Evaluation of Five Automated Urine Analyzers as Screening Instruments for Enhancing Diagnostic Efficiency in Urinary Tract Infection

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Background: Although urine culture is considered a reference standard for the diagnosis ofurinary tract infection (UTI), it is time-consuming, labor-intensive, and expensive. Here, weevaluated the performance of five recent automated urine analyzers for UTI diagnosis. Methods: For the 510 specimens analyzed, the criterion for ‘significant bacteriuria’ wasdefined as ≥ 104 CFU/mL in the inoculated plate for all specimens or ≥ 103 CFU/mL forspecimens from patients using a Foley catheter or with urinary symptoms. Sensitivity,specificity, positive predictive value (PPV), and negative predictive value (NPV) of UTI wereanalyzed using indicators individually, in different combinations, or with various cut-offvalues. Results: Seventy-one specimens (13.9%) exhibited ‘significant bacteriuria’. In the receiveroperating characteristics curve analysis, UF-5000 (Sysmex Corp., Japan) showed the highestarea under the curve values for both males and females (0.876 and 0.846, respectively). The PPVs for specimens from males with all indicators positive increased up to 100% afteradjusting the cut-off values. NPVs for specimens with all indicators negative were 94.3%–98.2% in males and 78.1%–93.8% in females after adjusting the cut-off values. Conclusion: As a rapid and accurate diagnostic tool, urine sediment analyzers can bevaluable for UTI diagnosis by reducing unnecessary culture and can help cliniciansdetermine a treatment plan.

Abstract

Background: Although urine culture is considered a reference standard for the diagnosis ofurinary tract infection (UTI), it is time-consuming, labor-intensive, and expensive. Here, weevaluated the performance of five recent automated urine analyzers for UTI diagnosis. Methods: For the 510 specimens analyzed, the criterion for ‘significant bacteriuria’ wasdefined as ≥ 104 CFU/mL in the inoculated plate for all specimens or ≥ 103 CFU/mL forspecimens from patients using a Foley catheter or with urinary symptoms. Sensitivity,specificity, positive predictive value (PPV), and negative predictive value (NPV) of UTI wereanalyzed using indicators individually, in different combinations, or with various cut-offvalues. Results: Seventy-one specimens (13.9%) exhibited ‘significant bacteriuria’. In the receiveroperating characteristics curve analysis, UF-5000 (Sysmex Corp., Japan) showed the highestarea under the curve values for both males and females (0.876 and 0.846, respectively). The PPVs for specimens from males with all indicators positive increased up to 100% afteradjusting the cut-off values. NPVs for specimens with all indicators negative were 94.3%–98.2% in males and 78.1%–93.8% in females after adjusting the cut-off values. Conclusion: As a rapid and accurate diagnostic tool, urine sediment analyzers can bevaluable for UTI diagnosis by reducing unnecessary culture and can help cliniciansdetermine a treatment plan.

참고문헌 (25)

