Purpose: To determine the lowest limit of signal strength that is still effective for accurate analysis of optic coherence tomography (OCT) values, we investigated the reproducibility of OCT scans by signal strength (SS). Methods: A total of 668 subjects were scanned for measurements of retinal nerve fiber layer (RNFL) thickness using the Stratus OCT twice on the same day. The variability of overall RNFL thickness parameters obtained at different SS was analyzed and compared by repeated-measures of ANOVA and Spearman’s correlation coefficient. Values of the intraclass correlation coefficient (ICC) and variability (standard deviation) of RNFL thickness were obtained. The false positive ratio was analyzed. Results: When SS was 3, the variability of RNFL thickness was significantly different (low ICC, high variability)in comparison to when SS was 4 or greater. Significant negative correlations were observed between variability in RNFL thickness and signal strength. The difference of variability of average RNFL thickness between SS 4 (4.94 μm) and SS 6 (4.41 μm) was 0.53 μm. Conclusions: Clinically, the difference of variability of average RNFL thickness between SS 4 and SS 6 was quite small. High SS is important, however, when signal strength is low due to uncorrectable factors in patients in need of OCT for glaucoma and retinal disease. Our results suggest that SS 4 is the lowest acceptable limit of signal strength for obtaining reproducible scanning images.

Abstract

Purpose: To determine the lowest limit of signal strength that is still effective for accurate analysis of optic coherence tomography (OCT) values, we investigated the reproducibility of OCT scans by signal strength (SS). Methods: A total of 668 subjects were scanned for measurements of retinal nerve fiber layer (RNFL) thickness using the Stratus OCT twice on the same day. The variability of overall RNFL thickness parameters obtained at different SS was analyzed and compared by repeated-measures of ANOVA and Spearman’s correlation coefficient. Values of the intraclass correlation coefficient (ICC) and variability (standard deviation) of RNFL thickness were obtained. The false positive ratio was analyzed. Results: When SS was 3, the variability of RNFL thickness was significantly different (low ICC, high variability)in comparison to when SS was 4 or greater. Significant negative correlations were observed between variability in RNFL thickness and signal strength. The difference of variability of average RNFL thickness between SS 4 (4.94 μm) and SS 6 (4.41 μm) was 0.53 μm. Conclusions: Clinically, the difference of variability of average RNFL thickness between SS 4 and SS 6 was quite small. High SS is important, however, when signal strength is low due to uncorrectable factors in patients in need of OCT for glaucoma and retinal disease. Our results suggest that SS 4 is the lowest acceptable limit of signal strength for obtaining reproducible scanning images.

참고문헌 (28)

