본문 바로가기
KERD
논문KCI 등재

Comparison of fit and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

PURPOSE. This study aims to clinically compare the fitness and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems. MATERIALS AND METHODS. Total of 40 patients were enrolled in this study, and 9 different zirconia crowns were prepared per patient. Each crown was made through the cross-application of 3 different design software (EZIS VR, 3Shape Dental System, Exocad) with 3 different processing devices (Aegis HM, Trione Z, Motion 2). The marginal gap, absolute marginal discrepancy, internal gap(axial, line angle, occlusal) by a silicone replica technique were measured to compare the fit of the crown. The scanned inner and outer surfaces of the crowns were compared to CAD data using 3D metrology software to evaluate trueness. RESULTS. There were significant differences in the marginal gap, absolute marginal discrepancy, axial and line angle internal gap among the groups (P < .05) in the comparison of fit. There was no statistically significant difference among the groups in terms of occlusal internal gap. The trueness ranged from 36.19 to 43.78 μm but there was no statistically significant difference within the groups (P > .05). CONCLUSION. All 9 groups showed clinically acceptable level of marginal gaps ranging from 74.26 to 112.20 μm in terms of fit comparison. In the comparison of trueness, no significant difference within each group was spotted. Within the limitation of this study, open CAD-CAM systems used in this study can be assembled properly to fabricate zirconia crown.

Abstract

PURPOSE. This study aims to clinically compare the fitness and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems. MATERIALS AND METHODS. Total of 40 patients were enrolled in this study, and 9 different zirconia crowns were prepared per patient. Each crown was made through the cross-application of 3 different design software (EZIS VR, 3Shape Dental System, Exocad) with 3 different processing devices (Aegis HM, Trione Z, Motion 2). The marginal gap, absolute marginal discrepancy, internal gap(axial, line angle, occlusal) by a silicone replica technique were measured to compare the fit of the crown. The scanned inner and outer surfaces of the crowns were compared to CAD data using 3D metrology software to evaluate trueness. RESULTS. There were significant differences in the marginal gap, absolute marginal discrepancy, axial and line angle internal gap among the groups (P < .05) in the comparison of fit. There was no statistically significant difference among the groups in terms of occlusal internal gap. The trueness ranged from 36.19 to 43.78 μm but there was no statistically significant difference within the groups (P > .05). CONCLUSION. All 9 groups showed clinically acceptable level of marginal gaps ranging from 74.26 to 112.20 μm in terms of fit comparison. In the comparison of trueness, no significant difference within each group was spotted. Within the limitation of this study, open CAD-CAM systems used in this study can be assembled properly to fabricate zirconia crown.

참고문헌 (50)