  1. Broeren MA, "Screening for urinary tract infection with the Sysmex UF-1000i urine flow cytometer", J Clin Microbiol, 49, pp.1025~1029 (2011)
  2. Jolkkonen S, "Screening of urine samples by flow cytometry reduces the need for culture", J Clin Microbiol, 48, pp.3117~3121 (2010)
  3. Manoni F, "Cutoff values for bacteria and leukocytes for urine flow cytometer Sysmex UF-1000i in urinary tract infections", Diagn Microbiol Infect Dis, 65, pp.103~107 (2009)
  4. Kritsotakis EI, "Prevalence, incidence burden, and clinical impact of healthcare-associated infections and antimicrobial resistance: a national prevalent cohort study in acute care hospitals in Greece", Infect Drug Resist, 10, pp.317~328 (2017)
  5. Umscheid CA, "Estimating the proportion of healthcare-associated infections that are reasonably preventable and the related mortality and costs", Infect Control Hosp Epidemiol, 32, pp.101~114 (2011)
  6. Shang YJ, "Systematic review and meta-analysis of flow cytometry in urinary tract infection screening", Clin Chim Acta, 424, pp.90~95 (2013)
  7. Tessari A, "Screening of presumptive urinary tract infections by the automated urine sediment analyser sediMAX", Clin Chem Lab Med, 53, pp.S1503~8 (2015)
  8. Pieretti B, "Diagnosis of bacteriuria and leukocyturia by automated flow cytometry compared with urine culture", J Clin Microbiol, 48, pp.3990~3996 (2010)
  9. Kim SY, "Evaluation of the Sysmex UF-100 urine cell analyzer as a screening test to reduce the need for urine cultures for communityacquired urinary tract infection", Am J Clin Pathol, 128, pp.922~925 (2007)
  10. Parta M, "IRIS iQ200 workstation as a screen for performing urine culture", Diagn Microbiol Infect Dis, 75, pp.5~8 (2013)
  11. Russcher A, "Interlaboratory collaboration for optimized screening for urinary tract infection", J Clin Microbiol, 54, pp.93~98 (2016)
  12. Gupta K, "Increasing antimicrobial resistance and the management of uncomplicated community-acquired urinary tract infections", Ann Intern Med, 135, pp.41~50 (2001)
  13. García-Coca M, "Relationship between conventional culture and flow cytometry for the diagnosis of urinary tract infection", J Microbiol Methods, 137, pp.14~18 (2017)
  14. Gutiérrez-Fernández J, "Performance of the Sysmex UF 1000i system in screening for significant bacteriuria before quantitative culture of aerobic", facultative fast-growth bacteria in a reference hospital, 2012, pp.113, 609~614
  15. Íñigo M, "Evaluation of the SediMax automated microscopy sediment analyzer and the Sysmex UF-1000i flow cytometer as screening tools to rule out negative urinary tract infections", Clin Chim Acta, 456, pp.31~35 (2016)
  16. Chan WW, "Clinical microbiology procedures handbook", pp.1~33 (2016), ASM Press
  17. Stürenburg E, "Detection of significant bacteriuria by use of the iQ200 automated urine microscope", J Clin Microbiol, 52, pp.2855~2860 (2014)
  18. Victoria Ortiz de la Tabla,, "Performance of the cobas u 701 Analyzer in Urinary Tract Infection Screening", Annals of Laboratory Medicine, 39(5), pp.464~469 (2019), 대한진단검사의학회[DOI]
  19. Aspevall O, "European guidelines for urinalysis : a collaborative document produced by European clinical microbiologists and clinical chemists under ECLM in collaboration with ESCMID", Clin Microbiol Infect, 7, pp.173~178 (2001)
  20. Stamm WE, "Measurement of pyuria and its relation to bacteriuria", Am J Med, 75, pp.53~58 (1983)
  21. Kadkhoda K, "UF-1000i™flow cytometry is an effective screening method for urine specimens", Diagn Microbiol Infect Dis, 69, pp.130~136 (2011)
  22. Wang J, "Evaluation of the Sysmex UF-1000i for the diagnosis of urinary tract infection", Am J Clin Pathol, 133, pp.577~582 (2010)
  23. Marschal M, "Evaluation of 3 different rapid automated systems for diagnosis of urinary tract infections", Diagn Microbiol Infect Dis, 72, pp.125~130 (2012)
  24. Previtali G, "Performance evaluation of the new fully automated urine particle analyser UF-5000 compared to the reference method of the Fuchs-Rosenthal chamber", Clin Chim Acta, 472, pp.123~130 (2017)
  25. De Rosa R, "Evaluation of the new Sysmex UF-5000 fluorescence flow cytometry analyser for ruling out bacterial urinary tract infection and for prediction of Gram negative bacteria in urine cultures", Clin Chim Acta, 484, pp.171~178 (2018)

관련 논문AI추천

이 간행물의 다른 논문 (4건)