본문 바로가기
KERD
논문KCI 등재

Marginal bone level change during sequential loading periods of partial edentulous rehabilitation using immediately loaded self-tapping implants: a 6.5-year retrospective study

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

PURPOSE. A large number of studies have suggested the practicability and predictability of immediate implant function, but few studies have reported marginal bone level changes during sequential loading periods. The purpose of this study was to evaluate the marginal bone remodeling of immediately loaded self-tapping implants both at each time point and during each loading period between two time points. MATERIALS AND METHODS. The patients included in this retrospective study were treated with immediately loaded NobelSpeedy Replace implants between August 2008 and July 2009. Differences in the marginal bone level (MBL) at each time point and the marginal bone level change (ΔMBL) between two time points were analyzed with Bonferroni correction (P < .05). RESULTS. Overall, 24 patients (mean age, 47.3 ± 12.8 years) with 42 immediately loaded implants and a median follow-up of 6.5 years (IQR, 67.8 months) were included. The cumulative survival rate after 10 - 12 years was 95.2%. Continuous but slow marginal bone loss was observed during long-term follow-up. MBL at both 7.5 years and 11 years was significantly lower than that at loading, 6 months, 2 years and 4 years (P < .05). No bone loss difference was found in any period before 4 years of follow up (P > .05). The loading period of 4 years to 7.5 years showed the largest ΔMBL compared to those of other time periods (P < .05). CONCLUSION. Slight bone loss occurred continuously, and more radical changes of marginal bone can be observed during the period of 4-7.5 years. Thus, long-term effective follow-up of immediately loaded implants is needed.

Abstract

PURPOSE. A large number of studies have suggested the practicability and predictability of immediate implant function, but few studies have reported marginal bone level changes during sequential loading periods. The purpose of this study was to evaluate the marginal bone remodeling of immediately loaded self-tapping implants both at each time point and during each loading period between two time points. MATERIALS AND METHODS. The patients included in this retrospective study were treated with immediately loaded NobelSpeedy Replace implants between August 2008 and July 2009. Differences in the marginal bone level (MBL) at each time point and the marginal bone level change (ΔMBL) between two time points were analyzed with Bonferroni correction (P < .05). RESULTS. Overall, 24 patients (mean age, 47.3 ± 12.8 years) with 42 immediately loaded implants and a median follow-up of 6.5 years (IQR, 67.8 months) were included. The cumulative survival rate after 10 - 12 years was 95.2%. Continuous but slow marginal bone loss was observed during long-term follow-up. MBL at both 7.5 years and 11 years was significantly lower than that at loading, 6 months, 2 years and 4 years (P < .05). No bone loss difference was found in any period before 4 years of follow up (P > .05). The loading period of 4 years to 7.5 years showed the largest ΔMBL compared to those of other time periods (P < .05). CONCLUSION. Slight bone loss occurred continuously, and more radical changes of marginal bone can be observed during the period of 4-7.5 years. Thus, long-term effective follow-up of immediately loaded implants is needed.

참고문헌 (45)

