본문 바로가기
KERD
논문KCI 등재

Comparative analysis on reproducibility among 5 intraoral scanners: sectional analysis according to restoration type and preparation outline form

2

조회

0

다운로드

10

인용

0

참고문헌

키워드

초록

PURPOSE. The trueness and precision of acquired images of intraoral digital scanners could be influenced by restoration type, preparation outline form, scanning technology and the application of power. The aim of this study is to perform the comparative evaluation of the 3-dimensional reproducibility of intraoral scanners (IOSs). MATERIALS AND METHODS. The phantom containing five prepared teeth was scanned by the reference scanner (Dental Wings) and 5 test IOSs (E4D dentist, Fastscan, iTero, Trios and Zfx Intrascan). The acquired images of the scanner groups were compared with the image from the reference scanner (trueness) and within each scanner groups (precision). Statistical analysis was performed using independent two-samples t-test and analysis of variance (α=.05). RESULTS. The average deviations of trueness and precision of Fastscan, iTero and Trios were significantly lower than the other scanners. According to the restoration type, significantly higher trueness was observed in crown and inlay than in bridge. However, no significant difference was observed among four sites of preparation outline form. If compared by the characteristics of IOS, high trueness was observed in the group adopting the active triangulation and using powder. However, there was no significant difference between the still image acquisition and video acquisition groups. CONCLUSION. Except for two intraoral scanners, Fastscan, iTero and Trios displayed comparable levels of trueness and precision values in tested phantom model. Difference in trueness was observed depending on the restoration type, the preparation outline form and characteristics of IOS, which should be taken into consideration when the intraoral scanning data are utilized.

Abstract

PURPOSE. The trueness and precision of acquired images of intraoral digital scanners could be influenced by restoration type, preparation outline form, scanning technology and the application of power. The aim of this study is to perform the comparative evaluation of the 3-dimensional reproducibility of intraoral scanners (IOSs). MATERIALS AND METHODS. The phantom containing five prepared teeth was scanned by the reference scanner (Dental Wings) and 5 test IOSs (E4D dentist, Fastscan, iTero, Trios and Zfx Intrascan). The acquired images of the scanner groups were compared with the image from the reference scanner (trueness) and within each scanner groups (precision). Statistical analysis was performed using independent two-samples t-test and analysis of variance (α=.05). RESULTS. The average deviations of trueness and precision of Fastscan, iTero and Trios were significantly lower than the other scanners. According to the restoration type, significantly higher trueness was observed in crown and inlay than in bridge. However, no significant difference was observed among four sites of preparation outline form. If compared by the characteristics of IOS, high trueness was observed in the group adopting the active triangulation and using powder. However, there was no significant difference between the still image acquisition and video acquisition groups. CONCLUSION. Except for two intraoral scanners, Fastscan, iTero and Trios displayed comparable levels of trueness and precision values in tested phantom model. Difference in trueness was observed depending on the restoration type, the preparation outline form and characteristics of IOS, which should be taken into consideration when the intraoral scanning data are utilized.

참고문헌 (27)

  1. Miyazaki T, "A review of dental CAD", CAM: current status and future perspectives from 20 years of experience, 2009, pp.28, 44~56
  2. Nedelcu RG, "Scanning accuracy and precision in 4 intraoral scanners: an in vitro comparison based on 3-dimensional analysis", J Prosthet Dent, 112, pp.1461~1471 (2014)
  3. Schaefer O, "Impact of digital impression techniques on the adaption of ceramic partial crowns in vitro", J Dent, 42, pp.677~683 (2014)
  4. Logozzo S, "Recent advances in dental optics – Part I: 3D intraoral scanners for restorative dentistry", Opt Laser Eng, 54, pp.203~221 (2014)
  5. Seelbach P, "Accuracy of digital and conventional impression techniques and workflow", Clin Oral Investig, 17, pp.1759~1764 (2013)
  6. Ender A, "Full arch scans: conventional versus digital impressions-an in-vitro study", Int J Comput Dent, 14, pp.11~21 (2011)
  7. Ender A, "Influence of scanning strategies on the accuracy of digital intraoral scanning systems", Int J Comput Dent, 16, pp.11~21 (2013)
  8. Ender A, "In-vitro evaluation of the accuracy of conventional and digital methods of obtaining full-arch dental impressions", Quintessence Int, 46, pp.9~17 (2015)
  9. Patzelt SB, "Assessing the feasibility and accuracy of digitizing edentulous jaws", J Am Dent Assoc, 144, pp.914~920 (2013)
  10. Patzelt SB, "Accuracy of full-arch scans using intraoral scanners", Clin Oral Investig, 18, pp.1687~1694 (2014)
  11. Papaspyridakos P, "Digital versus conventional implant impressions for edentulous patients: accuracy outcomes", Clin Oral Implants Res, 27, pp.465~472 (2016)
  12. Andriessen FS, "Applicability and accuracy of an intraoral scanner for scanning multiple implants in edentulous mandibles: a pilot study", J Prosthet Dent, 111, pp.186~194 (2014)
  13. van der Meer WJ, "Application of intra-oral dental scanners in the digital workflow of implantology", PLoS One, 7, pp.e43312~ (2012)
  14. Kim SR, "Digitization of dental alginate impression: Three-dimensional evaluation of point cloud", Dent Mater J, 34, pp.835~840 (2015)
  15. Atzeni E, "Proposal of an innovative benchmark for accuracy evaluation of dental crown manufacturing", Comput Biol Med, 42, pp.548~555 (2012)
  16. Paranhos LR, "Correlation between maxillary central incisor crown morphology and mandibular dental arch form in normal occlusion subjects", Braz Dent J, 23, pp.149~153 (2012)
  17. Paranhos LR, "Association between the facial type and morphol-ogy of the upper central incisor in normal occlusion subjects", J Contemp Dent Pract, 15, pp.29~33 (2014)
  18. Martin CB, "Orthodontic scanners: what’s available?", J Orthod, 42, pp.136~143 (2015)
  19. Sannino G, "Dental Wings CAD", CAM system precision: an internal and marginal fit sperimental analisys, 2009, pp.2, 11~20
  20. Mehl A, "Accuracy testing of a new intraoral 3D camera", Int J Comput Dent, 12, pp.11~28 (2009)
  21. Kim SY, "Accuracy of dies captured by an intraoral digital impression system using parallel confocal imaging", Int J Prosthodont, 26, pp.161~163 (2013)
  22. Ender A, "Accuracy of complete-arch dental impressions:a new method of measuring trueness and precision", J Prosthet Dent, 109, pp.121~128 (2013)
  23. An S, "Evaluating the marginal fit of zirconia copings with digital impressions with an intraoral digital scanner", J Prosthet Dent, 112, pp.1171~1175 (2014)
  24. Keul C, "Fit of 4-unit FDPs made of zirconia and CoCr-alloy after chairside and labside digitalization-a laboratory study", Dent Mater, 30, pp.400~407 (2014)
  25. Brawek PK, "The clinical accuracy of single crowns exclusively fabricated by digital workflow-the comparison of two systems", Clin Oral Investig, 17, pp.2119~2125 (2013)
  26. Sturdevant JR, "Margin gap size of ceramic inlays using second-generation CAD", CAM equipment, 1999, pp.11, 206~214
  27. Rupf S, "Exposure of patient and dental staff to fine and ultrafine particles from scanning spray", Clin Oral Investig, 19, pp.823~830 (2015)

관련 논문AI추천

이 간행물의 다른 논문 (10건)