Reliability of the DI-60 Digital Image Analyzer for Detecting Platelet Clumping and Obtaining Accurate Platelet Counts

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류병리학

초록

Pseudothrombocytopenia caused by platelet clumping (PC) can lead to unnecessary platelet transfusions or underdiagnosis of hematologic neoplasms. To overcome these limitations, we assessed the capacity of the Sysmex DI-60 digital morphology analyzer (Sysmex, Kobe, Japan) for detecting PC and determining an accurate platelet count in the presence of PC. For this purpose, 135 samples with or without PC (groups Y and N, respectively) were processed by an examiner (a hematologic specialist) using both the Sysmex XN-9000 and DI-60 analyzers. Although the platelet aggregate (PA) and giant platelet (GP) counts reported by the DI-60 and the examiner exhibited strong correlations, they proved inadequate as effective indicators for screening samples containing PC. Between the PA and GP counts and four platelet indices (the platelet distribution width [PDW], mean platelet volume [MPV], platelet large cell ratio [P_LCR], and plateletcrit [PCT]) reported by the XN- 9000, we observed statistically significant correlations (both overall and with group Y), but they were relatively weak. The platelet counts determined using the DI-60 and light microscopy in group Y showed substantial variations. Although the performance of the DI-60 was reliable for detecting PA and GP in smear images, such fixed areas are not representative of whole samples. Further, in the presence of PC, the resulting platelet counts determined using the DI-60 were not sufficiently accurate to be accepted as the final count.

Abstract

Pseudothrombocytopenia caused by platelet clumping (PC) can lead to unnecessary platelet transfusions or underdiagnosis of hematologic neoplasms. To overcome these limitations, we assessed the capacity of the Sysmex DI-60 digital morphology analyzer (Sysmex, Kobe, Japan) for detecting PC and determining an accurate platelet count in the presence of PC. For this purpose, 135 samples with or without PC (groups Y and N, respectively) were processed by an examiner (a hematologic specialist) using both the Sysmex XN-9000 and DI-60 analyzers. Although the platelet aggregate (PA) and giant platelet (GP) counts reported by the DI-60 and the examiner exhibited strong correlations, they proved inadequate as effective indicators for screening samples containing PC. Between the PA and GP counts and four platelet indices (the platelet distribution width [PDW], mean platelet volume [MPV], platelet large cell ratio [P_LCR], and plateletcrit [PCT]) reported by the XN- 9000, we observed statistically significant correlations (both overall and with group Y), but they were relatively weak. The platelet counts determined using the DI-60 and light microscopy in group Y showed substantial variations. Although the performance of the DI-60 was reliable for detecting PA and GP in smear images, such fixed areas are not representative of whole samples. Further, in the presence of PC, the resulting platelet counts determined using the DI-60 were not sufficiently accurate to be accepted as the final count.

참고문헌 (14)

  1. Lardinois B, "Pseudothrombocytopenia—a review on causes, occurrence and clinical implications", J Clin Med, 10, pp.594~ (2021)
  2. Baccini V, "Platelet counting: ugly traps and good advice. Proposals from the French-speaking Cellular Hematology Group (GFHC)", J Clin Med, 9, pp.808~ (2020)
  3. Bizzaro N, "EDTA-dependent pseudothrombocytopenia: a clinical and epidemiological study of 112 cases, with 10-year follow-up", Am J Hematol, 50, pp.103~109 (1995)
  4. Choe WH, "Pseudothrombocytopenia or platelet clumping as a possible cause of low platelet count in patients with viral infection : a case series from single institution focusing on hepatitis A virus infection", Int J Lab Hematol, 35, pp.70~76 (2013)
  5. Kratz A, "Digital morphology analyzers in hematology : ICSH review and recommendations", Int J Lab Hematol, 41, pp.437~447 (2019)
  6. Billard M, "Evaluation of the CellaVision DM automated microscope in pediatrics", Int J Lab Hematol, 32, pp.530~538 (2010)
  7. Gulati G, "Detection of platelet clumps on peripheral blood smears by CellaVision DM96 system and microscopic review", Lab Med, 45, pp.368~371 (2014)
  8. Gao Y, "Platelet count estimation using the CellaVision DM96 system", J Pathol Inform, 4, pp.16~ (2013)
  9. Gulati G, "Blood cells: morphology and clinical relevance" (2014), American Society for Clinical Pathology
  10. Mannuß S, "Influence of different methods and anticoagulants on platelet parameter measurement", J Lab Med, 44, pp.255~272 (2020)
  11. Nam M, "Digital Morphology Analyzer Sysmex DI-60 vs. Manual Counting for White Blood Cell Differentials in Leukopenic Samples: A Comparative Assessment of Risk and Turnaround Time", Ann Lab Med, 42, pp.398~405 (2022)
  12. Kim HN, "Performance of automated digital cell imaging analyzer Sysmex DI-60", Clin Chem Lab Med, 56, pp.94~102 (2017)
  13. Briggs C, "Continuing developments with the automated platelet count", Int J Lab Hematol, 29, pp.77~91 (2007)
  14. ICSH, "Platelet counting by the RBC", platelet ratio method : A reference method, 2001, pp.115, 460~464

관련 논문AI추천

Integration of an MC-80 Digital Image Analyzer With an Automated BC-6800Plus Hematology Analyzer Enables Accurate Platelet Counting in Samples With EDTA-Induced Pseudothrombocytopenia허정원, Kim Seunghwan, Park Sholhui, So Min-Kyung대한진단검사의학회 · Annals of Laboratory Medicine2024 · 제44권 제6호Maintenance of Platelet Counts with Low Level QC Materials and the Change in P-LCR according to Hemolysis with XN-9000심문정, Hyun-A Lee대한임상검사과학회 · 대한임상검사과학회지2018 · 제50권 제4호Digital Morphology Analyzer Sysmex DI-60 vs. Manual Counting for White Blood Cell Differentials in Leukopenic Samples: A Comparative Assessment of Risk and Turnaround TimeHur Mina, Kim Hanah, Kim Hyeong Nyeon, Lee Gun Hyuk, Nam Minjeong, Park Mikyoung, Yoon Sumi대한진단검사의학회 · Annals of Laboratory Medicine2022 · 제42권 제4호The Sysmex XN-2000 Hematology Autoanalyzer Provides a Highly Accurate Platelet Count than the Former Sysmex XE-2100 System Based on Comparison with the CD41/CD61 Immunoplatelet Reference Method of Flow Cytometry김미정, 박상혁, 박찬정, 이보라, 장성수, 조영욱, 한민영대한진단검사의학회 · Annals of Laboratory Medicine2014 · 제34권 제6호Unreliable Automated Complete Blood Count Results: Causes, Recognition, and ResolutionGong Jerald, Gulati Gene, Uppal Guldeep대한진단검사의학회 · Annals of Laboratory Medicine2022 · 제42권 제5호혈소판응집에 의한 위혈소판감소증의 검사실적 교정조덕, 기승정, 서순팔, 신명근, 신종희, 양동욱, 오봉준대한진단검사의학회 · Annals of Laboratory Medicine2005 · 제25권 제6호

이 간행물의 다른 논문 (25건)