The effect of thermo-mechanical fatigue on the retentive force and dimensional changes in polyetheretherketone clasps with different thickness and undercut
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
PURPOSE. Esthetic expectations have increased the use of polyetheretherketone (PEEK) clasps as alternatives to Cr-Co in removable partial dentures (RPDs). The objective of this study was to evaluate the retentive force and dimensional change of clasps with different thickness and undercut made from PEEK by the thermo-mechanical fatigue. MATERIALS AND METHODS. PEEK clasps (N = 48) with thicknesses of 1 or 1.50 mm and 48 premolar monolithic zirconia crowns with undercuts of 0.25 mm or 0.50 mm were fabricated. Samples are divided into four groups (C1-C4) and were subjected to 7200 thermal aging cycles (at 5 – 55°C). The changes in the retentive force and dimensions of the clasps were measured by micro-stress testing and micro-CT devices from five measurement points (M1 - M5). One-way ANOVA, paired t-test, two-way repeated ANOVA, and post-hoc tests were used to analyze the data (P < .05). RESULTS. The retentive forces of C1, C2, C3, and C4 groups in initial and final test were found to be 4.389-3.388 N, 4.67 - 3.396 N, 5.161 - 4.096 N, 5.459 - 4.141 N, respectively. The effects of retentive force of all PEEK clasps groups were significant decreased. Thermo-mechanical cycles caused significant dimensional changes at points with M2, M4, and M5, and abraded the clasp corners and increased the distance between the ends of the clasp, resulting in reduced retentive forces (P * = .016, P * = .042, P < .001, respectively). CONCLUSION. Thermo-mechanical aging decreases the retentive forces in PEEK clasps. Increasing the thickness and undercut amount of clasps decreases the amount of dimensional change. The values measured after aging are within the clinically acceptable limits.
Abstract
PURPOSE. Esthetic expectations have increased the use of polyetheretherketone (PEEK) clasps as alternatives to Cr-Co in removable partial dentures (RPDs). The objective of this study was to evaluate the retentive force and dimensional change of clasps with different thickness and undercut made from PEEK by the thermo-mechanical fatigue. MATERIALS AND METHODS. PEEK clasps (N = 48) with thicknesses of 1 or 1.50 mm and 48 premolar monolithic zirconia crowns with undercuts of 0.25 mm or 0.50 mm were fabricated. Samples are divided into four groups (C1-C4) and were subjected to 7200 thermal aging cycles (at 5 – 55°C). The changes in the retentive force and dimensions of the clasps were measured by micro-stress testing and micro-CT devices from five measurement points (M1 - M5). One-way ANOVA, paired t-test, two-way repeated ANOVA, and post-hoc tests were used to analyze the data (P < .05). RESULTS. The retentive forces of C1, C2, C3, and C4 groups in initial and final test were found to be 4.389-3.388 N, 4.67 - 3.396 N, 5.161 - 4.096 N, 5.459 - 4.141 N, respectively. The effects of retentive force of all PEEK clasps groups were significant decreased. Thermo-mechanical cycles caused significant dimensional changes at points with M2, M4, and M5, and abraded the clasp corners and increased the distance between the ends of the clasp, resulting in reduced retentive forces (P * = .016, P * = .042, P < .001, respectively). CONCLUSION. Thermo-mechanical aging decreases the retentive forces in PEEK clasps. Increasing the thickness and undercut amount of clasps decreases the amount of dimensional change. The values measured after aging are within the clinically acceptable limits.
참고문헌 (43)
- Donovan TE, "Esthetic considerations in removable prosthodontics", J Esthet Restor Dent, 13, pp.241~253 (2001)
- Vallittu PK, "Deflection fatigue of cobalt-chromium, titanium, and gold alloy cast denture clasp", J Prosthet Dent, 74, pp.412~419 (1995)
- 이정진, "Evaluation of effect of galvanic corrosion between nickel-chromium metal and titanium on ion release and cell toxicity", The Journal of Advanced of Prosthodontics, 7(2), pp.172~177 (2015), 대한치과보철학회[DOI]
- Mayinger F, "Retention force of polyetheretherketone and cobalt-chrome-molybdenum removable dental prosthesis clasps after artificial aging", Clin Oral Invest, 25, pp.3141~3149 (2021)
- Schwitalla AD, "Flexural behavior of PEEK materials for dental application", Dent Mater, 31, pp.1377~1384 (2015)
- Wenz LM, "In vitro biocompatibility of polyetheretherketone and polysulfone composites", J Biomed Mater Res, 24, pp.207~215 (1990)
- Wimmer T, "Two-body wear rate of PEEK, CAD", CAM resin composite and PMMA : effect of specimen geometries, antagonist materials and test set-up configuration, 2016, pp.32, e127~e136
- Wiesli MG, "High-performance polymers and their potential application as medical and oral implant materials : a review", Implant Dent, 24, pp.448~457 (2015)
