Accuracy of different electronic torque drivers: A comparative evaluation

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

PURPOSE. This study aims to evaluate the loosening torque on the implant fixture, and to assess the accuracy of difference electronic torque drivers. MATERIALS AND METHODS. Three electronic torque drivers were used to measure the loosening torque on the implant system (AnyOne; MegaGen). The implant fixtures were divided among the 3 electronic torque driver types (W&H, SAESHIN, and NSK group) and 9 for each group. The screws were fastened at the implant fixture by three electronic torque drivers using the tightening torques recommended by the manufacturers of the drivers. After 10 minutes, the screws were again fastened at the implant fixture with equal torque. Then, the loosening torques were measured with an MGT12 torque gauge (MARK-10, Inc.). This measurement procedure was repeated 10 times under loosening torques of 15 Ncm, 25 Ncm, and 35 Ncm. In the statistical analysis, all values of loosening torque were analyzed with the one-way ANOVA and Kruskal-Wallis test (α=.05) for comparative evaluation. RESULTS. There were significant inter-group differences at loosening torques of 15 Ncm and 25 Ncm (P<.05). The accuracy of the NSK driver was the highest, followed by SAESHIN and W&H. There was no significant difference between NSK and W&H at 35 Ncm (P>.05). The SAESHIN driver showed the closest loosening torque at 35 Ncm. CONCLUSION. The most accurate loosening torques were SAESHIN at 35 Ncm, and NSK at 15 Ncm and 25 Ncm. Since the loosening torque may vary depending on the tightening torques and electronic torque drivers, periodic calibration of the electronic torque driver is recommended.

Abstract

PURPOSE. This study aims to evaluate the loosening torque on the implant fixture, and to assess the accuracy of difference electronic torque drivers. MATERIALS AND METHODS. Three electronic torque drivers were used to measure the loosening torque on the implant system (AnyOne; MegaGen). The implant fixtures were divided among the 3 electronic torque driver types (W&H, SAESHIN, and NSK group) and 9 for each group. The screws were fastened at the implant fixture by three electronic torque drivers using the tightening torques recommended by the manufacturers of the drivers. After 10 minutes, the screws were again fastened at the implant fixture with equal torque. Then, the loosening torques were measured with an MGT12 torque gauge (MARK-10, Inc.). This measurement procedure was repeated 10 times under loosening torques of 15 Ncm, 25 Ncm, and 35 Ncm. In the statistical analysis, all values of loosening torque were analyzed with the one-way ANOVA and Kruskal-Wallis test (α=.05) for comparative evaluation. RESULTS. There were significant inter-group differences at loosening torques of 15 Ncm and 25 Ncm (P<.05). The accuracy of the NSK driver was the highest, followed by SAESHIN and W&H. There was no significant difference between NSK and W&H at 35 Ncm (P>.05). The SAESHIN driver showed the closest loosening torque at 35 Ncm. CONCLUSION. The most accurate loosening torques were SAESHIN at 35 Ncm, and NSK at 15 Ncm and 25 Ncm. Since the loosening torque may vary depending on the tightening torques and electronic torque drivers, periodic calibration of the electronic torque driver is recommended.

참고문헌 (60)

