본문 바로가기
KERD
논문KCI 등재

심야전력을 이용한 Cascade Heat Pump Cycle의 운전결과 분석

Analysis on Cascade Cycle Heat Pump Application as Night Storage Heater

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류기계공학

초록

To analyze and verify the effect of replacing thermal storage heater by a cascade cycle heat pump using midnight electricity was installed and tested at a customer's house in Wonju, Korea. The electric night storage heater is consist of 30kW electric heater and 2,700 liters of thermal storage water tank to supply hot water for warming house floor. The power for electric heater was cut off and hot water was only generated by cascade cycle heat pump. Current thermal storage water tank was not eliminated and electric heater wiring was modified. Some operation logic of the heat pump was also modified for proper operation. The required capacity of the heat pump and hot water temperature for given warming condition were estimated. The estimated capacity of heat pump was about 19kW and estimated hot water temperature for proper heating was at least 75℃.

Abstract

To analyze and verify the effect of replacing thermal storage heater by a cascade cycle heat pump using midnight electricity was installed and tested at a customer's house in Wonju, Korea. The electric night storage heater is consist of 30kW electric heater and 2,700 liters of thermal storage water tank to supply hot water for warming house floor. The power for electric heater was cut off and hot water was only generated by cascade cycle heat pump. Current thermal storage water tank was not eliminated and electric heater wiring was modified. Some operation logic of the heat pump was also modified for proper operation. The required capacity of the heat pump and hot water temperature for given warming condition were estimated. The estimated capacity of heat pump was about 19kW and estimated hot water temperature for proper heating was at least 75℃.

참고문헌 (7)

  1. 해양 심층수 개발 및 활용을 위한 법 제화 검토 연구, "김정봉", 한국해양 수산개발원, 13~30 (2003)
  2. 공기 열원을 이용한 축열식 냉난방 시 스템 연구, "김옥중", 대한설비공학회, 1125~1130 (2006)
  3. 심야보일러 대체용 Cascade Cycke 히 트펌프 적용에 따른 성능평가, "정훈", 한국기계기술학회, ~ (2010)
  4. 심야기기의 이용과 설치, "한국전력공사", 영업처, ~ (1988)
  5. 히트파이프를 이용한 축열식 냉난방 시스템에 관한 연구, "김성실", 대한설비공학회, ~ (2006)
  6. 심야전력제도의 문제점과 개선방향: 경제성, 환경성, 형평성 및 에너지 안보, "조영탁", 한국환경경제학회, ~ (2008)
  7. ASHRAE STANDARD, "Energy Standard for Building Except Low-Rise Residential Buildings", ~ (2007)