- Peng TY, "Finite-element analysis and optimization of the mechanical properties of polyetheretherketone(PEEK)clasps for removable partial dentures", J Prosthodont Res, 64, pp.250~256 (2020)
- Papathanasiou I, "The use of PEEK in digital prosthodontics : A narrative review", BMC Oral Health, 20, pp.217~ (2020)
- Najeeb S, "Applications of polyetheretherketone(PEEK)in oral implantology and prosthodontics", J Prosthodont Res, 60, pp.12~19 (2016)
- Zoidis P, "The use of a modified poly-ether-ether-ketone (PEEK) as an alternative framework material for removable dental prostheses. a clinical report", J Prosthodont, 25, pp.580~584 (2016)
- Tannous F, "Retentive forces and fatigue resistance of thermoplastic resin clasps", Dent Mater, 28, pp.273~278 (2012)
- Bathala L, "The role of polyether ether ketone(peek)in dentistry-a review", J Med Life, 12, pp.5~9 (2019)
- Morris HF, "Stress-relaxation testing. Part IV: Clasp pattern dimen-sions and their influence on clasp behavior", J Prosthet Dent, 50, pp.319~326 (1983)
- Chrystie JA, "Principles of clasp retention : a review", Aust Dent J, 33, pp.96~100 (1988)
- Mahmoud A, "Deflection fatigue of Ti-6Al-7Nb, Co-Cr, and gold alloy cast clasps", J Prosthet Dent, 93, pp.183~188 (2005)
- Vallittu PK, "Duration of induction melting of cobalt-chromium alloy and its effect on resistance to deflection fatigue of cast denture clasps", J Prosthet Dent, 75, pp.332~336 (1996)
- Vallittu PK, "Deflection fatigue of cobalt-chromium, titanium, and gold alloy cast denture clasp", J Prosthet Dent, 74, pp.412~419 (1995)
- de Faria Vasconcelos K, "MicroCT assessment of bone microarchitecture in implant sites reconstructed with autogenous and xenogenous grafts : a pilot study", Clin Oral Implants Res, 28, pp.308~313 (2017)
- Eroğlu Z, "Fatigue behavior of zirconia-ceramic, galvano-ceramic, and porcelain-fusedto-metal fixed partial dentures", J Prosthodont, 22, pp.516~522 (2013)
- Kümbüloğlu Ö, "Retention and deformation of cobalt-chromium and high-impact polyamide clasps", Meandros Med Dent J, 19, pp.25~31 (2018)
- Jiang N, "Effects of clasp retention forces and abrasion on different cast crowns", J Prosthet Dent, 111, pp.493~498 (2014)
- Cheng H, "Cyclic fatigue properties of cobalt-chromium alloy clasps for partial removable dental prostheses", J Prosthet Dent, 104, pp.389~396 (2010)
- 백장현, "Fabrication of a CAD", CAM monolithic zirconia crown to fit an existing partial removable dental prosthesis, 2016, pp.8(4), 329~332[DOI]
- Pereira JR, "The effect of post material on the characteristic strength of fatigued endodontically treated teeth", J Prosthet Dent, 112, pp.1225~1230 (2014)
- Arda T, "An in vitro comparison of retentive force and deformation of acetal resin and cobalt-chromium clasps", J Prosthet Dent, 94, pp.267~274 (2005)
- Lümkemann N, "Bonding to different PEEK compositions: the Impact of Dental Light Curing Units", Materials(Basel), 10, pp.67~ (2017)
- "Turcosa Analytics Ltd. Co" (2021)[URL]
- Davenport JC, "Retention", Br Dent J, 189, pp.646~657 (2000)
- Bridgeman JT, "Comparison of titanium and cobalt-chromium removable partial denture clasps", J Prosthet Dent, 78, pp.187~193 (1997)
- Kim D, "Comparison of cast Ti-Ni alloy clasp retention with conventional removable partial denture clasps", J Prosthet Dent, 91, pp.374~382 (2004)
- Osada H, "Influence of thickness and undercut of thermoplastic resin clasps on retentive force", Dent Mater J, 32, pp.381~389 (2013)
- Koike M, "Fatigue life of cast titanium alloys under simulated denture framework displacements", Metall Mater Trans A Phys Metall Mater Sci, 44, pp.1034~1044 (2013)
- de Torres ÉM, "Effect of acetyl resin retentive arms on the retentive force of circumferential clasps : an in vitro study", J Prosthodont Res, 56, pp.216~221 (2012)
- Carr AB, "McCracken’s removable partial prosthodontics", pp.25~31 (2005), Mosby
- Henriques GEP, "Soldering and remelting influence on fatigue strength of cobalt-chromium alloys", J Prosthet Dent, 78, pp.146~152 (1997)
- Souza JE, "Retention strength of cobalt-chromium vs nickel-chromium titanium vs CP titanium in a cast framework association of removable partial overdenture", J Contemp Dent Pract, 12, pp.179~186 (2011)
- Kim SY, "Effect of cyclic bend loading on a cobalt-chromium clasp fabricated by direct metal laser sintering", J Prosthet Dent, 119, pp.1027.e1~1027.e7 (2018)
- Sato Y, "Analysis of stiffness and stress in I-bar clasps", J Oral Rehabil, 28, pp.596~600 (2001)
- Wagner B, "Clinical evaluation of removable partial dentures 10 years after insertion: success rates, hygienic problems, and technical failures", Clin Oral Investig, 4, pp.74~80 (2000)
- Boerckel JD, "Microcomputed tomography : approaches and applications in bioengineering", Stem Cell Res Ther, 5, pp.144~ (2014)
- Marie A, "Deformation and retentive force following in vitro cyclic fatigue of cobalt-chrome and aryl ketone polymer(AKP)clasps", Dent Mater, 35, pp.e113~e121 (2019)
