본문 바로가기
KERD
논문KCI 등재

Effect of angulation on the 3D trueness of conventional and digital implant impressions for multi-unit restorations

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Purpose. The study aimed to determine the influence of implant angulation on the trueness of multi-unit implant impressions taken through different techniques and strategies. Materials and Methods. As reference models, three partially edentulous mandibular models (Model 1: No angulation; Model 2: No angulation for #33, 15-degree distal angulation for #35 and #37; Model 3: No angulation for #33, 25-degree distal angulation for #35 and #37) were created by modifying the angulations of implant analogues. Using a lab scanner, these reference models were scanned. The obtained data were preserved and utilized as virtual references. Three intraoral scanning (IOS) strategies: IOS-Omnicam, ISO-Quadrant, and IOS-Consecutive, as well as two traaditional techniques: splinted open tray (OT) and closed tray (CT), were used to create impressions from each reference model. The best-fit alignment approach was used to sequentially superimpose the reference and test scan data. Computations and statistical analysis of angular (AD), linear (LD), and 3D deviations (RMS) were performed. Results. Model type, impression technique, as well as interaction factor, all demonstrated a significant influence on AD and LD values for all implant locations (P < .05). The Model 1 and SOT techniques displayed the lowest mean AD and LD values across all implant locations. When considering interaction factors, CT-Model 3 and SOT-Model 1 exhibited the highest and lowest mean AD and LD values, respectively. Model type, impression technique, and interaction factor all revealed significant effects on RMS values (P ≤ .001). CT-Model 3 and SOT-Model 1 presented the highest and lowest mean RMS values, respectively. Conclusion. Splinted-OT and IOS-Omnicam are recommended for multi-unit implant impressions to enhance trueness, potentially benefiting subsequent manufacturing stages.

Abstract

Purpose. The study aimed to determine the influence of implant angulation on the trueness of multi-unit implant impressions taken through different techniques and strategies. Materials and Methods. As reference models, three partially edentulous mandibular models (Model 1: No angulation; Model 2: No angulation for #33, 15-degree distal angulation for #35 and #37; Model 3: No angulation for #33, 25-degree distal angulation for #35 and #37) were created by modifying the angulations of implant analogues. Using a lab scanner, these reference models were scanned. The obtained data were preserved and utilized as virtual references. Three intraoral scanning (IOS) strategies: IOS-Omnicam, ISO-Quadrant, and IOS-Consecutive, as well as two traaditional techniques: splinted open tray (OT) and closed tray (CT), were used to create impressions from each reference model. The best-fit alignment approach was used to sequentially superimpose the reference and test scan data. Computations and statistical analysis of angular (AD), linear (LD), and 3D deviations (RMS) were performed. Results. Model type, impression technique, as well as interaction factor, all demonstrated a significant influence on AD and LD values for all implant locations (P < .05). The Model 1 and SOT techniques displayed the lowest mean AD and LD values across all implant locations. When considering interaction factors, CT-Model 3 and SOT-Model 1 exhibited the highest and lowest mean AD and LD values, respectively. Model type, impression technique, and interaction factor all revealed significant effects on RMS values (P ≤ .001). CT-Model 3 and SOT-Model 1 presented the highest and lowest mean RMS values, respectively. Conclusion. Splinted-OT and IOS-Omnicam are recommended for multi-unit implant impressions to enhance trueness, potentially benefiting subsequent manufacturing stages.

참고문헌 (46)

