본문 바로가기
KERD
논문KCI 등재

Fit analysis of implant-supported Co-Cr bars fabricated using casting, selective laser sintering, soft and dense milling techniques

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

PURPOSE. This in vitro study evaluated the fit of implant-supported bars fabricated using different computer-aided manufacturing (CAM) techniques. Materials and Methods. A mandibular model with four dental implants (Nobel Replace Conical Connection, 3.5 mm × 11.5 mm) was fabricated using photoelastic resin. Sixteen Co-Cr implant-supported bars were produced using four CAM techniques: casting milled wax (CMW), selective laser sintering (SLS), dense milling (DM), and soft milling (SM) (n = 4). Fit was assessed through photoelastic stress analysis and digital scanning with a topographic digitizer (BreuckmannSmartScan). A standardized coordinate system was used for fit analysis. Data were analyzed using the Kruskal-Wallis test, with Dunn-Bonferroni for multiple comparisons (α = .05). RESULTS. Photoelastic analysis showed that bars fabricated with DM exhibited the lowest stress levels, while SM showed moderate stress. Fit was significantly influenced by Δy-z, Δdin, and Δdout (P < .01), whereas Δhex and Δx-z had no significant effect (P > .05). The highest mean Δy-z value was observed in CMW (0.68 ± 0.28°) and the lowest in SLS (0.01 ± 0.34°). CMW had the highest Δdin (-160.44 ± 61.17 µm) and DM the lowest (-5.46 ± 11.80 µm). DM showed the highest Δdout (46.23 ± 39.32 µm), while SM had the lowest (-55.04 ± 35.06 µm), with significant differences among the techniques. CONCLUSION. In conclusion, full-arch implant supported Co-Cr bars fabricated using the different CAM techniques exhibited clinically acceptable passive fit. [J Adv Prosthodont 2025;17:210-23]

Abstract

PURPOSE. This in vitro study evaluated the fit of implant-supported bars fabricated using different computer-aided manufacturing (CAM) techniques. Materials and Methods. A mandibular model with four dental implants (Nobel Replace Conical Connection, 3.5 mm × 11.5 mm) was fabricated using photoelastic resin. Sixteen Co-Cr implant-supported bars were produced using four CAM techniques: casting milled wax (CMW), selective laser sintering (SLS), dense milling (DM), and soft milling (SM) (n = 4). Fit was assessed through photoelastic stress analysis and digital scanning with a topographic digitizer (BreuckmannSmartScan). A standardized coordinate system was used for fit analysis. Data were analyzed using the Kruskal-Wallis test, with Dunn-Bonferroni for multiple comparisons (α = .05). RESULTS. Photoelastic analysis showed that bars fabricated with DM exhibited the lowest stress levels, while SM showed moderate stress. Fit was significantly influenced by Δy-z, Δdin, and Δdout (P < .01), whereas Δhex and Δx-z had no significant effect (P > .05). The highest mean Δy-z value was observed in CMW (0.68 ± 0.28°) and the lowest in SLS (0.01 ± 0.34°). CMW had the highest Δdin (-160.44 ± 61.17 µm) and DM the lowest (-5.46 ± 11.80 µm). DM showed the highest Δdout (46.23 ± 39.32 µm), while SM had the lowest (-55.04 ± 35.06 µm), with significant differences among the techniques. CONCLUSION. In conclusion, full-arch implant supported Co-Cr bars fabricated using the different CAM techniques exhibited clinically acceptable passive fit. [J Adv Prosthodont 2025;17:210-23]

관련 논문AI추천

Role of span length in the adaptation of implant-supported cobalt chromium frameworks fabricated by three techniquesHuang Yiqing, Li Yong, Ma Xiao, Wang Jiawei, Zhou Ying대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제2호Effect of repetitive firing on passive fit of metal substructure produced by the laser sintering in implantsupported fixed prosthesisHakan Akin, Musa Aykut Altintas대한치과보철학회 · The Journal of Advanced of Prosthodontics2020 · 제12권 제3호Precision of the milled full-arch framework fabricated using presintered soft alloy: A pilot study이규복, 이두형, 이청희, 조성암, 조진현, Hyun-Wook Woo대한치과보철학회 · The Journal of Advanced of Prosthodontics2018 · 제10권 제2호Biomechanical behavior of CAD/CAM cobalt-chromium and zirconia full-arch fixed prosthesesAnna Gabriella Camacho Presotto, Daniele Valente Velôso, Francisco Carlos Groppo, Guilherme Almeida Borges, Letícia Del Rio Silva, Marcelo Ferraz Mesquita, Thaís Barbin, Valentim Adelino Ricardo Barão대한치과보철학회 · The Journal of Advanced of Prosthodontics2020 · 제12권 제6호Three-dimensional accuracy of different correction methods for cast implant bars권지영, 권호범, 김명주, 김창회, 임영준대한치과보철학회 · The Journal of Advanced of Prosthodontics2014 · 제6권 제1호Prosthetic misfit of implant-supported prosthesis obtained by an alternative section methodFa′bio Afra∧nio de Aguiar Ju′nior, Hilmo Barreto Leite Falcão-Filho, Maria da Gloria Chiarello de Mattos, Renata Cristina Silveira Rodrigues, Ricardo Faria Ribeiro, Rodrigo Tiossi대한치과보철학회 · The Journal of Advanced of Prosthodontics2012 · 제4권 제2호

이 간행물의 다른 논문 (5건)