  1. Beuer F, "Digital dentistry : an overview of recent developments for CAD", CAM generated restorations, 2008, pp.204, 505~511
  2. Jang D, "A comparative study of the fitness and trueness of a three-unit fixed dental prosthesis fabricated using two digital workflows", Appl Sci, 9, pp.2778~ (2019)
  3. Kricheldorf F, "Analysis of vertical marginal discrepancy in feldspathic porcelain crowns manufactured with different CAD", CAM systems : Closed and open, 2018, pp.12, 123~128
  4. Alqahtani F, "Marginal fit of all-ceramic crowns fabricated using two extraoral CAD", CAM systems in comparison with the conventional technique, 2017, pp.9, 13~18
  5. Hunter AJ, "Gingival margins for crowns: a review and discussion. Part II: Discrepancies and configurations", J Prosthet Dent, 64, pp.636~642 (1990)
  6. Valderrama S, "A comparison of the marginal and internal adaptation of titanium and gold-platinum-palladium metal ceramic crowns", Int J Prosthodont, 8, pp.29~37 (1995)
  7. Felton DA, "Effect of in vivo crown margin discrepancies on periodontal health", J Prosthet Dent, 65, pp.357~364 (1991)
  8. Wang CJ, "Effects of cement, cement space, marginal design, seating aid materials, and seating force on crown cementation", J Prosthet Dent, 67, pp.786~790 (1992)
  9. Piemjai M, "Effect of seating force, margin design, and cement on marginal seal and retention of complete metal crowns", Int J Prosthodont, 14, pp.412~416 (2001)
  10. Ahn JJ, "Clinical evaluation of the fit of lithium disilicate crowns fabricated with three different CAD", CAM systems, 2022, pp.127, 239~247
  11. Björn AL, "Marginal fit of restorations and its relation to periodontal bone level. II. Crowns", Odontol Revy, 21, pp.337~346 (1970)
  12. Paffenbarger GC, "American dental association specification No. 8 for dental zinc phosphate cement", J American Dent Assoc Dent Cosmos, 24, pp.2019~2023 (1937)
  13. Sorensen SE, "Gingival and alveolar bone reaction to marginal fit of subgingival crown margins", Scand J Dent Res, 94, pp.109~114 (1986)
  14. McLean JW, "The estimation of cement film thickness by an in vivo technique", Br Dent J, 131, pp.107~111 (1971)
  15. Kydd WL, "Marginal leakage of cast gold crowns luted with zinc phosphate cement : an in vivo study", J Prosthet Dent, 75, pp.9~13 (1996)
  16. Schriwer C, "Monolithic zirconia dental crowns. Internal fit, margin quality, fracture mode and load at fracture", Dent Mater, 33, pp.1012~1020 (2017)
  17. Tinschert J, "Status of current CAD", CAM technology in dental medicine, 2004, pp.7, 25~45
  18. Lee KB, "Marginal and internal fit of all-ceramic crowns fabricated with two different CAD", CAM systems, 2008, pp.27, 422~426
  19. Zimmermann M, "New CAD", CAM materials and blocks for chairside procedures, 2013, pp.16, 173~181
  20. Naveau A, "Zirconia abutments in the anterior region : A systematic review of mechanical and esthetic outcomes", J Prosthet Dent, 121, pp.775~781 (2019)
  21. Deng Y, "Characterization of damage modes in dental ceramic bilayer structures", J Biomed Mater Res, 63, pp.137~145 (2002)
  22. Kelly JR, "Stabilized zirconia as a structural ceramic : an overview", Dent Mater, 24, pp.289~298 (2008)
  23. Mously HA, "Marginal and internal adaptation of ceramic crown restorations fabricated with CAD", CAM technology and the heat-press technique, 2014, pp.112, 249~256
  24. Rödiger M, "Fitting accuracy of zirconia single crowns produced via digital and conventional impressions-a clinical comparative study", Clin Oral Investig, 21, pp.579~587 (2017)
  25. Holmes JR, "Considerations in measurement of marginal fit", J Prosthet Dent, 62, pp.405~408 (1989)
  26. Son K, "Comparative study of the trueness of the inner surface of crowns fabricated from three types of lithium disilicate blocks", Appl Sci, 9, pp.1798~ (2019)
  27. "ISO 12836. Dentistry - Digitizing devices for CAD/CAM systems for indirect dental restorations - Test methods for assessing accuracy" (2015)[URL]
  28. Bindl A, "Fit of all-ceramic posterior fixed partial denture frameworks in vitro", Int J Periodont Restor Dent, 27, pp.567~575 (2007)
  29. Sorensen JA, "A standardized method for determination of crown margin fidelity", J Prosthet Dent, 64, pp.18~24 (1990)
  30. Rahme HY, "In vitro evaluation of the"replica technique"in the measurement of the fit of Procera crowns", J Contemp Dent Pract, 9, pp.25~32 (2008)
  31. Pera P, "In vitro marginal adaptation of alumina porcelain ceramic crowns", J Prosthet Dent, 72, pp.585~590 (1994)
  32. Koo JY, "Marginal fidelities according to the margin types of all ceramic crowns", J Korean Acad Prosthodont, 35, pp.445~457 (1997)
  33. Boitelle P, "A systematic review of CAD", CAM fit restoration evaluations, 2014, pp.41, 853~874
  34. Reich S, "Measurement of cement thickness under lithium disilicate crowns using an impression material technique", Clin Oral Investig, 15, pp.521~526 (2011)
  35. Ahrberg D, "Evaluation of fit and efficiency of CAD", CAM fabricated all-ceramic restorations based on direct and indirect digitalization:a double-blinded, randomized clinical trial, 2016, pp.20, 291~300
  36. Pradíes G, "Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions based on wavefront sampling technology", J Dent, 43, pp.201~208 (2015)
  37. White SN, "Effect of seating force on film thickness of new adhesive luting agents", J Prosthet Dent, 68, pp.476~481 (1992)
  38. Lee B, "Evaluation of the fit of zirconia copings fabricated by direct and indirect digital scanning procedures", J Prosthet Dent, 120, pp.225~231 (2018)
  39. Reich S, "Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD", CAM systems, 2005, pp.113, 174~179
  40. Carbajal Mejía JB, "Marginal and internal fit of CAD", CAM crowns fabricated over reverse tapered preparations, 2019, pp.28, e477~84
  41. Bornemann G, "Innovative method for the analysis of the internal 3D fitting accuracy of Cerec-3 crowns", Int J Comput Dent, 5, pp.177~182 (2002)
  42. Wang W, "Trueness analysis of zirconia crowns fabricated with 3-dimensional printing", J Prosthet Dent, 121, pp.285~291 (2019)
  43. Moldovan O, "Three-dimensional fit of CAD", CAM-made zirconia copings, 2011, pp.27, 1273~1278
  44. Alghazzawi TF, "Advancements in CAD", CAM technology : Options for practical implementation, 2016, pp.60, 72~84
  45. Kirsch C, "Trueness of four different milling procedures used in dental CAD", CAM systems, 2017, pp.21, 551~558
  46. Bosch G, "A 3-dimensional accuracy analysis of chairside CAD", CAM milling processes, 2014, pp.112, 1425~1431
  47. Ben-Izhack G, "(In-vitro comparison between closed versus open CAD", CAM systems)Comparison between closed and open CAD, Appl Sci, pp.2021, 11[DOI]
  48. Kunii J, "Effect of sintering on the marginal and internal fit of CAD", CAM-fabricated zirconia frameworks, 2007, pp.26, 820~826
  49. 박진영, "Evaluation of the marginal and internal gaps of three different dental prostheses: comparison of the silicone replica technique and three-dimensional superimposition analysis", The Journal of Advanced of Prosthodontics, 9(3), pp.159~169 (2017), 대한치과보철학회[DOI]
  50. Ahn JJ, "Comparison of clinical fit of three-unit zirconia fixed prostheses fabricated using chairside and labside CAD", CAM systems, 2020, pp.15, 239~242