  1. Kan JY, "Clinical methods for evaluating implant framework fit", J Prosthet Dent, 81, pp.7~13 (1999)
  2. Sahin S, "The significance of passive framework fit in implant prosthodontics : current status", Implant Dent, 10, pp.85~92 (2001)
  3. Katsoulis J, "Misfit of implant prostheses and its impact on clinical outcomes. Definition, assessment and a systematic review of the literature", Eur J Oral Implantol, 10, pp.121~138 (2017)
  4. Richi MW, "Comparison of the accuracy of different impression procedures in case of multiple and angulated implants", Head Face Med, 16, pp.1~12 (2020)
  5. Klineberg IJ, "Design of superstructures for osseointegrated fixtures", Swed Dent J Suppl, 28, pp.63~69 (1985)
  6. Brånemark PI, "Osseointegration and its experimental background", J Prosthet Dent, 50, pp.399~410 (1983)
  7. Jemt T, "Failures and complications in 391 consecutively inserted fixed prostheses supported by Brånemark implants in edentulous jaws : a study of treatment from the time of prosthesis placement to the first annual checkup", Int J Oral Maxillofac Implants, 6, pp.270~276 (1991)
  8. Abduo J, "Assessing the fit of implant fixed prostheses : a critical review", Int J Oral Maxillofac Implants, 25, pp.506~515 (2010)
  9. Conrad HJ, "Accuracy of two impression techniques with angulated implants", J Prosthet Dent, 97, pp.349~356 (2007)
  10. Lee H, "Effect of subgingival depth of implant placement on the dimensional accuracy of the implant impression : an in vitro study", J Prosthet Dent, 99, pp.107~113 (2008)
  11. Laohverapanich K, "Different implant subgingival depth affects the trueness and precision of the 3d dental implant position : a comparative in vitro study among five digital scanners and a conventional technique", Int J Oral Maxillofac Implants, 36, pp.1111~1120 (2021)
  12. Assuncao WG, "Evaluation of transfer impressions for osseointegrated implants at various angulations", Implant Dent, 13, pp.358~366 (2004)
  13. Lee H, "The accuracy of implant impressions : a systematic review", J Prosthet Dent, 100, pp.285~291 (2008)
  14. Chia VA, "In vitro three-dimensional accuracy of digital implant impressions : the effect of implant angulation", Int J Oral Maxillofac Implants, 32, pp.313~321 (2017)
  15. Moreira AH, "Accuracy comparison of implant impression techniques : a systematic review", Clin Implant Dent Relat Res, 17(Suppl 2), pp.e751~64 (2015)
  16. Sanda M, "Trueness and precision of digital implant impressions by intraoral scanners : a literature review", Int J Implant Dent, 7, pp.1~25 (2021)
  17. Spitznagel F, "Prosthetic protocols in implant-based oral rehabilitations : A systematic review on the clinical outcome of monolithic all-ceramic single-and multi-unit prostheses", Eur J Oral Implant, 10, pp.89~99 (2017)
  18. Papaspyridakos P, "Digital vs conventional implant impressions : a systematic review and meta-analysis", J Prosthodont, 29, pp.660~678 (2020)
  19. Robles-Medina M, "Digital intraoral impression methods : an update on accuracy", Curr Oral Heal Rep, 7, pp.361~375 (2020)
  20. Gómez-Polo M, "Influence of the implant scan body bevel location, implant angulation and position on intraoral scanning accuracy: An in vitro study", J Dent, 121, pp.104122~ (2022)
  21. Revilla-León M, "Comparison of conventional, photogrammetry, and intraoral scanning accuracy of complete-arch implant impression procedures evaluated with a coordinate measuring machine", J Prosthet Dent, 125, pp.470~478 (2021)
  22. Rotar RN, "Scanning distance influence on the intraoral scanning accuracy-an in vitro study", Materials(Basel), 15, pp.3061~ (2022)
  23. Zhang YJ, "Influence of different factors on the accuracy of digital impressions of multiple implants : an in vitro study", Int J Oral Maxillofac Implants, 36, pp.442~449 (2021)
  24. Alikhasi M, "Digital Implant impression technique accuracy : a systematic review", Implant Dent, 26, pp.929~935 (2017)
  25. Marques S, "Digital impressions in implant dentistry : a literature review", Int J Environ Res Public Health, 18, pp.1020~ (2021)
  26. An H, "Effect of scanning speed, scanning pattern, and tip size on the accuracy of intraoral digital scans", J Prosthet Dent, S0022-3913(22), pp.00326~00322 (2022)
  27. Cortes ARG, "Factors affecting trueness of intraoral scans : an update", Appl Sci, 12, pp.6675~ (2022)
  28. Medina-Sotomayor P, "Accuracy of four digital scanners according to scanning strategy in complete-arch impressions", PLoS One, 13, pp.e0202916~ (2018)
  29. Passos L, "Impact of different scanning strategies on the accuracy of two current intraoral scanning systems in complete-arch impressions : an in vitro study", Int J Comput Dent, 22, pp.307~319 (2019)
  30. Gavounelis NA, "The effect of scanning strategy on intraoral scanner’s accuracy", Dent J(Basel), 10, pp.123~ (2022)
  31. Ji-won Anh, "A comparison of the precision of three-dimensional images acquired by 2 digital intraoral scanners: effects of tooth irregularity and scanning direction", 대한치과교정학회지, 46(1), pp.3~12 (2016), 대한치과교정학회
  32. Oh KC, "Effects of scanning strategy and scanner type on the accuracy of intraoral scans : a new approach for assessing the accuracy of scanned data", J Prosthodont, 29, pp.518~523 (2020)
  33. Basaki K, "Accuracy of digital vs conventional implant impression approach : a three-dimensional comparative in vitro analysis", Int J Oral Maxillofac Implants, 32, pp.792~799 (2017)
  34. Lin WS, "Effect of implant divergence on the accuracy of definitive casts created from traditional and digital implant-level impressions : an in vitro comparative study", Int J Oral Maxillofac Implants, 30, pp.102~109 (2015)
  35. Schmidt A, "A comparative clinical study on the transfer accuracy of conventional and digital implant impressions using a new reference key-based method", Clin Oral Implants Res, 32, pp.460~469 (2021)
  36. Andriessen FS, "Applicability and accuracy of an intraoral scanner for scanning multiple implants in edentulous mandibles : a pilot study", J Prosthet Dent, 111, pp.186~194 (2014)
  37. Tsagkalidis G, "Accuracy of 3 different impression techniques for internal connection angulated implants", J Prosthet Dent, 114, pp.517~523 (2015)
  38. Stimmelmayr M, "Evaluation of impression accuracy for a four-implant mandibular model--a digital approach", Clin Oral Investig, 16, pp.1137~1142 (2012)
  39. Kurtulmus-Yilmaz S, "Digital evaluation of the accuracy of impression techniques and materials in angulated implants", J Dent, 42, pp.1551~1559 (2014)
  40. Elshenawy EA, "Cast accuracy obtained from different impression techniques at different implant angulations(in vitro study)", Int J Implant Dent, 4, pp.9~ (2018)
  41. Alsharbaty MHM, "A clinical comparative study of 3-dimensional accuracy between digital and conventional implant impression techniques", J Prosthodont, 28, pp.e902~8 (2019)
  42. Kim KR, "Conventional open-tray impression versus intraoral digital scan for implant-level complete-arch impression", J Prosthet Dent, 122, pp.543~549 (2019)
  43. Abduo J, "Accuracy of digital impressions versus conventional impressions for 2 implants : an in vitro study evaluating the effect of implant angulation", Int J Implant Dent, 7, pp.75~ (2021)
  44. Alikhasi M, "Three-dimensional accuracy of digital impression versus conventional method : effect of implant angulation and connection type", Int J Dent, 2018, pp.3761750~ (2018)
  45. Lee JH, "Trueness of digital implant impressions based on implant angulation and scan body materials", Sci Rep, 11, pp.21892~ (2021)
  46. Sorrentino R, "Effect of implant angulation, connection length, and impression material on the dimensional accuracy of implant impressions: an in vitro comparative study", Clin Implant Dent Relat Res, 12(Suppl 1), pp.e63~76 (2010)

