Purpose: To compare the accuracy of intraocular lens (IOL) power calculation using conventional regressionformulae or the American Society of Cataract and Refractive Surgery (ASCRS) IOL power calculator for previouscorneal refractive surgery. Methods: We retrospectively reviewed 96 eyes from 68 patients that had undergone cataract surgery afterkeratorefractive surgeries. We calculated the formula with two approaches: IOL powers using the ASCRSIOL power calculator and IOL powers using conventional formulae with previous refractive data (Camellin,Jarade, Savini, and clinical history method) or without prior data (0, 2 and, 4 mm total mean power in topography,Wang-Koch-Maloney, Shammas, Seitz, and Maloney). Two conventional IOL formulae (the SRK/T andthe Hoffer Q) were calculated with the single K and double K methods. Mean arithmetic refractive error andmean absolute error were calculated at the first postoperative month. Results: In conventional formulae, the Jarade method or the Seitz method, applied in the Hoffer Q formulawith the single K or double K method, have the lowest prediction errors. The least prediction error was foundin the Shammas-PL method in the ASCRS group. There was no statistically significant difference betweenthe 10 lowest mean absolute error conventional methods, the Shammas-PL method and the Barrett True-Kmethod calculated with using the ASCRS calculator, without using preoperative data. Conclusions: The Shammas-PL formula and the Barrett True-K formula, calculated with the ASCRS calculator,without using history, were methods comparable to the 10 most accurate conventional formulae. Othermethods using the ASCRS calculator show a myopic tendency.

Abstract

Purpose: To compare the accuracy of intraocular lens (IOL) power calculation using conventional regressionformulae or the American Society of Cataract and Refractive Surgery (ASCRS) IOL power calculator for previouscorneal refractive surgery. Methods: We retrospectively reviewed 96 eyes from 68 patients that had undergone cataract surgery afterkeratorefractive surgeries. We calculated the formula with two approaches: IOL powers using the ASCRSIOL power calculator and IOL powers using conventional formulae with previous refractive data (Camellin,Jarade, Savini, and clinical history method) or without prior data (0, 2 and, 4 mm total mean power in topography,Wang-Koch-Maloney, Shammas, Seitz, and Maloney). Two conventional IOL formulae (the SRK/T andthe Hoffer Q) were calculated with the single K and double K methods. Mean arithmetic refractive error andmean absolute error were calculated at the first postoperative month. Results: In conventional formulae, the Jarade method or the Seitz method, applied in the Hoffer Q formulawith the single K or double K method, have the lowest prediction errors. The least prediction error was foundin the Shammas-PL method in the ASCRS group. There was no statistically significant difference betweenthe 10 lowest mean absolute error conventional methods, the Shammas-PL method and the Barrett True-Kmethod calculated with using the ASCRS calculator, without using preoperative data. Conclusions: The Shammas-PL formula and the Barrett True-K formula, calculated with the ASCRS calculator,without using history, were methods comparable to the 10 most accurate conventional formulae. Othermethods using the ASCRS calculator show a myopic tendency.

참고문헌 (21)

