Purpose: To evaluate the influence of biometric variables on refractive outcomes after cataract surgery in angle-closure glaucoma (ACG) patients. Methods: In this case-control study, 42 ACG patients, 40 open-angle glaucoma (OAG) patients, and 35 controlswithout glaucoma who had undergone conventional cataract surgery were enrolled consecutively. Electronicmedical records, including preoperative biometric variables (keratometric diopter, axial length, anterior chamberdepth, and lens thickness), the refractive change (RC), and the absolute value of refractive change (ARC)were reviewed. Results: In the control and OAG patients, the anterior chamber depth was negatively correlated with the ARC(r = -0.344, p = 0.043 and r = -0.431, p = 0.006, respectively), whereas there was no correlation in the ACGpatients. Lens thickness was positively correlated with the RC, but not with the ARC, in the control and OAGgroups (r = 0.391, p = 0.020 and r = 0.501, p = 0.001, respectively). In contrast, lens thickness in the ACGgroup was not correlated with the RC but was positively correlated with the ARC (r = 0.331, p = 0.032). Conclusions: In contrast with the anterior chamber depth, preoperatively measured lens thickness may be auseful predictor of the direction of the RC after cataract surgery in control and OAG patients. However, in ACGpatients, a thicker lens was correlated with a larger RC, regardless of the direction of the shift (hyperopic ormyopic).

Abstract

Purpose: To evaluate the influence of biometric variables on refractive outcomes after cataract surgery in angle-closure glaucoma (ACG) patients. Methods: In this case-control study, 42 ACG patients, 40 open-angle glaucoma (OAG) patients, and 35 controlswithout glaucoma who had undergone conventional cataract surgery were enrolled consecutively. Electronicmedical records, including preoperative biometric variables (keratometric diopter, axial length, anterior chamberdepth, and lens thickness), the refractive change (RC), and the absolute value of refractive change (ARC)were reviewed. Results: In the control and OAG patients, the anterior chamber depth was negatively correlated with the ARC(r = -0.344, p = 0.043 and r = -0.431, p = 0.006, respectively), whereas there was no correlation in the ACGpatients. Lens thickness was positively correlated with the RC, but not with the ARC, in the control and OAGgroups (r = 0.391, p = 0.020 and r = 0.501, p = 0.001, respectively). In contrast, lens thickness in the ACGgroup was not correlated with the RC but was positively correlated with the ARC (r = 0.331, p = 0.032). Conclusions: In contrast with the anterior chamber depth, preoperatively measured lens thickness may be auseful predictor of the direction of the RC after cataract surgery in control and OAG patients. However, in ACGpatients, a thicker lens was correlated with a larger RC, regardless of the direction of the shift (hyperopic ormyopic).

참고문헌 (26)

  1. Kelman CD, "Phaco-emulsification and aspiration: a new technique of cataract removal. A preliminary report", Am J Ophthalmol, 64, pp.23~35 (1967)
  2. Retzlaff JA, "Development of the SRK", T intraocular lens implant power calculation formula, 1990, pp.16, 333~340
  3. Hoffer KJ, "The Hoffer Q formula: a comparison of theoretic and regression formulas", J Cataract Refract Surg, 19, pp.700~712 (1993)
  4. Holladay JT, "A three-part system for refining intraocular lens power calculations", J Cataract Refract Surg, 14, pp.17~24 (1988)
  5. Haigis W, "Occurrence of erroneous anterior chamber depth in the SRK", T formula, 1993, pp.19, 442~446
  6. Yang CH, "Intraocular lens position and anterior chamber a ngle changes after cataract extraction in eyes with primary angle-closure glaucoma", J Cataract Refract Surg, 23, pp.1109~1113 (1997)
  7. Hayashi K, "Changes in anterior chamber angle width and depth after intraocular lens implantation in eyes with glaucoma", Ophthalmology, 107, pp.698~703 (2000)
  8. Hayashi K, "Effect of cataract surgery on intraocular pressure control in glaucoma patients", J Cataract Refract Surg, 27, pp.1779~1786 (2001)
  9. Shingleton BJ, "Longterm changes in intraocular pressure after clear corneal phacoemulsification: normal patients versus glaucoma suspect and glaucoma patients", J Cataract Refract Surg, 25, pp.885~890 (1999)
  10. Tham CC, "Phacoemulsification versus trabeculectomy in medically uncontrolled chronic angle-closure glaucoma without cataract", Ophthalmology, 120, pp.62~67 (2013)
  11. Husain R, "Initial management of acute primary angle closure: a randomized trial comparing phacoemulsification with laser peripheral iridotomy", Ophthalmology, 119, pp.2274~2281 (2012)
  12. Olsen T, "Prediction of the effective postoperative (intraocular lens) anterior chamber depth", J Cataract Refract Surg, 32, pp.419~424 (2006)
  13. Lowe RF, "Aetiology of the anatomical basis for primary angle-closure glaucoma: biometrical comparisons between normal eyes and eyes with primary angle-closure glaucoma", Br J Ophthalmol, 54, pp.161~169 (1970)
  14. Markowitz SN, "Angle-closure glaucoma: relation between lens thickness, anterior chamber depth and age", Can J Ophthalmol, 19, pp.300~302 (1984)
  15. MacLaren RE, "Biometry and formula accuracy with intraocular lenses used for cataract surgery in extreme hyperopia", Am J Ophthalmol, 143, pp.920~931 (2007)
  16. Narvaez J, "Accuracy of intraocular lens power prediction using the Hoffer Q, Holladay 1, Holladay 2, and SRK", T formulas, 2006, pp.32, 2050~2053
  17. 맹효성, "전방깊이와 안축장에 따른 인공수정체 삽입 후 굴절 오차의 경향", 대한안과학회지, 51(2), pp.195~202 (2010), 대한안과학회
  18. Yang F, "Analysis of refractive status after cataract surgery in age-related cataract patients with shallow anterior chamber", Zhonghua Yan Ke Za Zhi, 50, pp.84~88 (2014)
  19. Gross FJ, "Increased prevalence of occludable angles and angle-closure glaucoma in patients with pseudoexfoliation", Am J Ophthalmol, 117, pp.333~336 (1994)
  20. Salmon JF, "The dimensions of eyes with chronic angle-closure Glaucoma", J Glaucoma, 3, pp.237~243 (1994)
  21. Marchini G, "Ultrasound biomicroscopic and conventional ultrasonographic study of ocular dimensions in primary angle-closure glaucoma", Ophthalmology, 105, pp.2091~2098 (1998)
  22. 강성용, "Inaccuracy of Intraocular Lens Power Prediction for Cataract Surgery in Angle-Closure Glaucoma", Yonsei Medical Journal, 50(2), pp.206~210 (2009), 연세대학교의과대학
  23. Hirnschall N, "Predicting the postoperative intraocular lens position using continuous intraoperative optical coherence tomography measurements", Invest Ophthalmol Vis Sci, 54, pp.5196~5203 (2013)
  24. Tehrani M, "Comparison of biometric measurements using partial coherence interferometry and applanation ultrasound", J Cataract Refract Surg, 29, pp.747~752 (2003)
  25. Giers U, "Comparison of A-scan device accuracy", J Cataract Refract Surg, 16, pp.235~242 (1990)
  26. Binkhorst RD, "The accuracy of ultrasonic measurement of the axial length of the eye", Ophthalmic Surg, 12, pp.363~365 (1981)

관련 논문AI추천

이 간행물의 다른 논문 (13건)