본문 바로가기
KERD
논문KCI 등재

Progress in Automated Urinalysis

1

조회

0

다운로드

8

인용

0

참고문헌

주제분류병리학

초록

New technological advances have paved the way for significant progress in automated urinalysis. Quantitative reading of urinary test strips using reflectometry has become possible, while complementary metal oxide semiconductor (CMOS) technology has enhanced analytical sensitivity and shown promise in microalbuminuria testing. Microscopy-based urine particle analysis has greatly progressed over the past decades, enabling high throughput in clinical laboratories. Urinary flow cytometry is an alternative for automated microscopy, and more thorough analysis of flow cytometric data has enabled rapid differentiation of urinary microorganisms. Integration of dilution parameters (e.g., creatinine, specific gravity, and conductivity) in urine test strip readers and urine particle flow cytometers enables correction for urinary dilution, which improves result interpretation. Automated urinalysis can be used for urinary tract screening and for diagnosing and monitoring a broad variety of nephrological and urological conditions; newer applications show promising

Abstract

New technological advances have paved the way for significant progress in automated urinalysis. Quantitative reading of urinary test strips using reflectometry has become possible, while complementary metal oxide semiconductor (CMOS) technology has enhanced analytical sensitivity and shown promise in microalbuminuria testing. Microscopy-based urine particle analysis has greatly progressed over the past decades, enabling high throughput in clinical laboratories. Urinary flow cytometry is an alternative for automated microscopy, and more thorough analysis of flow cytometric data has enabled rapid differentiation of urinary microorganisms. Integration of dilution parameters (e.g., creatinine, specific gravity, and conductivity) in urine test strip readers and urine particle flow cytometers enables correction for urinary dilution, which improves result interpretation. Automated urinalysis can be used for urinary tract screening and for diagnosing and monitoring a broad variety of nephrological and urological conditions; newer applications show promising

참고문헌 (83)

