패시브주택과 일반주택의 난방운전특성 비교 분석
Comparative Analysis of Heating Operation Characteristics of Passive Houses and Poor Insulation Houses
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Domestic residential buildings mainly use radiant floor heating. The government is continuously reinforcing the insulation standards, so it is necessary to review the operating conditions and design data of the floor heating system in high insulation conditions. Therefore, in this study, the characteristics of daily heating operation are analyzed for passive design households, and the daily heating energy consumption is compared with the characteristics in existing insulation conditions. As a result of examining the heating operation characteristics for passive houses, it was reasonable to maintain the room temperature even if the heating supply water temperature in the high insulation housing is lowered to 40~50℃. In addition, the passive apartment houses of this study showed that heating energy consumption decreased to about 50% compared with the insulation conditions in 2006. In passive apartment houses, heat loss to the upper and lower floors becomes relatively important as the heat loss through the enclosure decreases. To prevent this, it is necessary to strengthen the insulation against the bottom layer.
Abstract
Domestic residential buildings mainly use radiant floor heating. The government is continuously reinforcing the insulation standards, so it is necessary to review the operating conditions and design data of the floor heating system in high insulation conditions. Therefore, in this study, the characteristics of daily heating operation are analyzed for passive design households, and the daily heating energy consumption is compared with the characteristics in existing insulation conditions. As a result of examining the heating operation characteristics for passive houses, it was reasonable to maintain the room temperature even if the heating supply water temperature in the high insulation housing is lowered to 40~50℃. In addition, the passive apartment houses of this study showed that heating energy consumption decreased to about 50% compared with the insulation conditions in 2006. In passive apartment houses, heat loss to the upper and lower floors becomes relatively important as the heat loss through the enclosure decreases. To prevent this, it is necessary to strengthen the insulation against the bottom layer.
참고문헌 (6)
- 김용기, "패시브 디자인이 적용된 공동주택의 단위세대 난방운전특성 분석", 대한설비공학회 하계학술발표대회 논문집, pp.224~227 (2017)
- 김태원, "바닥 복사 난방시스템에서 PCM 적용에 따른 Mock-up 실험", 설비공학 논문집, 30(11), pp.497~507 (2018), 대한설비공학회[DOI]
- 박승훈, "건물 부하를 포함한 바닥 난방 시스템 모델 제안 및 제어목적 파라미터 최적화 방안", 설비공학 논문집, 30(8), pp.366~375 (2018), 대한설비공학회[DOI]
- 서정아, "공동주택 세대별 난방 성능 개선 연구", 설비공학 논문집, 28(2), pp.69~74 (2016), 대한설비공학회[DOI]
- 은평뉴타운 상림마을 지역난방시스템 성능진단, "에스에이치공사", 한국건설기술연구원, 58~61, pp.연구보고서(KICT 2010-049) (2010)
- 제로카본 그린홈 기반구축 및 기술실용화, "한국건설기술연구원", 17~33, pp.연구보고서(KICT 2014-202) (2014)