  1. Brånemark PI, "Osseointegration and its experimental background", J Prosthet Dent, 50, pp.399~410 (1983)
  2. Sumi T, "Characteristics of implant-CAD", CAM abutment connections of two different internal connection systems, 2012, pp.39, 391~398
  3. Lang LA, "Evaluation of the precision of fit between the Procera custom abutment and various implant systems", Int J Oral Maxillofac Implants, 18, pp.652~658 (2003)
  4. Adell R, "Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws", Int J Oral Maxillofac Implants, 5, pp.347~359 (1990)
  5. Binon PP, "The effect of implant", abutment hexagonal misfit on screw joint stability, 1996, pp.9, 149~160
  6. Lee WJ, "Stress of dental implant abutment screw by the tightening torque", J Korean Acad Prosthodont, 36, pp.721~737 (1998)
  7. Lim JB, "The effect of screw hole sealing method on abutment screw loosening in dental implant", J Korean Acad Prosthodont, 35, pp.767~780 (1997)
  8. Cho SM, "A study on geometric comparison of four interchangeable implant prosthetic retaining screws and measurement of loosening torgue", J Korean Acad Prosthodont, 36, pp.468~482 (1998)
  9. Balshi TJ, "A comparative study of one implant versus two replacing a single molar", Int J Oral Maxillofac Implants, 11, pp.372~378 (1996)
  10. Kemppainen P, "A comparative prospective clinical study of two single-tooth implants : a preliminary report of 102 implants", J Prosthet Dent, 77, pp.382~387 (1997)
  11. Cho IH, "Biomechanical analysis of implant prosthodontic restorations", J Korean Dent Assoc, 31, pp.438~443 (1993)
  12. Binon PP, "The effect of implant", abutment hexagonal misfit on screw joint stability, 1996, pp.9, 149~160
  13. Binon PP, "Implants and components : entering the new millennium", Int J Oral Maxillofac Implants, 15, pp.76~94 (2000)
  14. Misch CE, "Contemporary implant dentistry", pp.669~685 (1999), CV Mosby
  15. Ivanoff CJ, "Reintegration of mobilized titanium implants. An experimental study in rabbit tibia", Int J Oral Maxillofac Surg, 26, pp.310~315 (1997)
  16. 고석민, "골밀도 평가방법과 임플란트 안정성 변화의 관찰", Journal of Periodontal & Implant Science, 39(2), pp.185~192 (2009), 대한치주과학회
  17. Park YS, "Correlation between microtomography and histomorphometry for assessment of implant osseointegration", Clin Oral Implants Res, 16, pp.156~160 (2005)
  18. Sennerby L, "Bone tissue responses to surface-modified zirconia implants : A histomorphometric and removal torque study in the rabbit", Clin Implant Dent Relat Res, 7, pp.S13~20 (2005)
  19. Klokkevold PR, "Early endosseous integration enhanced by dual acid etching of titanium : a torque removal study in the rabbit", Clin Oral Implants Res, 12, pp.350~357 (2001)
  20. Westover L, "Comparison of implant stability measurement devices for bone-anchored hearing aid systems", J Prosthet Dent, 119, pp.178~184 (2018)
  21. Friberg B, "Stability measurements of one-stage Brånemark implants during healing in mandibles. A clinical resonance frequency analysis study", Int J Oral Maxillofac Surg, 28, pp.266~272 (1999)
  22. Meredith N, "The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia", Clin Oral Implants Res, 8, pp.234~243 (1997)
  23. Sennerby L, "A new microtomographic technique for non-invasive evaluation of the bone structure around implants", Clin Oral Implants Res, 12, pp.91~94 (2001)
  24. Fanuscu MI, "Three-dimensional morphometric analysis of human cadaver bone : microstructural data from maxilla and mandible", Clin Oral Implants Res, 15, pp.213~218 (2004)
  25. Brandt J, "Extended push-out test to characterize the failure of boneimplant interface", Biomed Tech(Berl), 50, pp.201~206 (2005)
  26. Dhert WJ, "A finite element analysis of the pushout test : influence of test conditions", J Biomed Mater Res, 26, pp.119~130 (1992)
  27. Cibirka RM, "Examination of the implant-abutment interface after fatigue testing", J Prosthet Dent, 85, pp.268~275 (2001)
  28. Elshahawy W, "Failure torque of ceramic neck titanium implant", J Prosthet Dent, 119, pp.432~436 (2018)
  29. Faulkner MG, "Measuring abutment", implant joint integrity with the Periotest instrument, 1999, pp.14, 681~688
  30. Haack JE, "Elongation and preload stress in dental implant abutment screws", Int J Oral Maxillofac Implants, 10, pp.529~536 (1995)
  31. Martin WC, "Implant abutment screw rotations and preloads for four different screw materials and surfaces", J Prosthet Dent, 86, pp.24~32 (2001)
  32. Gross M, "Microleakage at the abutment-implant interface of osseointegrated implants : a comparative study", Int J Oral Maxillofac Implants, 14, pp.94~100 (1999)