관련 논문AI추천

Comparison of 3D accuracy of three different digital intraoral scanners in full-arch implant impressionsFunda Bayindir, Ismail Hakki Korkmaz, Ozcan Akkal대한치과보철학회 · The Journal of Advanced of Prosthodontics2023 · 제15권 제4호Accuracy of digital and conventional dental implant impressions for fixed partial dentures: A comparative clinical studyAgne Gedrimiene, Rimas Adaskevicius, Vygandas Rutkunas대한치과보철학회 · The Journal of Advanced of Prosthodontics2019 · 제11권 제5호Effect of reference objects on the accuracy of digital implant impressions in partially edentulous archesAgnė Gedrimienė, Darius Jegelevičius, Justinas Pletkus, Liudas Auškalnis, Mutlu Özcan, Mykolas Akulauskas, Tan Fırat Eyüboğlu, Vygandas Rutkūnas대한치과보철학회 · The Journal of Advanced of Prosthodontics2024 · 제16권 제5호Comparison of accuracy between digital and conventional implant impressions: two and three dimensional evaluationsChuang Bi, Fangfang Tian, Jiaming Zhao, Xingyu Wang, Zhe Qu대한치과보철학회 · The Journal of Advanced of Prosthodontics2022 · 제14권 제4호Reverse engineering technique on the evaluation of impression accuracy in angulated implants박진홍, 송소연, 이기선, 이정열, 정홍택대한치과보철학회 · 대한치과보철학회지2021 · 제59권 제3호In vitro evaluation of the effect of auxiliary geometric device on measurement trueness and scanning time in fullarch implant impressionsEmine Begüm Büyükerkmen, Sema Ateşalp İleri대한치과보철학회 · The Journal of Advanced of Prosthodontics2025 · 제17권 제4호

이 간행물의 다른 논문 (4건)