  1. Brånemark PI, "Intra-osseous anchorage of dental prostheses. I. Experimental studies", Scand J Plast Reconstr Surg, 3, pp.81~100 (1969)
  2. Wennerberg A, "Longterm clinical outcome of implants with different surface modifications", Eur J Oral Implantol, 11, pp.S123~S136 (2018)
  3. Albrektsson T, "The long-term efficacy of currently used dental implants : a review and proposed criteria of success", Int J Oral Maxillofac Implants, 1, pp.11~25 (1986)
  4. Chrcanovic BR, "A retrospective study on clinical and radiological outcomes of oral implants in patients followed up for a minimum of 20 years", Clin Implant Dent Relat Res, 20, pp.199~207 (2018)
  5. Coli P, "On marginal bone level changes around dental implants", Clin Implant Dent Relat Res, 23, pp.159~169 (2021)
  6. Chen J, "Immediate versus early or conventional loading dental implants with fixed prostheses : A systematic review and meta-analysis of randomized controlled clinical trials", J Prosthet Dent, 122, pp.516~536 (2019)
  7. Cannizzaro G, "Immediate functional loading of implants placed with flapless surgery versus conventional implants in partially edentulous patients : a 3-year randomized controlled clinical trial", Int J Oral Maxillofac Implants, 23, pp.867~875 (2008)
  8. Galli F, "Immediate non-occlusal vs. early loading of dental implants in partially edentulous patients: a multicentre randomized clinical trial. Peri-implant bone and soft-tissue levels", Clin Oral Implants Res, 19, pp.546~552 (2008)
  9. Trbakovic A, "Eight to eleven-year follow-up of immediately loaded implants placed in edentulous maxillae with compromised bone volume and poor bone quality : A prospective cohort study", Clin Implant Dent Relat Res, 22, pp.69~76 (2020)
  10. Rai S, "Immediately loaded single unit dental implants : a clinical study", J Pharm Bioallied Sci, 12, pp.S245~S253 (2020)
  11. Amato F, "Immediate loading of fixed partial dental prostheses on extra-short and short implants in patients with severe atrophy of the posterior maxilla or mandible : an up-to-4-year clinical study", Int J Oral Maxillofac Implants, 35, pp.607~615 (2020)
  12. Del Giudice R, "Implant insertion torque value in immediate loading : a retrospective study", Med Oral Patol Oral Cir Bucal, 24, pp.e398~e403 (2019)
  13. Bavetta G, "A retrospective study on insertion torque and implant stability quotient(ISQ)as stability parameters for immediate loading of implants in fresh extraction sockets", Biomed Res Int, 2019, pp.9720419~ (2019)
  14. Albrektsson T, "On osseointegration in relation to implant surfaces", Clin Implant Dent Relat Res, 21, pp.4~7 (2019)
  15. Jungner M, "A retrospective comparison of oxidized and turned implants with respect to implant survival, marginal bone level and peri-implant soft tissue conditions after at least 5years in function", Clin Implant Dent Relat Res, 16, pp.230~237 (2014)
  16. Maló P, "Complete edentulous rehabilitation using an immediate function protocol and an implant design featuring a straight body, anodically oxidized surface, and narrow tip with engaging threads extending to the apex of the implant: a 5-year retrospective clinical study", Int J Oral Maxillofac Implants, 31, pp.153~161 (2016)
  17. Maló P, "A pilot study of complete edentulous rehabilitation with immediate function using a new implant design : case series", Clin Implant Dent Relat Res, 8, pp.223~232 (2006)
  18. Agliardi EL, "Immediate fixed rehabilitation of the edentulous maxilla : a prospective clinical and radiological study after 3 years of loading", Clin Implant Dent Relat Res, 16, pp.292~302 (2014)
  19. Coutant JC, "Assessment of the correlation between implant stability and bone density by computed tomography and resonance frequency analysis in fresh cadavers", Int J Oral Maxillofac Implants, 29, pp.1264~1270 (2014)
  20. Maló P, "Posterior maxillary implants inserted with bicortical anchorage and placed in immediate function for partial or complete edentulous rehabilitations. A retrospective clinical study with a median follow-up of 7 years", Oral Maxillofac Surg, 19, pp.19~27 (2015)
  21. Puterman I, "Biological adaptation to misfits of immediately loaded fixed prostheses following computer-guided surgery", J Prosthodont, 21, pp.185~190 (2012)
  22. Lombardi T, "Factors influencing early marginal bone loss around dental implants positioned subcrestally : a multicenter prospective clinical study", J Clin Med, 8, pp.1168~ (2019)
  23. Rattanapanich P, "Comparative study between an immediate loading protocol using the digital workflow and a conventional protocol for dental implant treatment : a randomized clinical trial", J Clin Med, 8, pp.622~ (2019)
  24. Zhu Y, "Clinical efficacy of early loading versus conventional loading of dental implants", Sci Rep, 5, pp.15995~ (2015)
  25. Bambini F, "Biological oriented immediate loading: a new mathematical implant vertical insertion protocol, five-year follow-up study", Materials(Basel), 14, pp.387~ (2021)
  26. Lemos BF, "Effects of different undersizing site preparations on implant stability", Int J Environ Res Public Health, 17, pp.8965~ (2020)
  27. Planinić D, "Comparison of different surgical procedures on the stability of dental implants in posterior maxilla : A randomized clinical study", J Stomatol Oral Maxillofac Surg, 122, pp.487~493 (2021)
  28. Vogl S, "Immediate occlusal vs nonocclusal loading of implants : A randomized prospective clinical pilot study and patient centered outcome after 36 months", Clin Implant Dent Relat Res, 21, pp.766~774 (2019)
  29. Brunski JB, "In vivo bone response to biomechanical loading at the bone", dental-implant interface, 1999, pp.13, 99~119
  30. Ericsson I, "Immediate functional loading of Brånemark single tooth implants. An 18 months’ clinical pilot follow-up study", Clin Oral Implants Res, 11, pp.26~33 (2000)
  31. Rao W, "Single mandibular first molar implants with flapless guided surgery and immediate function : preliminary clinical and radiographic results of a prospective study", J Prosthet Dent, 97, pp.S3~S14 (2007)
  32. Donati M, "Immediate functional loading of implants in single tooth replacement : a prospective clinical multicenter study", Clin Oral Implants Res, 19, pp.740~748 (2008)
  33. Benic GI, "Loading protocols for single-implant crowns : a systematic review and meta-analysis", Int J Oral Maxillofac Implants, 29, pp.222~238 (2014)
  34. Brizuela-Velasco A, "The functional loading of implants increases their stability : A retrospective clinical study", Clin Implant Dent Relat Res, 21, pp.122~129 (2019)
  35. Güncü MB, "In-patient comparison of immediate and conventional loaded implants in mandibular molar sites within 12 months", Clin Oral Implants Res, 19, pp.335~341 (2008)
  36. Becker W, "Survival rates and bone level changes around porous oxide-coated implants(TiUnite™)", Clin Implant Dent Relat Res, 15, pp.654~660 (2013)
  37. Monje A, "A systematic review on marginal bone loss around short dental implants(<10 mm)for implant-supported fixed prostheses", Clin Oral Implants Res, 25, pp.1119~1124 (2014)
  38. Urdaneta RA, "The effect of opposing structures, natural teeth vs. implants on crestal bone levels surrounding single-tooth implants", Clin Oral Implants Res, 25, pp.e179~e188 (2014)
  39. Degidi M, "10-year follow-up of immediately loaded implants with TiUnite porous anodized surface", Clin Implant Dent Relat Res, 14, pp.828~838 (2012)
  40. Andersen E, "Immediate loading of single-tooth ITI implants in the anterior maxilla : a prospective 5-year pilot study", Clin Oral Implants Res, 13, pp.281~287 (2002)
  41. Donati M, "Marginal bone preservation in single-tooth replacement : a 5-year prospective clinical multicenter study", Clin Implant Dent Relat Res, 17, pp.425~434 (2015)
  42. Berglundh T, "Bone reactions to longstanding functional load at implants : an experimental study in dogs", J Clin Periodontol, 32, pp.925~932 (2005)
  43. Cooper L, "A multicenter 12-month evaluation of single-tooth implants restored 3 weeks after 1-stage surgery", Int J Oral Maxillofac Implants, 16, pp.182~192 (2001)
  44. Albrektsson T, "Crestal bone loss and oral implants", Clin Implant Dent Relat Res, 14, pp.783~791 (2012)
  45. Mura P, "Immediate placement of tapered implants with a moderately rough anodized surface and smooth collar in fresh extraction sockets : A retrospective analysis with 10-year follow-up", Clin Implant Dent Relat Res, 21, pp.272~277 (2019)