  33. 김대곤, "임플란트 토크 조절기의 비교 분석 연구", 구강회복응용과학지, 28(1), pp.27~36 (2012), 대한턱관절교합학회
  34. Jaarda MJ, "Providing optimum torque to implant prostheses : a pilot study", Implant Dent, 2, pp.50~52 (1993)
  35. Goheen KL, "Torque generated by handheld screwdrivers and mechanical torquing devices for osseointegrated implants", Int J Oral Maxillofac Implants, 9, pp.149~155 (1994)
  36. Tan KB, "The effect of 3 torque delivery systems on gold screw preload at the gold cylinder-abutment screw joint", Int J Oral Maxillofac Implants, 17, pp.175~183 (2002)
  37. Vallee MC, "Accuracy of fric-tion-style and spring-style mechanical torque limiting devices for dental implants", J Prosthet Dent, 100, pp.86~92 (2008)
  38. Dellinges MA, "A measurement of torque values obtained with hand-held drivers in a simulated clinical setting", J Prosthodont, 2, pp.212~214 (1993)
  39. Gross M, "Manual closing torque in five implant abutment systems : an in vitro comparative study", J Prosthet Dent, 81, pp.574~578 (1999)
  40. Jaarda MJ, "Providing optimum torque to implant prostheses : a pilot study", Implant Dent, 2, pp.50~52 (1993)
  41. Tan KB, "The effect of 3 torque delivery systems on gold screw preload at the gold cylinder-abutment screw joint", Int J Oral Maxillofac Implants, 17, pp.175~183 (2002)
  42. Johansson CB, "A removal torque and histomorphometric study of bone tissue reaction to commercially pure titanium and vitallium implant", Int J Oral Maxillofac Implants, 6, pp.437~441 (1991)
  43. Johansson CB, "A removal torque and histomorphometric study of commercially pure niobium and titanium implants in rabbit bone", Clin Oral Implants Res, 2, pp.24~29 (1991)
  44. Klokkevold PR, "Osseointegration enhanced by chemical etching of the titanium surface. A torque removal study in the rabbit", Clin Oral Implants Res, 8, pp.442~447 (1997)
  45. Buser D, "Removal torque values of titanium implants in the maxilla of miniature pigs", Int J Oral Maxillofac Implants, 13, pp.611~619 (1998)
  46. Buser D, "Interface shear strength of titanium implants with a sandblasted and acid-etched surface : a biomechanical study in the maxilla of miniature pigs", J Biomed Mater Res, 45, pp.75~83 (1999)
  47. Inadome T, "Comparison of bone-implant interface shear strength of hydroxyapatite-coated and alumina-coated metal implants", J Biomed Mater Res, 29, pp.19~24 (1995)
  48. Ellingsen JE, "Improved retention and bone-tolmplant contact with fluoride-modified titanium implants", Int J Oral Maxillofac Implants, 19, pp.659~666 (2004)
  49. Paepoemsin T, "Removal torque evaluation of three different abutment screws for single implant restorations after mechanical cyclic loading", Oral Implantol(Rome), 9, pp.213~221 (2016)
  50. Stüker RA, "Preload and torque removal evaluation of three different abutment screws for single standing implant restorations", J Appl Oral Sci, 16, pp.55~58 (2008)
  51. Ghanbarzadeh J, "Torque removal evaluation of screw in one-piece and two-piece abutments tightened with a handheld screwdriver", J Dent Mater Tech, 3, pp.11~15 (2013)
  52. Saliba FM, "A rationale method for evaluating unscrewing torque values of prosthetic screws in dental implants", J Appl Oral Sci, 19, pp.63~67 (2011)
  53. 황윤진, "임플란트 고정체의 인위적 비틀림 후 시간 경과에 따른 골재유착 반응에 관한 연구", 대한치과보철학회지, 48(04), pp.308~314 (2010), 대한치과보철학회[DOI]
  54. Koh YH, "Bone healing around screwshaped titanium implants with three different surface topographies", J Korean Acad Periodontol, 31, pp.41~55 (2001)
  55. Yi YA, "The evaluation of osseointegration of dental implant surface with different size of TiO 2 nanotube in rats", J Nanomater, 2, pp.1~10 (2015)
  56. Buser D, "Removal torque values of titanium implants in the maxilla of miniature pigs", Int J Oral Maxillofac Implants, 13, pp.611~619 (1998)
  57. Albayrak H, "Accuracy of torque-limiting devices : A comparative evaluation", J Prosthet Dent, 117, pp.81~86 (2017)
  58. Wadhwani CPK, "Testing and calibrating the mechanical-type toggle torque wrenches used in implant dentistry: A dental technique", J Prosthet Dent (2019)
  59. Kreissl ME, "Technical complications of implant-supported fixed partial dentures in partially edentulous cases after an average observation period of 5 years", Clin Oral Implants Res, 18, pp.720~726 (2007)
  60. Sananez A, "In vitro mechanical analysis of complete-arch mandibular implant-supported fixed prostheses abutment screws after cyclic loading", J Prosthet Dent, 113, pp.432~439 (2015)

관련 논문AI추천

이 간행물의 다른 논문 (5건)