본문 바로가기
KERD
논문KCI 등재

Comparison of marginal bone loss and patient satisfaction in single and double-implant assisted mandibular overdenture by immediate loading

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

PURPOSE. The purpose of this study was to compare the coronal bone level and patient satisfaction in 1-implant and 2-implant assisted mandibular overdentures. MATERIALS AND METHODS. Twenty patients who had maladaptive mandibular dentures were treated in this study. Patients were randomly divided into two groups. The first group received 1 implant (Simple line II, Implantium, South Korea) in their mandibular midline and the second group received 2 implants in their B and D regions (according to Misch’s category). If the primary stability of each implant was at least 60 ISQ, ball attachment was placed and denture relined with soft liner. After 6 weeks, retentive cap incorporated with hard acrylic resin. In the 6 and 12 months recalls, periapical digital radiograph were made and visual analogue scale questionnaires were used to record patient satisfaction. The Friedman test was done for comparing the presurgical and postsurgical parameters in each group and the U-Mann Whitney test (P<.05) was done for comparison of post-treatment results between the two groups. RESULTS. All implants achieved sufficient primary stability to be immediately loaded. Patient satisfaction was high, and there were no significant differences between two groups (P>.05). In addition, mean marginal bone loss was 0.6 ± 0.67 mm in the first group and 0.6 ± 0.51 mm in the second group, after 12 month. Mean marginal bone loss showed no significant differences between two groups. CONCLUSION. This preliminary oneyear result indicated that mandibular overdentures anchored to a single implant can be a safe and cost-effective method as a starting step for implant-overdenture treatment.

Abstract

PURPOSE. The purpose of this study was to compare the coronal bone level and patient satisfaction in 1-implant and 2-implant assisted mandibular overdentures. MATERIALS AND METHODS. Twenty patients who had maladaptive mandibular dentures were treated in this study. Patients were randomly divided into two groups. The first group received 1 implant (Simple line II, Implantium, South Korea) in their mandibular midline and the second group received 2 implants in their B and D regions (according to Misch’s category). If the primary stability of each implant was at least 60 ISQ, ball attachment was placed and denture relined with soft liner. After 6 weeks, retentive cap incorporated with hard acrylic resin. In the 6 and 12 months recalls, periapical digital radiograph were made and visual analogue scale questionnaires were used to record patient satisfaction. The Friedman test was done for comparing the presurgical and postsurgical parameters in each group and the U-Mann Whitney test (P<.05) was done for comparison of post-treatment results between the two groups. RESULTS. All implants achieved sufficient primary stability to be immediately loaded. Patient satisfaction was high, and there were no significant differences between two groups (P>.05). In addition, mean marginal bone loss was 0.6 ± 0.67 mm in the first group and 0.6 ± 0.51 mm in the second group, after 12 month. Mean marginal bone loss showed no significant differences between two groups. CONCLUSION. This preliminary oneyear result indicated that mandibular overdentures anchored to a single implant can be a safe and cost-effective method as a starting step for implant-overdenture treatment.

참고문헌 (34)

