본문 바로가기
KERD
논문KCI 등재

주거건물 단열수준에 따른 발열유리의 난방에너지 성능 평가

Heating Energy Performance of Heated Glass According to Insulation Level of the Residential Building

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류기타공학

초록

Heat losses through exterior windows and condensation on their surface can cause thermal discomfort inside a building. In addition, the use of low energy-efficient windows tends to increase thermal heat losses, and thus building energy consumption. In this study, we present the performance evaluation of heated glass in a residential building when the system is applied to a building and used as a heating system. In this study, a simulation-based analysis was conducted to evaluate the heating energy consumption based on the insulation standards with different areas and types of heating systems in a residential building. The results of this study reveal that the heated glass used a relatively higher heating energy consumption when compared to those of the other two heating systems, including floor radiant heating and air-source heat pump systems. Although the heated glass exhibited the highest energy consumption, it is expected that the system can be used as an alternative to other systems, such as a floor radiating heating system. This is mainly because the heated glass includes high benefits of indoor thermal comfort and prevents the window surface from forming condensation. In terms of combinations of heating systems, a case that includes radiant floor and heated glass heating systems can be considered as the best option based on the study analysis because the traditionally preferred heating method in Korea is based on a radiant floor heating system.

Abstract

Heat losses through exterior windows and condensation on their surface can cause thermal discomfort inside a building. In addition, the use of low energy-efficient windows tends to increase thermal heat losses, and thus building energy consumption. In this study, we present the performance evaluation of heated glass in a residential building when the system is applied to a building and used as a heating system. In this study, a simulation-based analysis was conducted to evaluate the heating energy consumption based on the insulation standards with different areas and types of heating systems in a residential building. The results of this study reveal that the heated glass used a relatively higher heating energy consumption when compared to those of the other two heating systems, including floor radiant heating and air-source heat pump systems. Although the heated glass exhibited the highest energy consumption, it is expected that the system can be used as an alternative to other systems, such as a floor radiating heating system. This is mainly because the heated glass includes high benefits of indoor thermal comfort and prevents the window surface from forming condensation. In terms of combinations of heating systems, a case that includes radiant floor and heated glass heating systems can be considered as the best option based on the study analysis because the traditionally preferred heating method in Korea is based on a radiant floor heating system.

참고문헌 (8)

  1. pp. 151, ", IPCC, Geneva", 2014
  2. 김경아, "창호 구성 요소에 따른 난방에너지 절감율 예측에 관한연구-공동주택을 중심으로", 한국태양에너지학회 논문집, 33(6), pp.54~61 (2013), 한국태양에너지학회
  3. Kurnitski, J., "Efficiency of Electrically Heated Windows", Energy and Buildings, 36(10), pp.1003~1010 (2004)
  4. Ollokiegi, E. A., "Electric Heated Windows", Master, pp.2013
  5. Green Buildings Construction Support Act, "MOLIT", Korean Law Information Center, ~ (2017)
  6. 윤용상, "공동주택의 최적 Glazing 구성에 관한 연구 - Glazing 성능과 냉난방 설정온도를 중심으로 -", 대한건축학회논문집, 28(10), pp.301~308 (2012), 대한건축학회
  7. 박두용, "EnergyPlus와 eQUEST를 이용한 공동주택의 난방에너지소비량 비교분석에 관한 연구", 한국태양에너지학회 논문집, 33(1), pp.48~56 (2013), 한국태양에너지학회
  8. 서혜수, "초고층 공동주택의 세대별 냉난방부하 시뮬레이션 결과 및 에너지 실사용량과의 비교 분석", 한국태양에너지학회 논문집, 31(4), pp.34~40 (2011), 한국태양에너지학회