  1. Hannemann-Pohl K, "Automation of urine sediment examination : a comparison of the Sysmex UF-100 automated flow cytometer with routine manual diagnosis(microscopy, test strips, and bacterial culture)", Clin Chem Lab Med, 37, pp.753~764 (1999)
  2. Fogazzi GB, "The different ways to obtain digital images of urine microscopy findings : their advantages and limitations", Clin Chim Acta, 466, pp.160~161 (2017)
  3. Langlois MR, "Automated flow cytometry compared with an automated dipstick reader for urinalysis", Clin Chem, 45, pp.118~122 (1999)
  4. Penders J, "Quantitative evaluation of urinalysis test strips", Clin Chem, 48, pp.2236~2241 (2002)
  5. Kubelka P, "A contribution to the optics of paints", Z Tech Phys, 12, pp.593~601 (1931)
  6. Penders J, "Quantitative measurement of ketone bodies in urine using reflectometry", Clin Chem Lab Med, 43, pp.724~729 (2005)
  7. Decavele AS, "A sensitive quantitative test strip based point-of-care albuminuria screening assay", Clin Chem Lab Med, 50, pp.673~678 (2012)
  8. Delanghe JR, "Sensitive albuminuria analysis using dye-binding based test strips", Clin Chim Acta, 471, pp.107~112 (2017)
  9. Guy M, "Diagnostic accuracy of the urinary albumin : creatinine ratio determined by the CLINITEK Microalbumin and DCA 2000+ for the rule-out of albuminuria in chronic kidney disease", Clin Chim Acta, 399, pp.54~58 (2009)
  10. Oyaert MN, "Quantitative urine test strip reading for leukocyte esterase and hemoglobin peroxidase", Clin Chem Lab Med, 56, pp.1126~1132 (2018)
  11. "Urit 14F urine reagent strips. Package insert", Urit medical Electronic Co., Ltd, ~
  12. Smith GT, "Robust dipstick urinalysis using a low-cost, micro-volume slipping manifold and mobile phone platform", Lab Chip, 16, pp.2069~2078 (2016)
  13. Lee DS, "A simple and smart telemedicine device for developing regions : a pocket-sized colorimetric reader", Lab Chip, 11, pp.120~126 (2011)
  14. Mohammadi S, "An instrument-free, screen-printed paper microfluidic device that enables bio and chemical sensing", Analyst, 140, pp.6493~6499 (2015)
  15. Ginardi RVH, "Intelligent method for dipstick urinalysis using smartphone camera", Information and communication technology. ICT-EurAsia 2014. Lecture notes in computer science, 8407, pp.66~77 (2014), Springer
  16. İnce FD, "The comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysis", Pract Lab Med, 5, pp.14~20 (2016)
  17. Chien TI, "Urine sediment examination : a comparison of automated urinalysis systems and manual microscopy", Clin Chim Acta, 384, pp.28~34 (2007)
  18. Linko S, "Analytical performance of the Iris iQ200 automated urine microscopy analyzer", Clin Chim Acta, 372, pp.54~64 (2006)
  19. Wah DT, "Analytic performance of the iQ200 automated urine microscopy analyzer and comparison with manual counts using Fuchs-Rosenthal cell chambers", Am J Clin Pathol, 123, pp.290~296 (2005)
  20. 박주원, "자동 요침사분석기 iQ200의 평가", Annals of Laboratory Medicine, 28(4), pp.267~273 (2008), 대한진단검사의학회
  21. Budak YU, "Comparison of three automated systems for urine chemistry and sediment analysis in routine laboratory practice", Clin Lab, 57, pp.47~52 (2011)
  22. Shayanfar N, "Automated urinalysis : first experiences and a comparison between the Iris iQ200 urine microscopy system, the Sysmex UF-100 flow cytometer and manual microscopic particle counting", Clin Chem Lab Med, 45, pp.1251~1256 (2007)
  23. Stürenburg E, "Detection of significant bacteriuria by use of the iQ200 automated urine microscope", J Clin Microbiol, 52, pp.2855~2860 (2014)
  24. Lamchiagdhase P, "Urine sediment examination : a comparison between the manual method and the iQ200 automated urine microscopy analyzer", Clin Chim Acta, 358, pp.167~174 (2005)
  25. Anderlini R, "Automated urinalysis with expert review for incidental identification of atypical urothelial cells : an anticipated bladder carcinoma diagnosis", Clin Chim Acta, 451, pp.252~256 (2015)
  26. Yüksel H, "Comparison of fully automated urine sediment analyzers H800-FUS100 and LabUMat-UriSed with manual microscopy", J Clin Lab Anal, 27, pp.312~316 (2013)
  27. Kocer D, "Cutoff values for bacteria and leukocytes for urine sediment analyzer FUS200 in culture-positive urinary-tract infections", Scand J Clin Lab Invest, 74, pp.414~417 (2014)
  28. Dewulf G, "Evaluation of the performances of the iQ(®)200 ELITE automated urine microscopy analyser and comparison with manual microscopy method", Pathol Biol(Paris), 59, pp.264~268 (2011)
  29. Akın OK, "Comparison of LabUMat-with-urised and iQ200 fully automatic urine sediment analysers with manual urine analysis", Biotechnol Appl Biochem, 53, pp.139~144 (2009)
  30. Zaman Z, "Urine sediment analysis : analytical and diagnostic performance of sediMAX – a new automated microscopy image-based urine sediment analyser", Clin Chim Acta, 411, pp.147~154 (2010)
