본문 바로가기
KERD
논문KCI 등재

Comparative clinical study of the marginal discrepancy of fixed dental prosthesis fabricated by the millingsintering method using a presintered alloy

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

PURPOSE. The present study was designed to examine the clinical fit of fixed dental prosthesis fabricated by the milling-sintering method using a presintered cobalt-chromium alloy. MATERIALS AND METHODS. Two single metal-ceramic crowns were fabricated via milling-sintering method and casting method in each of the twelve consecutive patients who required an implant-supported fixed prosthesis. In the milling-sintering method, the prosthetic coping was designed in computer software, and the design was converted to a non-precious alloy coping using milling and post-sintering process. In the casting method, the conventional manual fabrication process was applied. The absolute marginal discrepancy of the prostheses was evaluated intraorally using the triple-scan technique. Statistical analysis was conducted using Mann-Whitney U test (α=.05). RESULTS. Eight patients (66.7%) showed a lower marginal discrepancy of the prostheses made using the milling-sintering method than that of the prosthesis made by the casting method. Statistically, the misfit of the prosthesis fabricated using the milling-sintering method was not significantly different from that fabricated using the casting method (P=.782). There was no tendency between the amount of marginal discrepancy and the measurement point. CONCLUSION. The overall marginal fit of prosthesis fabricated by milling-sintering using a presintered alloy was comparable to that of the prosthesis fabricated by the conventional casting method in clinical use.

Abstract

PURPOSE. The present study was designed to examine the clinical fit of fixed dental prosthesis fabricated by the milling-sintering method using a presintered cobalt-chromium alloy. MATERIALS AND METHODS. Two single metal-ceramic crowns were fabricated via milling-sintering method and casting method in each of the twelve consecutive patients who required an implant-supported fixed prosthesis. In the milling-sintering method, the prosthetic coping was designed in computer software, and the design was converted to a non-precious alloy coping using milling and post-sintering process. In the casting method, the conventional manual fabrication process was applied. The absolute marginal discrepancy of the prostheses was evaluated intraorally using the triple-scan technique. Statistical analysis was conducted using Mann-Whitney U test (α=.05). RESULTS. Eight patients (66.7%) showed a lower marginal discrepancy of the prostheses made using the milling-sintering method than that of the prosthesis made by the casting method. Statistically, the misfit of the prosthesis fabricated using the milling-sintering method was not significantly different from that fabricated using the casting method (P=.782). There was no tendency between the amount of marginal discrepancy and the measurement point. CONCLUSION. The overall marginal fit of prosthesis fabricated by milling-sintering using a presintered alloy was comparable to that of the prosthesis fabricated by the conventional casting method in clinical use.

참고문헌 (26)

