In vitro evaluation of the effect of auxiliary geometric device on measurement trueness and scanning time in fullarch implant impressions

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

PURPOSE. This in vitro study aimed to evaluate the effect of clinically practical auxiliary geometric devices (AGD) on measurement trueness and scan time in full-arch implant-supported prostheses, focusing on different intraoral scanners (IOS) and implant angulations. MATERIALS AND METHODS. Four implants were planned in an edentulous maxillary arch and divided into two groups based on posterior implant angulation: Model A (Parallel) and Model B (30°). Each model was evaluated under three auxiliary geometric devices (AGD) application types (std, agd1, agd2), and scanned using three different ıintraoral scanners (IOSs) [3Shape Trios 3 (T), Medit i700 (M), and Cerec Primescan (PS)], resulting in nine groups per model (n = 10). Scanning times and faulty scans were recorded. A conventional impression (CON) was taken as a control and digitized with a desktop scanner. Trueness was analyzed using Geomagic Control X, with statistical significance set at P < .05. RESULTS. Group B had higher RMS values than Group A (40.3 µm vs. 34.7 µm). T_std in Group A (51.4 µm) and T_std (53.1 µm) and Con (50.7 µm) in Group B exceeded the acceptable deviation limit. AGDs reduced deviations to acceptable levels in the Trios 3. The Primescan scanner had the shortest scanning times. AGD use, especially in T_agd2 and M_agd2, shortened scan times and eliminated erroneous scans. CONCLUSION. The use of AGD has a significant impact on scanners’ scanning trueness and time. [J Adv Prosthodont 2025;17:197-209]

Abstract

PURPOSE. This in vitro study aimed to evaluate the effect of clinically practical auxiliary geometric devices (AGD) on measurement trueness and scan time in full-arch implant-supported prostheses, focusing on different intraoral scanners (IOS) and implant angulations. MATERIALS AND METHODS. Four implants were planned in an edentulous maxillary arch and divided into two groups based on posterior implant angulation: Model A (Parallel) and Model B (30°). Each model was evaluated under three auxiliary geometric devices (AGD) application types (std, agd1, agd2), and scanned using three different ıintraoral scanners (IOSs) [3Shape Trios 3 (T), Medit i700 (M), and Cerec Primescan (PS)], resulting in nine groups per model (n = 10). Scanning times and faulty scans were recorded. A conventional impression (CON) was taken as a control and digitized with a desktop scanner. Trueness was analyzed using Geomagic Control X, with statistical significance set at P < .05. RESULTS. Group B had higher RMS values than Group A (40.3 µm vs. 34.7 µm). T_std in Group A (51.4 µm) and T_std (53.1 µm) and Con (50.7 µm) in Group B exceeded the acceptable deviation limit. AGDs reduced deviations to acceptable levels in the Trios 3. The Primescan scanner had the shortest scanning times. AGD use, especially in T_agd2 and M_agd2, shortened scan times and eliminated erroneous scans. CONCLUSION. The use of AGD has a significant impact on scanners’ scanning trueness and time. [J Adv Prosthodont 2025;17:197-209]

관련 논문AI추천

Comparison of 3D accuracy of three different digital intraoral scanners in full-arch implant impressionsFunda Bayindir, Ismail Hakki Korkmaz, Ozcan Akkal대한치과보철학회 · The Journal of Advanced of Prosthodontics2023 · 제15권 제4호Effect of reference objects on the accuracy of digital implant impressions in partially edentulous archesAgnė Gedrimienė, Darius Jegelevičius, Justinas Pletkus, Liudas Auškalnis, Mutlu Özcan, Mykolas Akulauskas, Tan Fırat Eyüboğlu, Vygandas Rutkūnas대한치과보철학회 · The Journal of Advanced of Prosthodontics2024 · 제16권 제5호Effects of inter-implant distance on the accuracy of intraoral scanner: An in vitro studyChuchai Anunmana, Prakan Thanasrisuebwong, Tharathip Kulchotirat대한치과보철학회 · The Journal of Advanced of Prosthodontics2021 · 제13권 제2호Effect of angulation on the 3D trueness of conventional and digital implant impressions for multi-unit restorationsDilem Toksoy, Oguz Ozan, Özay Önöral, Sevcan Kurtulmus-Yilmaz대한치과보철학회 · The Journal of Advanced of Prosthodontics2023 · 제15권 제6호Comparison of Accuracy in Digital Implant Impression using Dedicated and Compatible Scanbodies김준성, 손미경, 장근운, 허유리대한구강악안면임플란트학회 · 대한구강악안면임플란트학회지2022 · 제26권 제1호Accuracy of digital and conventional dental implant impressions for fixed partial dentures: A comparative clinical studyAgne Gedrimiene, Rimas Adaskevicius, Vygandas Rutkunas대한치과보철학회 · The Journal of Advanced of Prosthodontics2019 · 제11권 제5호

이 간행물의 다른 논문 (5건)