  1. Redford M, "Denture use and the technical quality of dental prostheses among persons 18-74 years of age: United States, 1988-1991", J Dent Res, 75, pp.714~725 (1996)
  2. Dias R, "Patient satisfaction survey of mandibular two-implant-retained overdentures in a predoctoral program", J Prosthet Dent, 110, pp.76~81 (2013)
  3. Preciado A, "Differences in impact of patient and prosthetic characteristics on oral health-related quality of life among implant-retained overdenture wearers", J Dent, 40, pp.857~865 (2012)
  4. Cochran DL, "The evidence for immediate loading of implants", J Evid Based Dent Pract, 6, pp.155~163 (2006)
  5. Stephan G, "Implant-retained mandibular overdentures: a comparative pilot study of immediate loading versus delayed loading after two years", J Prosthet Dent, 97, pp.S138~S145 (2007)
  6. Kacer CM, "Immediate loading of dental implants in the anterior and posterior mandible: a retrospective study of 120 cases", J Oral Maxillofac Surg, 68, pp.2861~2867 (2010)
  7. Attard NJ, "Immediate and early implant loading protocols: a literature review of clinical studies", J Prosthet Dent, 94, pp.242~258 (2005)
  8. Burns DR, "Randomized, prospective, clinical evaluation of prosthodontic modalities for mandibular implant overdenture treatment", J Prosthet Dent, 106, pp.12~22 (2011)
  9. Visser A, "Mandibular overdentures supported by two or four endosseous implants. A 5-year prospective study", Clin Oral Implants Res, 16, pp.19~25 (2005)
  10. Batenburg RH, "Mandibular overdentures supported by two or four endosteal implants. A prospective, comparative study", Int J Oral Maxillofac Surg, 27, pp.435~439 (1998)
  11. Payne AG, "Oneyear prospective evaluation of the early loading of unsplinted conical Brånemark fixtures with mandibular overdentures immediately following surgery", Clin Implant Dent Relat Res, 3, pp.9~19 (2001)
  12. Daas M, "A complete finite element model of a mandibular implant-retained overdenture with two implants: comparison between rigid and resilient attachment configurations", Med Eng Phys, 30, pp.218~225 (2008)
  13. Feine JS, "The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients", Int J Oral Maxillofac Implants, 17, pp.601~602 (2002)
  14. Liddelow GJ, "A prospective study of immediately loaded single implant-retained mandibular overdentures: preliminary one-year results", J Prosthet Dent, 97, pp.S126~S137 (2007)
  15. Cheng T, "Patient satisfaction and masticatory efficiency of single implant-retained mandibular overdentures using the stud and magnetic attachments", J Dent, 40, pp.1018~1023 (2012)
  16. Cordioli G, "Mandibular overdentures anchored to single implants: a five-year prospective study", J Prosthet Dent, 78, pp.159~165 (1997)
  17. Liu J, "Influence of implant number on the biomechanical behaviour of mandibular implant-retained", supported overdentures: a three-dimensional finite element analysis, 2013, pp.41, 241~249
  18. Passia N, "Six-year clinical outcome of single implant-retained mandibular overdentures - a pilot study", Clin Oral Implants Res (2014)
  19. Jokstad A, "What is the effect on outcomes of timeto-loading of a fixed or removable prosthesis placed on implant(s)?", Int J Oral Maxillofac Implants, 22, pp.19~48 (2007)
  20. California Dental Association, "Quality evaluation for dental care: guidelines for the assessment of clinical quality and professional performance", pp.61~64 (1977), California Dental Association
  21. Misch CE, "Contemporary of implant dentistry", pp.299~310 (2008), CV Mosby
  22. de Grandmont P, "Within-subject comparisons of implant-supported mandibular prostheses: psychometric evaluation", J Dent Res, 73, pp.1096~1104 (1994)
  23. Dent CD, "The influence of preoperative antibiotics on success of endosseous implants up to and including stage II surgery:a study of 2,641 implants", J Oral Maxillofac Surg, 55, pp.19~24 (1997)
  24. Susarla SM, "Delayed versus immediate loading of implants: survival analysis and risk factors for dental implant failure", J Oral Maxillofac Surg, 66, pp.251~255 (2008)
  25. Stricker A, "Immediate loading of 2 interforaminal dental implants supporting an overdenture: clinical and radiographic results after 24months", Int J Oral Maxillofac Implants, 19, pp.868~872 (2004)
  26. Komiyama A, "Treatment outcome of immediately loaded implants installed in edentulous jaws following computer-assisted virtual treatment planning and flapless surgery", Clin Oral Implants Res, 19, pp.677~685 (2008)
  27. Szmukler-Moncler S, "Considerations preliminary to the application of early and immediate loading protocols in dental implantology", Clin Oral Implants Res, 11, pp.12~25 (2000)
  28. Naert I, "A 5-year prospective randomized clinical trial on the influence of splinted and unsplinted oral implants retaining a mandibular overdenture:prosthetic aspects and patient satisfaction", J Oral Rehabil, 26, pp.195~202 (1999)
  29. Tokuhisa M, "In vitro study of a mandibular implant overdenture retained with ball, magnet, or bar attachments: comparison of load transfer and denture stability", Int J Prosthodont, 16, pp.128~134 (2003)
  30. Taylor TD, "Implant overdentures as the standard of care for edentulous patients", pp.71~81 (2003), Quintessence
  31. Fueki K, "Effect of implant-supported or retained dentures on masticatory performance:a systematic review", J Prosthet Dent, 98, pp.470~477 (2007)
  32. Geertman ME, "Two-center clinical trial of implant-retained mandibular overdentures versus complete dentures-chewing ability", Community Dent Oral Epidemiol, 24, pp.79~84 (1996)
  33. Kronstrom M, "Immediate functional loading of 1or 2 dental implants supporting a ball retained mandibular overdenture: Interim results of a randomized prospective study", J Oral Maxillofac Surg, 68, pp.e15~ (2010)
  34. Roos J, "A qualitative and quantitative method for evaluating implant success: a 5-year retrospective analysis of the Brånemark implant", Int J Oral Maxillofac Implants, 12, pp.504~514 (1997)

관련 논문AI추천

Implant and root supported overdentures - a literature review and some data on bone loss in edentulous jawsGunnar E Carlsson대한치과보철학회 · The Journal of Advanced of Prosthodontics2014 · 제6권 제4호Clinical evaluation of mandibular implant overdentures via Locator implant attachment and Locator bar attachment김정우, 배은빈, 서용호, 윤미정, 이소현, 전영찬, 정창모, 허중보대한치과보철학회 · The Journal of Advanced of Prosthodontics2016 · 제8권 제4호Number of implants for mandibular implant overdentures: a systematic review김하영, 신상완, 이정열, S. Ross Bryant대한치과보철학회 · The Journal of Advanced of Prosthodontics2012 · 제4권 제4호Standardizing the evaluation criteria on treatment outcomes of mandibular implant overdentures: a systematic review김하영, 신상완, 이정열대한치과보철학회 · The Journal of Advanced of Prosthodontics2014 · 제6권 제5호Influence of marginal bone resorption on two mini implant-retained mandibular overdenture: An in vitro studyChikahiro Ohkubo, Jian-Yu Zeng, Jing Zhang, Kentaro Kono, Yasunori Suzuki, Ying Guo대한치과보철학회 · The Journal of Advanced of Prosthodontics2021 · 제13권 제1호Effect of implant diameter and cantilever length on the marginal bone height changes and stability of implants supporting screw retained prostheses: A randomized double blinded control trialAmr Mohamed Ekram, Heba Ezzeldin Khorshid, Noha Ossama Issa대한치과보철학회 · The Journal of Advanced of Prosthodontics2023 · 제15권 제3호

이 간행물의 다른 논문 (10건)