  1. Wataha JC, "Casting alloys", Dent Clin North Am, 48, pp.vii~viii (2004)
  2. Roberts HW, "Metalceramic alloys in dentistry : a review", J Prosthodont, 18, pp.188~194 (2009)
  3. Ziebert GJ, "Accuracy of one-piece castings, preceramic and postceramic soldering", J Prosthet Dent, 55, pp.312~317 (1986)
  4. Mai HN, "Comparative study of the fit accuracy of full-arch bar frameworks fabricated with different presintered cobalt-chromium alloys", Biomed Res Int, 2018, pp.1962514~ (2018)
  5. Hedberg YS, "In vitro biocompatibility of CoCrMo dental alloys fabricated by selective laser melting", Dent Mater, 30, pp.525~534 (2014)
  6. Ucar Y, "Mechanical properties, fracture surface characterization, and microstructural analysis of six noble dental casting alloys", J Prosthet Dent, 105, pp.394~402 (2011)
  7. Beuer F, "Digital dentistry : an overview of recent developments for CAD", CAM generated restorations, 2008, pp.204, 505~511
  8. Joda T, "Digital vs. conventional implant prosthetic workflows: a cost", time analysis, 2015, pp.26, 1430~1435
  9. Krug KP, "Fracture behavior of metal-ceramic fixed dental prostheses with frameworks from cast or a newly developed sintered cobalt-chromium alloy", Clin Oral Investig, 19, pp.401~411 (2015)
  10. Ortorp A, "Comparisons of precision of fit between cast and CNC-milled titanium implant frameworks for the edentulous mandible", Int J Prosthodont, 16, pp.194~200 (2003)
  11. Hyun-Wook Woo, "Precision of the milled full-arch framework fabricated using presintered soft alloy: A pilot study", The Journal of Advanced of Prosthodontics, 10(2), pp.128~131 (2018), 대한치과보철학회[DOI]
  12. Paniz G, "The precision of fit of cast and milled full-arch implant-supported restorations", Int J Oral Maxillofac Implants, 28, pp.687~693 (2013)
  13. 홍준태, "A comparative study on the bond strength of porcelain to the millingable Pd-Ag alloy", The Journal of Advanced of Prosthodontics, 6(5), pp.372~378 (2014), 대한치과보철학회[DOI]
  14. Stawarczyk B, "A novel CAD", CAM base metal compared to conventional CoCrMo alloys : an in-vitro study of the long-term metal-ceramic bond strength, 2014, pp.13, 446~452
  15. Park JK, "Evaluation of the fit of metal ceramic restorations fabricated with a pre-sintered soft alloy", J Prosthet Dent, 116, pp.909~915 (2016)
  16. Holmes JR, "Considerations in measurement of marginal fit", J Prosthet Dent, 62, pp.405~408 (1989)
  17. Boitelle P, "A systematic review of CAD", CAM fit restoration evaluations, 2014, pp.41, 853~874
  18. Rossetti PH, "Correlation between margin fit and microleakage in complete crowns cemented with three luting agents", J Appl Oral Sci, 16, pp.64~69 (2008)
  19. Trajtenberg CP1, "Microleakage of all-ceramic crowns using self-etching resin luting agents", Oper Dent, 33, pp.392~399 (2008)
  20. Mai HN, "Effects of image and education on the precision of the measurement method for evaluating prosthesis misfit", J Prosthet Dent, 119, pp.600~605 (2018)
  21. Kocaağaoğlu H, "In vitro evaluation of marginal, axial, and occlusal discrepancies in metal ceramic restorations produced with new technologies", J Prosthet Dent, 116, pp.368~374 (2016)
  22. Pasali B, "Evaluation of marginal fit of single implant-supported metal-ceramic crowns prepared by using presintered metal blocks", J Prosthet Dent, 119, pp.257~262 (2018)
  23. Kim HR, "Comparison of in vitro biocompatibility of a Co-Cr dental alloy produced by new milling", post-sintering or traditional casting technique, 2016, pp.178, 300~303
  24. Kim HR, "Microstructures and mechanical properties of Co-Cr dental alloys fabricated by three CAD", CAM-based processing techniques, 2016, pp.9, 596~609
  25. 김동연, "Evaluation of marginal and internal gap of three-unit metal framework according to subtractive manufacturing and additive manufacturing of CAD", CAM systems, 2017, pp.9(6), 463~469[DOI]
  26. Jang SH, "Effect of different post-sintering temperatures on the microstructures and mechanical properties of a pre-sintered Co-Cr alloy", Metals, 8, pp.1036~1044 (2018)

관련 논문AI추천

Precision of the milled full-arch framework fabricated using presintered soft alloy: A pilot study이규복, 이두형, 이청희, 조성암, 조진현, Hyun-Wook Woo대한치과보철학회 · The Journal of Advanced of Prosthodontics2018 · 제10권 제2호Evaluation of marginal discrepancy in metal frameworks fabricated by sintering-based computer-aided manufacturing methodsÇağri Ural, Necati Kaleli, Yeşim Ölçer Us대한치과보철학회 · The Journal of Advanced of Prosthodontics2020 · 제12권 제3호Fitting accuracy of ceramic veneered Co-Cr crowns produced by different manufacturing processesFlorian Bernhard, Nadine Freifrau von Maltzahn, Philipp Kohorst대한치과보철학회 · The Journal of Advanced of Prosthodontics2020 · 제12권 제2호Accuracy evaluation of metal copings fabricated by computer-aided milling and direct metal laser sintering systems김웅철, 김지환, 김혜영, 박종경, 이완선대한치과보철학회 · The Journal of Advanced of Prosthodontics2015 · 제7권 제2호Role of span length in the adaptation of implant-supported cobalt chromium frameworks fabricated by three techniquesHuang Yiqing, Li Yong, Ma Xiao, Wang Jiawei, Zhou Ying대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제2호Evaluation of the marginal and internal gap of metal-ceramic crown fabricated with a selective laser sintering technology: two- and threedimensional replica techniques김기백, 김웅철, 김재홍, 김지환, 김혜영대한치과보철학회 · The Journal of Advanced of Prosthodontics2013 · 제5권 제2호

이 간행물의 다른 논문 (7건)