The Effect of Axial Length on the Variability of Stratus Optical Coherence Tomography
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose: To evaluate the effect of axial length on the variability of retinal nerve fiber layer (RNFL) thickness measurements using the Stratus optical coherence tomography (OCT) in normal and glaucomatous eyes. Methods: We measured the RNFL thickness in 474 subjects using the Stratus OCT twice during the same day. Axial length was measured with the IOLMaster, and refractive error was the absolute value of the spherical equivalent measured with an auto ref-keratometer. Standard deviation in overall mean RNFL thickness was used as the dependent variable to identify significant correlations. Results: Long axial length affected the variability in the RNFL thickness value by stratus OCT at the temporal quadrant (p = 0.006) and clock-hour sector 9 (p = 0.001). Refractive error also affected the variability of the RNFL thickness value by stratus OCT at the temporal quadrant (p = 0.025) and clock-hour sector 9 (p = 0.024). Conclusions: It is clinically significant that longer axial length demonstrates greater variability in temporal area as detected by OCT, a measurement which correlates with the preferably damaged position in the myopic glaucoma eye.
Abstract
Purpose: To evaluate the effect of axial length on the variability of retinal nerve fiber layer (RNFL) thickness measurements using the Stratus optical coherence tomography (OCT) in normal and glaucomatous eyes. Methods: We measured the RNFL thickness in 474 subjects using the Stratus OCT twice during the same day. Axial length was measured with the IOLMaster, and refractive error was the absolute value of the spherical equivalent measured with an auto ref-keratometer. Standard deviation in overall mean RNFL thickness was used as the dependent variable to identify significant correlations. Results: Long axial length affected the variability in the RNFL thickness value by stratus OCT at the temporal quadrant (p = 0.006) and clock-hour sector 9 (p = 0.001). Refractive error also affected the variability of the RNFL thickness value by stratus OCT at the temporal quadrant (p = 0.025) and clock-hour sector 9 (p = 0.024). Conclusions: It is clinically significant that longer axial length demonstrates greater variability in temporal area as detected by OCT, a measurement which correlates with the preferably damaged position in the myopic glaucoma eye.
참고문헌 (22)
- Vizzeri G, "Agreement between spectral-domain and time-domain OCT for measuring RNFL thickness", Br J Ophthalmol, 93, pp.775~781 (2009)
- Seet B, "Myopia in Singapore: taking a public health approach", Br J Ophthalmol, 85, pp.521~526 (2001)
- Lin LL, "Epidemiologic study of the prevalence and severity of myopia among schoolchildren in Taiwan in 2000", J Formos Med Assoc, 100, pp.684~691 (2001)
- Suzuki Y, "Risk factors for open-angle glaucoma in a Japanese population: the Tajimi Study", Ophthalmology, 113, pp.1613~1617 (2006)
- Perkins ES, "Open angle glaucoma, ocular hypertension, low-tension glaucoma, and refraction", Arch Ophthalmol, 100, pp.1464~1467 (1982)
- Grodum K, "Refractive error and glaucoma", Acta Ophthalmol Scand, 79, pp.560~566 (2001)
- Fong DS, "Glaucoma and myopia: are they related?", Int Ophthalmol Clin, 30, pp.215~218 (1990)
- Seddon JM, "Case-control study of ocular hypertension", Arch Ophthalmol, 101, pp.891~894 (1983)
- Leung CK, "Comparison of macular and peripapillary measurements for the detection of glaucoma: an optical coherence tomography study", Ophthalmology, 112, pp.391~400 (2005)
- Hoffmann EM, "Relationship between patterns of visual field loss and retinal nerve fiber layer thickness measurements", Am J Ophthalmol, 141, pp.463~471 (2006)
- Leung CK, "Retinal nerve fiber layer measurements in myopia: an optical coherence tomography study", Invest Ophthalmol Vis Sci, 47, pp.5171~5176 (2006)
- Choi SW, "Thickness changes in the fovea and peripapillary retinal nerve fiber layer depend on the degree of myopia", Korean J Ophthalmol, 20, pp.215~219 (2006)
- Hoh ST, "Peripapillary retinal nerve fiber layer thickness variations with myopia", Ophthalmology, 113, pp.773~777 (2006)
- Budenz DL, "Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes", Invest Ophthalmol Vis Sci, 46, pp.2440~2443 (2005)
- Budenz DL, "Reproducibility of peripapillary retinal nerve fiber thickness measurements with stratus OCT in glaucomatous eyes", Ophthalmology, 115, pp.661~666 (2008)
- Mayama C, "Myopia and advanced-stage open-angle glaucoma", Ophthalmology, 109, pp.2072~2077 (2002)
- Araie M, "Influence of myopic refraction on visual field defects in normal tension and primary open angle glaucoma", Jpn J Ophthalmol, 39, pp.60~64 (1995)
- Greve EL, "Myopia and glaucoma", Albrecht Von Graefes Arch Klin Exp Ophthalmol, 213, pp.33~41 (1980)
- Park SH, "Relation between axial length and ocular parameters", Ophthalmologica, 224, pp.188~193 (2010)
- Ray R, "Evaluation of image artifact produced by optical coherence tomography of retinal pathology", Am J Ophthalmol, 139, pp.18~29 (2005)
- El-Ashry M, "The effect of phacoemulsification cataract surgery on the measurement of retinal nerve fiber layer thickness using optical coherence tomography", Curr Eye Res, 31, pp.409~413 (2006)
- Youm DJ, "The effect of soft contact lenses during the measurement of retinal nerve fiber layer thickness using optical coherence tomography", Curr Eye Res, 34, pp.78~83 (2009)