereolithography (STL) file. Next, the abutment impression or stone model was removed from the scanner and re-fixed on the table; scanning was then repeated so that 11 files were obtained for each scan type. To evaluate precision, the abutment impression or stone model was scanned to obtain the first 3-D STL file. Without moving it, scanning was performed 10 more times, so that 11 files were obtained for each scan type. By superimposing the first scanned STL file onto the other STL files one by one, 10 color-difference maps and reports were obtained; i.e., 10 experimental scans per type. The independent t-test was used to compare root mean square (RMS) data between the groups (α=.05). RESULTS. The RMS±SD values of scanning trueness of the abutment impression and stone model were 22.4±4.4 and 17.4±3.5 μm, respectively (P<.012). The RMS±SD values of scanning precision of the abutment impression and stone model were 16.4±2.9 and 14.6±1.6 μm, respectively (P=.108). CONCLUSION. There was a significant difference in scanning trueness between the abutment impression and stone model, as evaluated according to dental CAD/CAM standards. However, all scans showed high trueness and precision.
Abstract
PURPOSE. The purpose of the present study was to compare scanning trueness and precision between an abutment impression and a stone model according to dental computer-aided design/computer-aided manufacturing (CAD/CAM) evaluation standards. MATERIALS AND METHODS. To evaluate trueness, the abutment impression and stone model were scanned to obtain the first 3-dimensional (3-D) stereolithography (STL) file. Next, the abutment impression or stone model was removed from the scanner and re-fixed on the table; scanning was then repeated so that 11 files were obtained for each scan type. To evaluate precision, the abutment impression or stone model was scanned to obtain the first 3-D STL file. Without moving it, scanning was performed 10 more times, so that 11 files were obtained for each scan type. By superimposing the first scanned STL file onto the other STL files one by one, 10 color-difference maps and reports were obtained; i.e., 10 experimental scans per type. The independent t-test was used to compare root mean square (RMS) data between the groups (α=.05). RESULTS. The RMS±SD values of scanning trueness of the abutment impression and stone model were 22.4±4.4 and 17.4±3.5 μm, respectively (P<.012). The RMS±SD values of scanning precision of the abutment impression and stone model were 16.4±2.9 and 14.6±1.6 μm, respectively (P=.108). CONCLUSION. There was a significant difference in scanning trueness between the abutment impression and stone model, as evaluated according to dental CAD/CAM standards. However, all scans showed high trueness and precision.
참고문헌 (39)
- 정일도, "Ceramic molar crown reproducibility by digital workflow manufacturing: An in vitro study", The Journal of Advanced of Prosthodontics, 9(4), pp.252~256 (2017), 대한치과보철학회[DOI]
- Luthardt RG, "Accuracy of intraoral data acquisition in comparison to the conventional impression", Int J Comput Dent, 8, pp.283~294 (2005)
- Carbajal Mejia JB, "Influence of abutment tooth geometry on the accuracy of conventional and digital methods of obtaining dental impressions", J Prosthet Dent, 118, pp.392~399 (2017)[DOI]
- Gonzalez de Villaumbrosia P, "In vitro comparison of the accuracy (trueness and precision) of six extraoral dental scanners with different scanning technologies", J Prosthet Dent, 116, pp.543~550 (2016)[DOI]
- 전진훈, "Accuracy of 3D white light scanning of abutment teeth impressions: evaluation of trueness and precision", The Journal of Advanced of Prosthodontics, 6(6), pp.468~473 (2014), 대한치과보철학회[DOI]
- Renne W, "Evaluation of the accuracy of 7 digital scanners: An in vitro analysis based on 3-dimensional comparisons", J Prosthet Dent, 118, pp.36~42 (2017)[DOI]
- Lee JJ, "Accuracy of single-abutment digital cast obtained using intraoral and cast scanners", J Prosthet Dent, 117, pp.253~259 (2017)[DOI]
- Bramanti E, "FEM and von Mises analysis on prosthetic crowns structural elements: Evaluation of different applied materials", Sci World J, 2017, pp.1029574~ (2017)
- Cicciu M, "FEM analysis of mandibular prosthetic overdenture supported by dental implants: evaluation of different retention methods", Comput Math Methods Med, 2015, pp.943839~ (2015)
- Cicciu M, "FEM and Von Mises analyses of different dental implant shapes for masticatory loading distribution", Oral Implantol (Rome), 7, pp.1~10 (2014)
- Cicciu M, "FEM evaluation of cemented-retained versus screw-retained dental implant single-tooth crown prosthesis", Int J Clin Exp Med, 7, pp.817~825 (2014)
- "ISO 12836, Dentistry - Digitizing devices for CAD", CAM systems for indirect dental restorations - Test methods for assessing accuracy, 2015