  31. Castiglione V, "Distinction between urine crystals by automated urine analyzer SediMAX conTRUST is specific but lacks sensitivity", Clin Chem Lab Med, 55, pp.e288~e290 (2017)
  32. Intra J, "Improvement in the detection of enteric protozoa from clinical stool samples using the automated urine sediment analyzer sediMAX® 2 compared to sediMAX® 1", Eur J Clin Microbiol Infect Dis, 36, pp.147~151 (2017)
  33. Lee W, "Comparison of the automated cobas u 701 urine microscopy and UF-1000i flow cytometry systems and manual microscopy in the examination of urine sediments", J Clin Lab Anal, 30, pp.663~671 (2016)
  34. Wesarachkitti B, "Performance evaluation and comparison of the fully automated urinalysis analyzers UX-2000 and Cobas", Lab Med, 47, pp.124~133 (2016)
  35. Bakan E, "Comparison of Cobas 6500 and Iris IQ200 fully-automated urine analyzers to manual urine microscopy", Biochem Med(Zagreb), 26, pp.365~375 (2016)
  36. Delanghe JR, "The role of automated urine particle flow cytometry in clinical practice", Clin Chim Acta, 301, pp.1~18 (2000)
  37. Manoni F, "Urine particle evaluation : a comparison between the UF-1000i and quantitative microscopy", Clin Chem Lab Med, 48, pp.1107~1111 (2010)
  38. Jiang T, "Urine particles analysis : performance evaluation of Sysmex UF-1000i and comparison among urine flow cytometer, dipstick, and visual microscopic examination", Scand J Clin Lab Invest, 71, pp.30~37 (2011)
  39. Previtali G, "Performance evaluation of the new fully automated urine particle analyser UF-5000 compared to the reference method of the Fuchs-Rosenthal chamber", Clin Chim Acta, 472, pp.123~130 (2017)
  40. Sánchez-Mora C, "Comparison of automated devices UX-2000 and SediMAX", AutionMax for urine samples screening : a multicenter Spanish study, 2017, pp.50, 714~718
  41. Gessoni G, "Does flow cytometry have a role in preliminary differentiation between urinary tract infections sustained by gram positive and gram negative bacteria? An Italian polycentric study", Clin Chim Acta, 440, pp.152~156 (2015)
  42. De Rosa R, "Evaluation of the Sysmex UF1000i flow cytometer for ruling out bacterial urinary tract infection", Clin Chim Acta, 411, pp.1137~1142 (2010)
  43. Oyaert M, "Laboratory diagnosis of urinary tract infections : towards a BILULU consensus guideline", J Microbiol Methods, 146, pp.92~99 (2018)
  44. Broeren MA, "Screening for urinary tract infection with the Sysmex UF-1000i urine flow cytometer", J Clin Microbiol, 49, pp.1025~1029 (2011)
  45. Jolkkonen S, "Screening of urine samples by flow cytometry reduces the need for culture", J Clin Microbiol, 48, pp.3117~3121 (2010)
  46. Mejuto P, "Automated flow cytometry : an alternative to urine culture in a routine clinical microbiology laboratory", Int J Microbiol, 2017, pp.8532736~ (2017)
  47. Yusuf E, "Performance of urinalysis tests and their ability in predicting results of urine cultures : a comparison between automated test strip analyser and flow cytometry in various subpopulations and types of samples", J Clin Pathol, 70, pp.631~636 (2017)
  48. Monsen T, "A new concept and a comprehensive evaluation of SYSMEX UF-1000i flow cytometer to identify culture-negative urine specimens in patients with UTI", Eur J Clin Microbiol Infect Dis, 36, pp.1691~1703 (2017)[DOI]
  49. García-Coca M, "Relationship between conventional culture and flow cytometry for the diagnosis of urinary tract infection", J Microbiol Methods, 137, pp.14~18 (2017)
  50. Íñigo M, "Evaluation of the SediMax automated microscopy sediment analyzer and the Sysmex UF-1000i flow cytometer as screening tools to rule out negative urinary tract infections", Clin Chim Acta, 456, pp.31~35 (2016)
  51. Martín-Gutiérrez G, "Evaluation and optimization of the Sysmex UF1000i system for the screening of urinary tract infection in primary health care elderly patients", Enferm Infecc Microbiol Clin, 33, pp.320~323 (2015)
  52. Gutiérrez-Fernández J, "Performance of the Sysmex UF1000i system in screening for significant bacteriuria before quantitative culture of aerobic", facultative fast-growth bacteria in a reference hospital, 2012, pp.113, 609~614
  53. Kadkhoda K, "UF-1000i flow cytometry is an effective screening method for urine specimens", Diagn Microbiol Infect Dis, 69, pp.130~136 (2011)
  54. Pieretti B, "Diagnosis of bacteriuria and leukocyturia by automated flow cytometry compared with urine culture", J Clin Microbiol, 48, pp.3990~3996 (2010)
  55. van der Zwet WC, "Evaluation of the Sysmex UF-1000i® urine flow cytometer in the diagnostic work-up of suspected urinary tract infection in a Dutch general hospital", Clin Chem Lab Med, 48, pp.1765~1771 (2010)
  56. Krongvorakul J, "A flow cytometric urine analyzer for bacteria and white blood cell counts plus urine dispstick test for rapid screening of bacterial urinary tract infection", Asian Biomed, 6, pp.601~608 (2012)
