Relationship between Scanning Laser Polarimetry with Enhanced Corneal Compensation and with Variable Corneal Compensation
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose: To evaluate the structure-function relationships between retinal sensitivity measured by Humphrey visual field analyzer (HVFA) and the retinal nerve fiber layer (RNFL) thickness measured by scanning laser polarimetry (SLP) with variable corneal compensation (VCC) and enhanced corneal compensation (ECC) in glaucomatous and healthy eyes. Methods: Fifty-three eyes with an atypical birefringence pattern (ABP) based on SLP-VCC (28 glaucomatous eyes and 25 normal healthy eyes) were enrolled in this cross-sectional study. RNFL thickness was measured by both VCC and ECC techniques, and the visual field was examined by HVFA with 24-2 full-threshold program. The relationships between RNFL measurements in superior and inferior sectors and corresponding retinal mean sensitivity were sought globally and regionally with linear regression analysis in each group. Coefficients of the determination were calculated and compared between VCC and ECC techniques. Results: In eyes with ABP, R2 values for the association between SLP parameters and retinal sensitivity were 0.06-0.16 with VCC, whereas they were 0.21-0.48 with ECC. The association of RNFL thickness with retinal sensitivity was significantly better with ECC than with VCC in 5 out of 8 regression models between SLP parameters and HVF parameters (P<0.05). Conclusions: The strength of the structure-function association was higher with ECC than with VCC in eyes with ABP, which suggests that the ECC algorithm is a better approach for evaluating the structure-function relationship in eyes with ABP.
Abstract
Purpose: To evaluate the structure-function relationships between retinal sensitivity measured by Humphrey visual field analyzer (HVFA) and the retinal nerve fiber layer (RNFL) thickness measured by scanning laser polarimetry (SLP) with variable corneal compensation (VCC) and enhanced corneal compensation (ECC) in glaucomatous and healthy eyes. Methods: Fifty-three eyes with an atypical birefringence pattern (ABP) based on SLP-VCC (28 glaucomatous eyes and 25 normal healthy eyes) were enrolled in this cross-sectional study. RNFL thickness was measured by both VCC and ECC techniques, and the visual field was examined by HVFA with 24-2 full-threshold program. The relationships between RNFL measurements in superior and inferior sectors and corresponding retinal mean sensitivity were sought globally and regionally with linear regression analysis in each group. Coefficients of the determination were calculated and compared between VCC and ECC techniques. Results: In eyes with ABP, R2 values for the association between SLP parameters and retinal sensitivity were 0.06-0.16 with VCC, whereas they were 0.21-0.48 with ECC. The association of RNFL thickness with retinal sensitivity was significantly better with ECC than with VCC in 5 out of 8 regression models between SLP parameters and HVF parameters (P<0.05). Conclusions: The strength of the structure-function association was higher with ECC than with VCC in eyes with ABP, which suggests that the ECC algorithm is a better approach for evaluating the structure-function relationship in eyes with ABP.
