Combat-armored vehicles were equipped with an automatic-fire-extinguishing system to ensure the safety of the crew and vehicle from fires on the vehicle. When a fire was occurred, the automatic-fire-extinguishing system automatically detects the fire through sensors and detection lines, sprays a fire extinguisher, and notifies the crew visually and audibly. Recently, there had been cases of automatic-fire-extinguishing systems malfunction on combat-armored vehicles. In this study, in order to resolve the automatic-fire-extinguisher's malfunction phenomenon, ground noise and inter-circuit noise generated from the fire detection line were identified, and the resistance connected on the circuit was revised to remove noise. As a result of resistance revision, the noises was eliminated and the electromotive force difference between input circuits was made constant, thereby improving the malfunction of the automatic-fire-extinguishing system. By applying the result, it was confirmed that the control device sensed a temperature similar to the actual temperature on actual vehicles, and it was confirmed that the automatic-fire-extinguishing system's malfunction phenomenon was not founded in the field vehicles after then.
Abstract
Combat-armored vehicles were equipped with an automatic-fire-extinguishing system to ensure the safety of the crew and vehicle from fires on the vehicle. When a fire was occurred, the automatic-fire-extinguishing system automatically detects the fire through sensors and detection lines, sprays a fire extinguisher, and notifies the crew visually and audibly. Recently, there had been cases of automatic-fire-extinguishing systems malfunction on combat-armored vehicles. In this study, in order to resolve the automatic-fire-extinguisher's malfunction phenomenon, ground noise and inter-circuit noise generated from the fire detection line were identified, and the resistance connected on the circuit was revised to remove noise. As a result of resistance revision, the noises was eliminated and the electromotive force difference between input circuits was made constant, thereby improving the malfunction of the automatic-fire-extinguishing system. By applying the result, it was confirmed that the control device sensed a temperature similar to the actual temperature on actual vehicles, and it was confirmed that the automatic-fire-extinguishing system's malfunction phenomenon was not founded in the field vehicles after then.
참고문헌 (5)
- 곽지현, "자동확산소화장치의 이격거리에 따른 소화성능평가연구", 한국화재소방학회 논문지, 27(5), pp.38~43 (2013), 한국화재소방학회[DOI]
- 김민수, "열전소자를 이용한 냉동기의 과냉 시스템에 관한 연구", 한국기계기술학회지, 20(2), pp.148~153 (2018), 한국기계기술학회[DOI]
- 박준영, "경기관총-Ⅱ 조준장치(PAS-18K)의 열상 화면 노이즈에 대한 IPB 모듈개선 연구 및 수율개선", 한국기계기술학회지, 25(4), pp.576~583 (2023), 한국기계기술학회[DOI]
- 방준호, "병렬연결법에 의한 1.8V CMOS Self-bias 고속 차동증폭기의 이득 개선", 전기학회논문지ABCD, 57(10), pp.1888~1892 (2008), 대한전기학회
- 조대훈, "노이즈 저감을 위한 접지시스템 진단 엔지니어링", 전기학회논문지, 65(7), pp.1290~1294 (2016), 대한전기학회[DOI]