  1. Hamilton DR, "Cataract surgery in patients with prior refractive surgery", Curr Opin Ophthalmol, 14, pp.44~53 (2003)
  2. Speicher L, "Intra-ocular lens calculation status after corneal refractive surgery", Curr Opin Ophthalmol, 12, pp.17~29 (2001)
  3. Koch DD, "Refractive complications of cataract surgery after radial keratotomy", Am J Ophthalmol, 108, pp.676~682 (1989)
  4. Odenthal MT, "Clinical and theoretical results of intraocular lens power calculation for cataract surgery after photorefractive keratectomy for myopia", Arch Ophthalmol, 120, pp.431~438 (2002)
  5. Seitz B, "Underestimation of intraocular lens power for cataract surgery after myopic photorefractive keratectomy", Ophthalmology, 106, pp.693~702 (1999)
  6. Borasio E, "Estimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery: BESSt formula", J Cataract Refract Surg, 32, pp.2004~2014 (2006)
  7. Hoffer KJ, "Intraocular lens power calculation for eyes after refractive keratotomy", J Refract Surg, 11, pp.490~493 (1995)
  8. Aramberri J, "Intraocular lens power calculation after corneal refractive surgery: double-K method", J Cataract Refract Surg, 29, pp.2063~2068 (2003)
  9. Camellin M, "A new formula for intraocular lens power calculation after refractive corneal surgery", J Refract Surg, 22, pp.187~199 (2006)
  10. Savini G, "Intraocular lens power calculation after myopic refractive surgery: theoretical comparison of different methods", Ophthalmology, 113, pp.1271~1282 (2006)
  11. Jarade EF, "New formula for calculating intraocular lens power after laser in situ keratomileusis", J Cataract Refract Surg, 30, pp.1711~1715 (2004)
  12. Seitz B, "Intraocular lens calculations status after corneal refractive surgery", Curr Opin Ophthalmol, 11, pp.35~46 (2000)
  13. Savini G, "Intraocular lens power calculation after myopic excimer laser surgery: clinical comparison of published methods", J Cataract Refract Surg, 36, pp.1455~1465 (2010)
  14. Shammas HJ, "Correcting the corneal power measurements for intraocular lens power calculations after myopic laser in situ keratomileusis", Am J Ophthalmol, 136, pp.426~432 (2003)
  15. Wang L, "Comparison of intraocular lens power calculation methods in eyes that have undergone LASIK", Ophthalmology, 111, pp.1825~1831 (2004)
  16. Smith RJ, "The prediction of surgically induced refractive change from corneal topography", Am J Ophthalmol, 125, pp.44~53 (1998)
  17. Barrett GD, "An improved universal theoretical formula for intraocular lens power prediction", J Cataract Refract Surg, 19, pp.713~720 (1993)
  18. Wang L, "Evaluation of intraocular lens power prediction methods using the American Society of Cataract and Refractive Surgeons Post-Keratorefractive Intraocular Lens Power Calculator", J Cataract Refract Surg, 36, pp.1466~1473 (2010)
  19. Chen X, "Metaanalysis of intraocular lens power calculation after laser refractive surgery in myopic eyes", J Cataract Refract Surg, 42, pp.163~170 (2016)
  20. Abulafia A, "Accuracy of the Barrett True-K formula for intraocular lens power prediction after laser in situ keratomileusis or photorefractive keratectomy for myopia", J Cataract Refract Surg, 42, pp.363~369 (2016)
  21. Shammas HJ, "No-history method of intraocular lens power calculation for cataract surgery after myopic laser in situ keratomileusis", J Cataract Refract Surg, 33, pp.31~36 (2007)

관련 논문AI추천

Comparison of Intraocular Lens Power Calculation Methods Following Myopic Laser Refractive Surgery: New Options Using a Rotating Scheimpflug Camera양찬민, 임동희, 정의상, 정태영, 조규연대한안과학회 · Korean Journal of Ophthalmology2018 · 제32권 제6호The Comparison of Central and Mean True-Net Power (Pentacam) in Calculating IOL-Power After Refractive Surgery김상우, 김응권, 김태임, 신주연, 이정호, 조범진, 하병진대한안과학회 · Korean Journal of Ophthalmology2009 · 제23권 제1호미국백내장굴절수술학회 제공 공식을 포함한 굴절교정수술 후 백내장수술 환자의 인공수정체 도수 계산 방법 비교정소연, 정지원대한안과학회 · 대한안과학회지2018 · 제59권 제9호Comparison of Accuracy of Six Modern Intraocular Lens Power Calculation FormulasJi Hyun Yoon, Woong-Joo Whang대한안과학회 · Korean Journal of Ophthalmology2023 · 제37권 제5호Accuracy of the Kane Formula for Intraocular Lens Power Calculation in Comparison with Existing Formulas: A Retrospective Review김응권, 김태임, 류소영, 서경률, 전익현연세대학교의과대학 · Yonsei Medical Journal2021 · 제62권 제12호Refractive Predictability between Standard and Total Keratometry during the Femtosecond Laser-Assisted Cataract Surgery with Monofocal Intraocular Lens with Enhanced Intermediate FunctionHungwon Tchah, Hun Lee, Hyunah Lim, Jae Yong Kim, Joon Hyuck Jang, Koeun Lee, Sanghyu Nam대한안과학회 · Korean Journal of Ophthalmology2024 · 제38권 제1호

이 간행물의 다른 논문 (14건)