In Korea, man-caused forest fires are known originate primarily in coniferous forests. We have hypothesized that the vulnerability of Pinus densiflora forests is principally a consequence of the ignition characteristics of the species. To assess this hypothesis, we conducted two combustion experiments using fallen leaves with a reference species, Quercus variabilis. In the first experiments, in which a cigarette was employed as a primary heat source for the initiation of a forest fire, the Pinus leaves caught fire significantly faster (1´1˝ at Pinus, 1´31˝ at Quercus, P < 0.001), and ignition proceeded normally. Quercus leaves, on the other hand, caught fire but did not ignite successfully. In the second set of experiments utilizing different moisture contents and fuel loads, the maximum flame temperature of the Pinus leaves was significantly higher (421°C at Pinus, 361°C at Quercus, P < 0.001) and the combustion persisted for longer than in the Quercus leaves (8´8˝ at Pinus, 3´38˝ at Quercus, P < 0.001). The moisture contents of the leaves appeared to be a more important factor in the maximum temperature achieved, whereas the most important factor in burning time was the amount of fuel. Overall, these results support the assumption that Pinus leaves can be ignited even by low-heat sources such as cigarettes. Additionally, once ignited, Pinus leaves burn at a relatively high flame temperature and burn for a prolonged period, thus raising the possibility of frequent fire occurrences and spread into crown fires in forests of P. densiflora.

Abstract

In Korea, man-caused forest fires are known originate primarily in coniferous forests. We have hypothesized that the vulnerability of Pinus densiflora forests is principally a consequence of the ignition characteristics of the species. To assess this hypothesis, we conducted two combustion experiments using fallen leaves with a reference species, Quercus variabilis. In the first experiments, in which a cigarette was employed as a primary heat source for the initiation of a forest fire, the Pinus leaves caught fire significantly faster (1´1˝ at Pinus, 1´31˝ at Quercus, P < 0.001), and ignition proceeded normally. Quercus leaves, on the other hand, caught fire but did not ignite successfully. In the second set of experiments utilizing different moisture contents and fuel loads, the maximum flame temperature of the Pinus leaves was significantly higher (421°C at Pinus, 361°C at Quercus, P < 0.001) and the combustion persisted for longer than in the Quercus leaves (8´8˝ at Pinus, 3´38˝ at Quercus, P < 0.001). The moisture contents of the leaves appeared to be a more important factor in the maximum temperature achieved, whereas the most important factor in burning time was the amount of fuel. Overall, these results support the assumption that Pinus leaves can be ignited even by low-heat sources such as cigarettes. Additionally, once ignited, Pinus leaves burn at a relatively high flame temperature and burn for a prolonged period, thus raising the possibility of frequent fire occurrences and spread into crown fires in forests of P. densiflora.

참고문헌 (14)

  1. Aerts R, "Climate, leaf litter chemistry and leaf litter decomposition in terrestrial ecosystems: a triangular relationship", Oikos, 79, pp.439~449 (1997)
  2. Burgan RE, "BEHAVE: Fire Behavior Prediction and Fuel Modeling System-Fuel Subsystem. General Technical Report INT-167. U.S. Department of Agriculture, Forest Service" (1984), Intermountain Forest and Range Experiment Station
  3. Chandler C, "Fire in Forestry: Vol. 1. Forest Fire Behavior and Effects" (1983), John Wiley & Sons
  4. Choung Y, "Forest responses to the large-scale east coast fires in Korea", Ecol Res, 19, pp.43~54 (2004)
  5. Graham JB, "Effects of fine fuel moisture and loading on small scale fire behavior in mixed-oak forests of southeastern Ohio", Fire Ecol, 2, pp.100~114 (2006)
  6. Haessler WM, "Fire: Fundamentals and Control" (1989), Marcel Dekker, Inc
  7. Hely C, "Effects of stand composition on fire hazard in mixed-wood Canadian boreal forest", J Veg Sci, 11, pp.813~824 (2000)
  8. Kim KS, "Moisture content of litter layer and its combustibility by cigarette light in forest", Korean J Ecol, 17, pp.1~9 (1994)
  9. "National forest statistics"[URL]
  10. 이해평, "영동지역의 주요 수종별 낙엽과 생엽의 열적특성 및 발화특성에 관한 연구", 한국화재소방학회 논문지, 23(1), pp.21~32 (2009), 한국화재소방학회
  11. 이시영, "산불발화지점의 임상 및 지형특성을 이용한 위험지수 개발", 한국화재소방학회 논문지, 19(4), pp.75~79 (2005), 한국화재소방학회
  12. 박형주, "복사열을 이용한 소나무와 굴참나무 낙엽의 연소특성 분석", 한국화재소방학회 논문지, 21(3), pp.41~46 (2007), 한국화재소방학회
  13. Seo H, "Comparison of fire vulnerability at Pinus densiflora and Quercus variabilis forests in East Coast of Korea", 석사, pp.2010
  14. Song HK, "Essential oil components of leaves and resins from Pinus densiflora and Pinus koraiensis", Mokchae Konghak, 22, pp.59~67 (1994)