In this study, fire extinguisher system to which form fire extinguisher agents were adopted was applied to the combat vehicle crew room to apply fire extinguishing performance and acid gas safety that meet the national defense standards. As a result of evaluation and verification, the following conclusions were drawn. For standard fire sizes in the combat vehicle crew's standard model, we ignited using a mixture of Novec 1230 and Halon 1301 form extinguisher agent and released form extinguisher agent after 30 seconds to determine the fire extinguishing time. The amount of acid gas generated met the criteria in all cases. When the fire size was increased to 0.12m2 and a 2.0mm nozzle was used, all of the extinguishing time, the amount of acid gas generated, and the concentration of Novec 1230 met the criteria. Despite the more difficult conditions to extinguish the fire by making the fire larger, it was possible to confirm the extinguishing performance of the Novec 1230 form extinguisher agent and its safety against acid gas.
Abstract
In this study, fire extinguisher system to which form fire extinguisher agents were adopted was applied to the combat vehicle crew room to apply fire extinguishing performance and acid gas safety that meet the national defense standards. As a result of evaluation and verification, the following conclusions were drawn. For standard fire sizes in the combat vehicle crew's standard model, we ignited using a mixture of Novec 1230 and Halon 1301 form extinguisher agent and released form extinguisher agent after 30 seconds to determine the fire extinguishing time. The amount of acid gas generated met the criteria in all cases. When the fire size was increased to 0.12m2 and a 2.0mm nozzle was used, all of the extinguishing time, the amount of acid gas generated, and the concentration of Novec 1230 met the criteria. Despite the more difficult conditions to extinguish the fire by making the fire larger, it was possible to confirm the extinguishing performance of the Novec 1230 form extinguisher agent and its safety against acid gas.
참고문헌 (11)
- W, S. Lim, "A Study on Fire Extinguishing Ability Evaluation of Gaseous Extinguishing Agents", KIFSE, 2009 Spring Conference, pp.483~486 (2009)
- NFPA 2001, "Standard on Clean Agent Fire Extinguishing Systems", ~ (2012)
- Measuring the Impact of Fire Extinguisher Agents on Cultural Resource Materials, "Hughes Associates, Inc", The Fire Protection Research Foundation, NFPA, ~ (2010)
- S. E. Hodges, "Fire Extinguishing Agents for Protection of Occupied Space in Military Ground Vehicles", Proceedings of NFPA SUPDET Conference, pp.1~17 (2010)
- A Study on Fire Extinguishing Ability Evaluation of Gaseous Extinguishing Agents, , Ministry of Public Safety and Security Notice, ~, pp.2015-1 (2015)
- A. K. Kim, "Performance of Novec 1230 in Electronic Facility Fire Protection", Proceedings of NFPA SUPDET Conference, pp.1~6 (2010)
- D. M. Ha, "Measurement and Investigation of Combustible Properties of n-Heptane for Risk Assessment of Gasoline Tank", KIFSE, Journal of KIFSE, 24(6), pp.76~81 (2010)
- The Characterstics of the Exhaust Gas Emission by Fuel Types, "National Institute of Environmental Research Report", ~ (2004)
- J. Z. Su, "Suppression of Pool Fires Using Halocarbon Streaming Agents", Fire Technology, 38(1), pp.7~32 (2002)
- Establishment of safety standards for acid gas in automatic fire extinguishing devices for orbital equipment, "Army Headquarters Report", ~ (2016)
- B. D. Ditch, "Thermal Decomposition Products Testing with 1, 1, 1, 2, 2, 4, 5, 5, 5 nonfloro-4-trifluoro methyl pentan-3-one(C6 F-ketone)during Fire Extinguishing", pp.2002