본문 바로가기
KERD
논문KCI 등재

Accuracy of Intraocular Lens Power Calculation Formulas in Primary Angle Closure Glaucoma

2

조회

0

다운로드

2

인용

0

참고문헌

키워드

주제분류안과학

초록

Purpose: To compare the accuracy of intraocular lens (IOL) power calculation formulas in eyes with primary angle closure glaucoma (ACG). Methods: This retrospective study compared the refractive outcomes of 63 eyes with primary ACG with the results of 93 eyes with normal open angles undergoing uneventful cataract surgery. Anterior segment biometry including anterior chamber depth, axial length, and anterior chamber depth to axial length ratio were compared by the IOL Master. Third generation formulas (Hoffer Q and SRK/T) and a fourth generation formula (Haigis) were used to predict IOL powers in both groups. The predictive accuracy of the formulas was analyzed by comparison of the mean error and the mean absolute error (MAE). Results: In ACG patients, anterior chamber depth and the anterior chamber depth to axial length ratio were smaller than normal controls (all p < 0.05). The MAEs from the ACG group were larger than that from the control group in the Haigis formula. The mean absolute error from the Haigis formula was the largest and the mean absolute error from the Hoffer Q formula was the smallest. Conclusions: IOL power prediction may be inaccurate in ACG patients. The Haigis formula produced more inaccurate results in ACG patients, and it is more appropriate to use the Hoffer Q formula to predict IOL powers in eyes with primary ACG.

Abstract

Purpose: To compare the accuracy of intraocular lens (IOL) power calculation formulas in eyes with primary angle closure glaucoma (ACG). Methods: This retrospective study compared the refractive outcomes of 63 eyes with primary ACG with the results of 93 eyes with normal open angles undergoing uneventful cataract surgery. Anterior segment biometry including anterior chamber depth, axial length, and anterior chamber depth to axial length ratio were compared by the IOL Master. Third generation formulas (Hoffer Q and SRK/T) and a fourth generation formula (Haigis) were used to predict IOL powers in both groups. The predictive accuracy of the formulas was analyzed by comparison of the mean error and the mean absolute error (MAE). Results: In ACG patients, anterior chamber depth and the anterior chamber depth to axial length ratio were smaller than normal controls (all p < 0.05). The MAEs from the ACG group were larger than that from the control group in the Haigis formula. The mean absolute error from the Haigis formula was the largest and the mean absolute error from the Hoffer Q formula was the smallest. Conclusions: IOL power prediction may be inaccurate in ACG patients. The Haigis formula produced more inaccurate results in ACG patients, and it is more appropriate to use the Hoffer Q formula to predict IOL powers in eyes with primary ACG.

참고문헌 (22)

  1. Drexler W, "Partial coherence interferometry:a novel approach to biometry in cataract surgery", Am J Ophthalmol, 126, pp.524~534 (1998)
  2. Lee AC, "Biometry and intraocular lens power calculation", Curr Opin Ophthalmol, 19, pp.13~17 (2008)
  3. Terzi E, "Accuracy of modern intraocular lens power calculation formulas in refractive lens exchange for high myopia and high hyperopia", J Cataract Refract Surg, 35, pp.1181~1189 (2009)
  4. Ucakhan OO, "Anterior chamber parameters measured by the Pentacam CES after uneventful phacoemulsification in normotensive eyes", Acta Ophthalmol, 87, pp.544~548 (2009)
  5. Nonaka A, "Angle widening and alteration of ciliary process configuration after cataract surgery for primary angle closure", Ophthalmology, 113, pp.437~441 (2006)
  6. Hayashi K, "Changes in anterior chamber angle width and depth after intraocular lens implantation in eyes with glaucoma", Ophthalmology, 107, pp.698~703 (2000)
  7. Yang CH, "Intraocular lens position and anterior chamber angle changes after cataract extraction in eyes with primary angle-closure glaucoma", J Cataract Refract Surg, 23, pp.1109~1113 (1997)
  8. Law SK, "Effects of combined cataract surgery and trabeculectomy with mitomycin C on ocular dimensions", Br J Ophthalmol, 89, pp.1021~1025 (2005)
  9. Francis BA, "Changes in axial length following trabeculectomy and glaucoma drainage device surgery", Br J Ophthalmol, 89, pp.17~20 (2005)
  10. Sung Yong Kang, "Inaccuracy of Intraocular Lens Power Prediction for Cataract Surgery in Angle-Closure Glaucoma", Yonsei Medical Journal, 50(2), pp.206~210 (2009), 연세대학교의과대학
  11. Santodomingo-Rubido J, "A new non-contact optical device for ocular biometry", Br J Ophthalmol, 86, pp.458~462 (2002)
  12. Findl O, "High precision biometry of pseudophakic eyes using partial coherence interferometry", J Cataract Refract Surg, 24, pp.1087~1093 (1998)
  13. Haigis W, "Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis", Graefes Arch Clin Exp Ophthalmol, 238, pp.765~773 (2000)
  14. Charalampidou S, "Effect on refractive outcomes after cataract surgery of intraocular lens constant personalization using the Haigis formula", J Cataract Refract Surg, 36, pp.1081~1089 (2010)
  15. Elder MJ, "Predicting the refractive outcome after cataract surgery:the comparison of different IOLs and SRK-II v SRK-T", Br J Ophthalmol, 86, pp.620~622 (2002)
  16. Marchini G, "Ultrasound biomicroscopic and conventional ultrasonographic study of ocular dimensions in primary angle-closure glaucoma", Ophthalmology, 105, pp.2091~2098 (1998)
  17. Lowe RF, "Causes of shallow anterior chamber in primary angle-closure glaucoma.Ultrasonic biometry of normal and angle-closure glaucoma eyes", Am J Ophthalmol, 67, pp.87~93 (1969)
  18. Narvaez J, "Accuracy of intraocular lens power prediction using the Hoffer Q,Holladay 1,Holladay 2,and SRK", T formulas, 2006, pp.32, 2050~2053
  19. Hoffer KJ, "The Hoffer Q formula:a comparison of theoretic and regression formulas", J Cataract Refract Surg, 19, pp.700~712 (1993)
  20. Haigis W, "IOL power calculations", Ophthalmology, 117, pp.400~401 (2010)
  21. Gavin EA, "Intraocular lens power calculation in short eyes", Eye(Lond), 22, pp.935~938 (2008)
  22. MacLaren RE, "Biometry and formula accuracy with intraocular lenses used for cataract surgery in extreme hyperopia", Am J Ophthalmol, 143, pp.920~931 (2007)

관련 논문AI추천

이 간행물의 다른 논문 (16건)