  1. Larsson E, "Retinal nerve fibre layerthickness in full-term children assessed with Heidelbergretinal tomography and optical coherence tomography:normal values and interocular asymmetry", Acta Ophthalmol, 89, pp.151~158 (2011)
  2. Patel PJ, "Intersession repeatabilityof optical coherence tomography measures of retinalthickness in early age-related macular degeneration", ActaOphthalmol, 89, pp.229~234 (2011)
  3. Eriksson U, "Repeatability in and interchangeabilitybetween the macular and the fast macular thickness mapprotocols: a study on normal eyes with Stratus optical coherencetomography", Acta Ophthalmol, 87, pp.725~730 (2009)
  4. Stein DM, "A new qualityassessment parameter for optical coherence tomography", Br J Ophthalmol, 90, pp.186~190 (2006)
  5. Ray R, "Evaluation of image artifactproduced by optical coherence tomography of retinal pathology", Am J Ophthalmol, 139, pp.18~29 (2005)
  6. El-Ashry M, "Theeffect of phacoemulsification cataract surgery on the measurementof retinal nerve fiber layer thickness using opticalcoherence tomography", Curr Eye Res, 31, pp.409~413 (2006)
  7. Savini G, "Influence of pupil size andcataract on retinal nerve fiber layer thickness measurementsby Stratus OCT", J Glaucoma, 15, pp.336~340
  8. Cheung CY, "Relationship betweenretinal nerve fiber layer measurement and signalstrength in optical coherence tomography", Ophthalmology, 115, pp.1347~1351 (2008)
  9. Youm DJ, "The effect of softcontact lenses during the measurement of retinal nervefiber layer thickness using optical coherence tomography", Curr Eye Res, 34, pp.78~83 (2009)
  10. Helb HM, "Clinicalevaluation of simultaneous confocal scanning laserophthalmoscopy imaging combined with high-resolution,spectral-domain optical coherence tomography", Acta Ophthalmol, 88, pp.842~849 (2010)
  11. Li S, "Evaluation of optic nerve headand retinal nerve fiber layer in early and advance glaucomausing frequency-domain optical coherence tomography", Graefes Arch Clin Exp Ophthalmol, 248, pp.429~434 (2010)
  12. Gordon MO, "The Ocular HypertensionTreatment Study: baseline factors that predictthe onset of primary open-angle glaucoma", Arch Ophthalmol, 120, pp.714~720 (2002)
  13. Katsanos A, "The relationshipbetween Rarebit perimetry and OCT-derived retinalnerve fibre layer thickness in glaucoma", Acta Ophthalmol, 86, pp.871~876 (2008)
  14. Iester M, "Optic nervehead and retinal nerve fibre analysis", pp.121~149 (2005), EditriceDogma
  15. Hougaard JL, "Glaucomatous retinalnerve fibre layer defects may be identified in Stratus OCTimages classified as normal", Acta Ophthalmol, 86, pp.569~575 (2008)
  16. Teikari JM, "Epidemiologic data on adult glaucomas.Data from the hospital discharge registry and theregistry of right to free medication", Acta Ophthalmol (Copenh), 67, pp.184~191 (1989)
  17. Tsai JC, "Optical coherence tomography measurement ofretinal nerve fiber layer after acute primary angle closurewith normal visual field", Am J Ophthalmol, 141, pp.970~972 (2006)
  18. DeLeon Ortega JE, "Effect ofglaucomatous damage on repeatability of confocal scanninglaser ophthalmoscope, scanning laser polarimetry, andoptical coherence tomography", Invest Ophthalmol Vis Sci, 48, pp.1156~1163 (2007)
  19. Huynh SC, "Peripapillaryretinal nerve fiber layer thickness in a population of6-year-old children: findings by optical coherence tomography", Ophthalmology, 113, pp.1583~1592 (2006)
  20. Repka MX, "Retinal nervefiber layer thickness in amblyopic eyes", Am J Ophthalmol, 148, pp.143~147 (2009)
  21. Salchow DJ, "Retinal nervefiber layer thickness in normal children measured with opticalcoherence tomography", Ophthalmology, 113, pp.786~791 (2006)
  22. Yu S, "Scanning laser polarimetrywith variable corneal compensation and opticalcoherence tomography in tilted disk", Am J Ophthalmol, 142, pp.475~482 (2006)
  23. Huang ML, "Rule extraction for glaucomadetection with summary data from Stratus OCT", InvestOphthalmol Vis Sci, 48, pp.244~250 (2007)
  24. Fisher JB, "Relation of visualfunction to retinal nerve fiber layer thickness in multiplesclerosis", Ophthalmology, 113, pp.324~332 (2006)
  25. Shah NN, "Combining structuraland functional testing for detection of glaucoma", Ophthalmology, 113, pp.1593~1602 (2006)
  26. Kim TW, "Retinal nerve fiberlayer damage as assessed by optical coherence tomographyin eyes with a visual field defect detected by frequencydoubling technology perimetry but not by standard automatedperimetry", Ophthalmology, 114, pp.1053~1057 (2007)
  27. Wu Z, "Signal strength isan important determinant of accuracy of nerve fiber layerthickness measurement by optical coherence tomography", JGlaucoma, 18, pp.213~216 (2009)
  28. Wu Z, "Factors associated withvariability in retinal nerve fiber layer thickness measurementsobtained by optical coherence tomography", Ophthalmology, 114, pp.1505~1512 (2007)

관련 논문AI추천

이 간행물의 다른 논문 (15건)