참고문헌 (25)
- Reus NJ, "The relationship between standard automated perimetry and GDx-VCC measurements", Invest Ophthalmol Vis Sci, 45, pp.840~5 (2004)
- Lan YW, "The correlation between optic nerve head topographic measurements, peripapillary nerve fiber layer thickness, and visual field indices in glaucoma", Br J Ophthalmol, 87, pp.1135~41 (2003)
- Schlottmann PG, "Relationship between visual field sensitivity and retinal nerve fiber layer thickness as measured by scanning laser polarimetry", Invest Ophthalmol Vis Sci, 45, pp.1823~9 (2004)
- Greenfield DS, "Optic nerve and retinal nerve fiber layer analyzers in glaucoma", Curr Opin Ophthalmol, 13, pp.68~76 (2002)
- Blumenthal EZ, "Assessment of the retinal nerve fiber layer in clinical trials of glaucoma neuroprotection", Surv Ophthalmol, 45(3), pp.S305~12 (2001)
- Bagga H, "Quantitative assessment of structural damage in eyes with localized visual field abnormalities", Am J Ophthalmol, 137, pp.797~804 (2004)
- Zhou Q, "Individualizd compensation of anterior segment birefringence during scanning laser polarimetry", Invest Ophthalmol Vis Sci, 43, pp.2221~8 (2002)
- Weinreb RN, "Glaucoma detection using scanning laser polarimetry with variable corneal polarization compensation", Arch Ophthalmol, 121, pp.218~24 (2003)
- Kook MS, "Scanning laser polarimetry using variable corneal compensation in the detection of glaucoma with localized visual field defects", Ophthalmology, 112, pp.1970~8 (2005)
- Frenkel S, "Operator learning effect and interoperator reproducibility of the scanning laser polarimeter with variable corneal compensation", Ophthalmology, 112, pp.257~61 (2005)
- Lleo-Perez A, "Intraobserver reproducibility of retinal nerve fiber layer measurements using scanning laser polarimetry and optical coherence tomography in normal and ocular hypertensive subjects", Eur J Ophthalmol, 14, pp.523~30 (2004)
- Bozkurt B, "Effect of peripapillary chorioretinal atrophy on GDx parameters in patients with degenerative myopia", Clin Experiment Ophthalmol, 30, pp.411~4 (2002)
- Tóth M, "Enhanced corneal compensation for scanning laser polarimetry on eyes with atypical polarisation pattern", Br J Ophthalmol, 89, pp.1139~42 (2005)
- Hoh ST, "Factors affecting image acquisition during scanning laser polarimetry", Ophthalmic Surg Lasers, 29, pp.545~51 (1998)
- Da Pozzo S, "Atypical pattern of retardation on GDx-VCC and its effect on retinal nerve fiber layer evaluation in glaucomatous eyes", Eye, 20, pp.767~75 (2006)
- Tóth M, "Evaluation of enhanced corneal compensation in scanning laser polarimetry: comparison with variable corneal compensation on human eyes undergoing LASIK", J Glaucoma, 15, pp.53~9 (2006)
- Reus NJ, "Enhanced imaging algorithm for scanning laser polarimetry with variable corneal compensation", Invest Ophthalmol Vis Sci, 47, pp.3870~7 (2006)
- Sehi M, "An enhancement module to improve the atypical birefringence pattern using scanning laser polarimetry with variable corneal compensation", Br J Ophthalmol, 90, pp.749~53 (2006)
- Bowd C, "Retinal Nerve Fiber Layer Thickness and Visual Sensitivity Using Scanning Laser Polarimetry with Variable and Enhanced Corneal Compensation", Ophthalmology, 144, pp.1259~65 (2007)
- Mai TA, "Structure‐function relationship is stronger with enhanced corneal compensation than with variable corneal compensation in scanning laser polarimetry", Invest Ophthalmol Vis Sci, 48, pp.1651~8 (2007)
- Garway-Heath DF, "Mapping the visual field to the optic disc in normal tension glaucoma eyes", Ophthalmology, 107, pp.1809~15 (2000)
- Choi J, "Scanning laser polarimetry with variable corneal compensation in the area of apparently normal hemifield in eyes with normal tension glaucoma", Ophthalmology, 113, pp.1954~60 (2006)
- Reus NJ, "Relationships between standard automated perimetry, HRT confocal scanning laser ophthalmoscopy, and GDx-VCC scanning laser polarimetry", Invest Ophthalmol Vis Sci, 46, pp.4182~8 (2005)
- Bowd C, "Association between scanning laser polarimetry measurements using variable corneal polarization compensation and visual field sensitivity in glaucomatous eyes", Arch Ophthalmol, 121, pp.961~6 (2003)
- Fedeiros FA, "Comparison of the GDx-VCC scanning laser polarimeter, HRT II confocal scanning laser ophthalmoscope, and StratusOCT optical coherence tomography for the detection of glaucoma", Arch Ophthalmol, 122, pp.827~37 (2004)
