본문 바로가기
KERD
논문KCI 등재

압축기 바디 진동을 이용한 압축기 내부 고온 냉매 냉각에 대한 연구

A Study on the Cooling of High Temperature Refrigerant Inside a Compressor using Compressor Body Vibration

2

조회

0

다운로드

2

인용

0

참고문헌

키워드

주제분류기계공학

초록

The new thermal management models of linear compressors have been recently reported. These models adopt the simplified transient flow effects to shorten the excessive analysis time. Among the unsteady flow effects of the linear compressor, the effect of the gap flow between the compressor housing and the body due to the body vibration on the heat transfer performance was studied in this paper. For this study, a numerical analysis for the unsteady axisymmetric flows was performed by using CFD (Computational Fluid Dynamics). The results show that the high-speed refrigerant flows occurred in the gap between the compressor housing and the body, which contribute to increasing the heat transfer from high temperature refrigerants in the housing to the outside air. In addition, as the gap decreases, the refrigerant flow rate through the gap increases and the heat transfer rate increases as well.

Abstract

The new thermal management models of linear compressors have been recently reported. These models adopt the simplified transient flow effects to shorten the excessive analysis time. Among the unsteady flow effects of the linear compressor, the effect of the gap flow between the compressor housing and the body due to the body vibration on the heat transfer performance was studied in this paper. For this study, a numerical analysis for the unsteady axisymmetric flows was performed by using CFD (Computational Fluid Dynamics). The results show that the high-speed refrigerant flows occurred in the gap between the compressor housing and the body, which contribute to increasing the heat transfer from high temperature refrigerants in the housing to the outside air. In addition, as the gap decreases, the refrigerant flow rate through the gap increases and the heat transfer rate increases as well.

참고문헌 (12)

  1. H. K. Lee, "Development of the linear compressor for a household refrigerator", Proceedings international compressor engineering conference, pp.31~38 (2000)
  2. S. Porkhial, "Transient characteristic of reciprocating compressor in household refrigerators", Applied thermal engineering, 26(14), pp.1725~1729 (2002)
  3. X. Hou, "Analysis of efficiency and power facor of reciprocating compressor unit under variable frequency and variable conditions", Proceedings international compressor engineering conference (2008)
  4. Yong-sik Choi, "Dynamic behavior of valve system in linear compressor based on fluid-structure interaction", Journal of Mechanical Science and Technology, 24(7), pp.1371~1377 (2010), 대한기계학회
  5. I. S. Hwang, "Linear compressor discharge", International journal of refrigeration, 82, pp.509~519 (2017)
  6. H. Kim, "An experimental and numerical study on dynamic characteristic of linear compressor in refrigeration system", International journal of refrigeration, 31, pp.1536~1543 (2009)
  7. H. Bukac, "Understanding valve Dynamics", Proceedings international compressor engineering conference (2002)
  8. P. Binneberg, "Reduction in power consumption of household refrigerators by using variable speed compressor", International refrigeration and air conditioning conference (2002)
  9. L. R. Silva, "Modeling of gas leakage through compressor valves", International Journal of Refrigeration, 53, pp.195~205 (2014)
  10. M. J. Oliverira, "Modeling thermal compressor reciprocal linear operating without oil lube", Federal de santa catarina university, 101~111 (2014)
  11. I. S. Hwang, "CFD analysis of transient flows in a linear compressor using a 1D-CFD coupled model", International journal of refrigeration, 91, pp.20~27 (2018)
  12. "Ansys Fluent version 15", Ansys Inc, ~