관련 논문AI추천

Comparison of the fit accuracy of zirconia-based prostheses generated by two CAD/CAM systems조진현, 하석준대한치과보철학회 · The Journal of Advanced of Prosthodontics2016 · 제8권 제6호Assessment of the fit of zirconia-based prostheses fabricated with two different scan methods조진현, 최현석대한치과보철학회 · 대한치과보철학회지2017 · 제55권 제2호Evaluation of marginal fit of 2 CAD-CAM anatomic contour zirconia crown systems and lithium disilicate glass-ceramic crown박상원, 박지희, 오계정, 윤귀덕, 임현필, 지민경대한치과보철학회 · The Journal of Advanced of Prosthodontics2015 · 제7권 제4호다양한CAD/CAM 시스템으로 제작된 3 본 고정성 가공의치 지르코니아 코어의 변연 및 내면 적합도 평가김영수, 김우식, 김종은, 김하영, 신상완, 이정열, 전영찬, 허중보대한치과보철학회 · 대한치과보철학회지2011 · 제49권 제03호Marginal fit of anterior 3-unit fixed partial zirconia restorations using different CAD/CAM systems권택가, 김성훈, 송태진, 양재호, 여인성, 이재봉, 한중석대한치과보철학회 · The Journal of Advanced of Prosthodontics2013 · 제5권 제3호Comparison of three-dimensional digital technique with twodimensional replica method for measuring marginal and internal fit of full coverage restorationsMahya Hasanzade, Marzieh Alikhasi, Naeime Moslemian, Soudabeh Koulivand대한치과보철학회 · The Journal of Advanced of Prosthodontics2020 · 제12권 제3호

이 간행물의 다른 논문 (5건)