관련 논문AI추천

Comparison of peri-implant marginal bone level changes between tapered and straight implant designs: 5-year follow-up results박한, 문익상, 신수정, 윤정호, 이동원, 정주령, 허종기대한치주과학회 · Journal of Periodontal & Implant Science2021 · 제51권 제6호The feasibility of immediately loading dental implants in edentulous jawsAnders Henningsen, Aria Wahidi, Frank Kornmann, Lan Kluwe, Max Heiland, Ralf Smeets, Till Gerlach대한치주과학회 · Journal of Periodontal & Implant Science2016 · 제46권 제4호Marginal bone level changes in association with different vertical implant positions: a 3-year retrospective study김연태, 이재홍, 임규형, 정성념대한치주과학회 · Journal of Periodontal & Implant Science2017 · 제47권 제4호Marginal bony changes in relation to different vertical positions of dental implants엄흥식, 이민구, 이재관, 이정명, 장범석대한치주과학회 · Journal of Periodontal & Implant Science2010 · 제40권 제5호Bone-level implants placed in the anterior maxilla: an open-label, single-arm observational study김봉주, 김선경, 김성민, 박종철, 이종호, 팽강미, EnFeng Gao, Wei-Hong Hei대한치주과학회 · Journal of Periodontal & Implant Science2017 · 제47권 제5호Implant success rates in full-arch rehabilitations supported by upright and tilted implants: a retrospective investigation with up to five years of follow-upAndrea Rodolfi, Bruno Barbaro, Luca Francetti, Nicolò Cavalli, Silvio Taschieri, Stefano Corbella대한치주과학회 · Journal of Periodontal & Implant Science2015 · 제45권 제6호

이 간행물의 다른 논문 (5건)