  57. Poropatich CO, "Inconsistent detection of bacteriuria with the Yellow IRIS automated urinalysis workstation", Lab Med, 19, pp.499~501 (1988)
  58. McCrossin T, "Comparison of hydrometry, refractometry, osmometry and Ames N-Multistix SG in estimation of urinary concentration", Aust Paediatr J, 21, pp.185~188 (1985)
  59. Brandon CA, "Urine specific gravity measurement : reagent strip versus refractometer", Clin Lab Sci, 7, pp.308~310 (1994)
  60. Dorizzi RM, "Measurement of urine relative density using refractometer and reagent strips", Clin Chem Lab Med, 36, pp.925~928 (1998)
  61. Íñigo M, "Direct identification of urinary tract pathogens from urine samples, combining urine screening methods and matrix-assisted laser desorption ionization-time of flight mass spectrometry", J Clin Microbiol, 54, pp.988~993 (2016)
  62. Zboromyrska Y, "Development of a new protocol for rapid bacterial identification and susceptibility testing directly from urine samples", Clin Microbiol Infect, 22, pp.561.e1~561.e6 (2016)[DOI]
  63. Veron L, "Rapid urine preparation prior to identification of uropathogens by MALDI-TOF MS", Eur J Clin Microbiol Infect Dis, 34, pp.1787~1795 (2015)
  64. Ferreira L, "Direct identification of urinary tract pathogens from urine samples by matrix-assisted laser desorption ionization-time of flight mass spectrometry", J Clin Microbiol, 48, pp.2110~2115 (2010)
  65. Stevenson LG, "Evaluation of matrix-assisted laser desorption ionization-time of flight mass spectrometry for identification of clinically important yeast species", J Clin Microbiol, 48, pp.3482~3486 (2010)
  66. Wang XH, "Direct identification of bacteria causing urinary tract infections by combining matrix-assisted laser desorption ionization-time of flight mass spectrometry with UF-1000i urine flow cytometry", J Microbiol Methods, 92, pp.231~235 (2013)
  67. March Rosselló GA, "Procedure for microbial identification based on matrix-assisted laser desorption", ionization-time of flight mass spectrometry from screening-positive urine samples, 2014, pp.122, 790~795
  68. Demarco ML, "Diafiltration MALDI-TOF mass spectrometry method for culture-independent detection and identification of pathogens directly from urine specimens", Am J Clin Pathol, 141, pp.204~212 (2014)
  69. Seng P, "Ongoing revolution in bacteriology : routine identification of bacteria by matrix-assisted laser desorption ionization time-of-flight mass spectrometry", Clin Infect Dis, 49, pp.543~551 (2009)
  70. Burillo A, "Gram-stain plus MALDI-TOF MS(matrix-assisted laser desorption ionization-time of flight mass spectrometry)for a rapid diagnosis of urinary tract infection", PLoS One, 9, pp.e86915~ (2014)
  71. Köhling HL, "Direct identification of bacteria in urine samples by matrix-assisted laser desorption", ionization time-of-flight mass spectrometry and relevance of defensins as interfering factors, 2012, pp.61, 339~344
  72. Singhal N, "MALDI-TOF mass spectrometry : an emerging technology for microbial identification and diagnosis", Front Microbiol, 6, pp.791~ (2015)
  73. Kline KA, "Gram-positive uropathogens, polymicrobial urinary tract infection, and the emerging microbiota of the urinary tract", Microbiol Spectr, 4 (2016)
  74. Siegman-Igra Y, "The significance of urine culture with mixed flora", Curr Opin Nephrol Hypertens, 3, pp.656~659 (1994)
  75. Jung JS, "Rapid detection of antibiotic resistance based on mass spectrometry and stable isotopes", Eur J Clin Microbiol Infect Dis, 33, pp.949~955 (2014)
  76. Oviaño M, "Rapid direct detection of carbapenemase-producing Enterobacteriaceae in clinical urine samples by MALDI-TOF MS analysis", J Antimicrob Chemother, 72, pp.1350~1354 (2017)
  77. Lee DS, "A simple and smart telemedicine device for developing regions : a pocket-sized colorimetric reader", Lab Chip, 11, pp.120~126 (2011)
  78. Yetisen AK, "Paper-based microfluidic point-of-care diagnostic devices", Lab Chip, 13, pp.2210~2251 (2013)
  79. Jalal UM, "Paper-plastic hybrid microfluidic device for smartphone-based colorimetric analysis of urine", Anal Chem, 89, pp.13160~13166 (2017)
  80. Hosseini SA, "Microfluidic device for label-free quantitation and distinction of bladder cancer cells from the blood cells using micro machined silicon based electrical approach; suitable in urinalysis assays", J Pharm Biomed Anal, 134, pp.36~42 (2017)
  81. Cho S, "Smartphone-based, sensitive μPAD detection of urinary tract infection and gonorrhea", Biosens Bioelectron, 74, pp.601~611 (2015)
  82. Kouri TT, "Towards European urinalysis guidelines. Introduction of a project under European Confederation of Laboratory Medicine", Clin Chim Acta, 297, pp.305~311 (2000)
  83. Delanghe JR, "Preanalytics in urinalysis", Clin Biochem, 49, pp.1346~1350 (2016)

관련 논문AI추천

이 간행물의 다른 논문 (18건)