- Jeong ID, "Accuracy of complete-arch model using an intraoral video scanner: An in vitro study", J Prosthet Dent, 115, pp.755~759 (2016)[DOI]
- 전진훈, "White light scanner-based repeatability of 3-dimensional digitizing of silicon rubber abutment teeth impressions", The Journal of Advanced of Prosthodontics, 5(4), pp.452~456 (2013), 대한치과보철학회[DOI]
- 김동연, "Evaluation of marginal and internal gaps in single and three-unit metal frameworks made by micro-stereolithography", The Journal of Advanced of Prosthodontics, 9(4), pp.239~243 (2017), 대한치과보철학회[DOI]
- 이완선, "Evaluation of internal fit of interim crown fabricated with CAD", CAM milling and 3D printing system, 2017, pp.9(4), 265~270[DOI]
- Kournetas N, "Comparative evaluation of topographical data of dental implant surfaces applying optical interferometry and scanning electron microscopy", Dent Mater, 33, pp.e317~e327 (2017)[DOI]
- Nedelcu RG, "Scanning accuracy and precision in 4 intraoral scanners: an in vitro comparison based on 3-dimensional analysis", J Prosthet Dent, 112, pp.1461~1471 (2014)[DOI]
- "ISO-5725-1, Accuracy (trueness and precision) of measurement methods and results. Part 1: General principles and definitions", International Standards for Organization (ISO), ~ (1994)
- Ender A, "Accuracy of complete-arch dental impressions: a new method of measuring trueness and precision", J Prosthet Dent, 109, pp.121~128 (2013)[DOI]
- Lauritano F, "Three-dimensional evaluation of different prosthesis retention systems using finite element analysis and the Von Mises stress test", Minerva Stomatol, 65, pp.353~367 (2016)
- Jeon JH, "Three-dimensional evaluation of the repeatability of scans of stone models and impressions using a blue LED scanner", Dent Mater J, 34, pp.686~691 (2015)[DOI]
- Cicciu M, "Parametric analysis of the strength in the "Toronto" osseous-prosthesis system", Minerva Stomatol, 58, pp.9~23 (2009)
- 전진훈, "Repeatability and reproducibility of individual abutment impression, assessed with a blue light scanner", The Journal of Advanced of Prosthodontics, 8(3), pp.214~218 (2016), 대한치과보철학회[DOI]
- Kim DY, "Reproducibility of different arrangement of resin copings by dental microstereolithography: Evaluating the marginal discrepancy of resin copings", J Prosthet Dent, 117, pp.260~265 (2017)[DOI]
- Ausiello P, "Mechanical behavior of bulk direct composite versus block composite and lithium disilicate indirect Class II restorations by CAD-FEM modeling", Dent Mater, 33, pp.690~701 (2017)[DOI]
- Ausiello P, "The effects of cavity-margin-angles and bolus stiffness on the mechanical behavior of indirect resin composite class II restorations", Dent Mater, 33, pp.e39~e47 (2017)
- Li J, "New approach to establish an object reference frame for dental arch in computer-aided surgical simulation", Int J Oral Maxillofac Surg, 46, pp.1193~1200 (2017)[DOI]
- Lebon N, "Understanding dental CAD", CAM for restorations - dental milling machines from a mechanical engineering viewpoint. Part A: chairside milling machines, 2016, pp.19, 45~62
- Kim CM, "Threedimensional evaluation of the reproducibility of presintered zirconia single copings fabricated with the subtractive method", J Prosthet Dent, 116, pp.237~241 (2016)[DOI]
- Jeon JH, "Three-dimensional evaluation of the repeatability of scanned conventional impressions of prepared teeth generated with white- and blue-light scanners", J Prosthet Dent, 114, pp.549~53 (2015)[DOI]
- Vecsei B, "Comparison of the accuracy of direct and indirect three-dimensional digitizing processes for CAD", CAM systems - An in vitro study, 2017, pp.61, 177~184
- Moser M, "Patientspecific polymethylmethacrylate prostheses for secondary re- construction of large calvarial defects: A retrospective feasibility study of a new intraoperative moulding device for cranioplasty", J Craniomaxillofac Surg, 45, pp.295~303 (2017)[DOI]
- Kim DS, "Comparison of dynamics in 3D glenohumeral position between primary dislocated shoulders and contralateral healthy shoulders", J Orthop, 14, pp.195~200 (2017)[DOI]
- Liu L, "Calcium channel opening rather than the release of ATP causes the apoptosis of osteoblasts induced by overloaded mechanical stimulation", Cell Physiol Biochem, 42, pp.441~454 (2017)[DOI]
- Martorelli M, "A new method to assess the accuracy of a Cone Beam Computed Tomography scanner by using a non-contact reverse engineering technique", J Dent, 42, pp.460~465 (2014)[DOI]
- Flugge TV, "Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner", Am J Orthod Dentofacial Orthop, 144, pp.471~478 (2013)[DOI]
- Persson AS, "Computer aided analysis of digitized dental stone replicas by dental CAD", CAM technology, 2008, pp.24, 1123~1130
- Quaas S, "Direct mechanical data acquisition of dental impressions for the manufacturing of CAD", CAM restorations, 2007, pp.35, 903~908