본문 바로가기
KERD
논문KCI 등재

Posterior Corneal Curvature Assessment after Epi-LASIK for Myopia: Comparison of Orbscan Ⅱ and Pentacam Imaging

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류안과학

초록

Purpose: To compare the changes in posterior corneal curvature using scanning slit topography (Orbscan II) and Scheimpflug imaging (Pentacam) before and after Epi-laser in situ keratomileusis (LASIK) for myopia. Methods: In a prospective observational case-series study, 20 myopic patients having undergone Epi-LASIK were examined serially with two different devices, Orbscan II and Pentacam, preoperatively and one month postoperatively. Posterior central elevation (PCE) and posterior maximal elevation (PME) were compared between the two devices, and the changes in parameters after Epi-LASIK were analyzed using a difference map. Results: All parameters (preoperative and postoperative PCE and preoperative and postoperative PME) that were measured using the Orbscan II were significantly greater compared to those of the Pentacam (for all p < 0.001). PCE and PME were significantly increased one month postoperatively in the Orbscan II measurements (p < 0.05) but were not significantly increased in the Pentacam measurements. Also, ΔPCE and ΔPME, in the difference map obtained by each serial scanning, were significantly greater in the Orbscan II measurements than with the Pentacam (p = 0.012, p = 0.016). Conclusions: The Pentacam measurements displayed significantly reduced values in all parameters related to posterior corneal elevation compared to those of the Orbscan II. The Pentacam showed no significant change in posterior corneal curvature after Epi-LASIK, based on the difference map.

Abstract

Purpose: To compare the changes in posterior corneal curvature using scanning slit topography (Orbscan II) and Scheimpflug imaging (Pentacam) before and after Epi-laser in situ keratomileusis (LASIK) for myopia. Methods: In a prospective observational case-series study, 20 myopic patients having undergone Epi-LASIK were examined serially with two different devices, Orbscan II and Pentacam, preoperatively and one month postoperatively. Posterior central elevation (PCE) and posterior maximal elevation (PME) were compared between the two devices, and the changes in parameters after Epi-LASIK were analyzed using a difference map. Results: All parameters (preoperative and postoperative PCE and preoperative and postoperative PME) that were measured using the Orbscan II were significantly greater compared to those of the Pentacam (for all p < 0.001). PCE and PME were significantly increased one month postoperatively in the Orbscan II measurements (p < 0.05) but were not significantly increased in the Pentacam measurements. Also, ΔPCE and ΔPME, in the difference map obtained by each serial scanning, were significantly greater in the Orbscan II measurements than with the Pentacam (p = 0.012, p = 0.016). Conclusions: The Pentacam measurements displayed significantly reduced values in all parameters related to posterior corneal elevation compared to those of the Orbscan II. The Pentacam showed no significant change in posterior corneal curvature after Epi-LASIK, based on the difference map.

참고문헌 (24)

  1. Wang Z, "Posterior corneal surface topographic changes after laser in situ keratomileusis are related to residual corneal bed thickness", Ophthalmology, 106, pp.406~409 (1999)
  2. Kamiya K, "Influence of excimer laser photorefractive keratectomy on the posterior corneal surface", J Cataract Refract Surg, 26, pp.867~871 (2000)
  3. Baek T, "Factors affecting the forward shift of posterior corneal surface after laser in situ keratomileusis", Ophthalmology, 108, pp.317~320 (2001)
  4. Seitz B, "Posterior corneal curvature changes after myopic laser in situ keratomileusis", Ophthalmology, 108, pp.666~672 (2001)
  5. Hernandez-Quintela E, "Posterior corneal surface changes after refractive surgery", Ophthalmology, 108, pp.1415~1422 (2001)
  6. Sharma N, "Posterior corneal topographic changes after partial flap during laser in situ keratomileusis", Br J Ophthalmol, 87, pp.160~162 (2003)
  7. Lee DH, "Early spatial changes in the posterior corneal surface after laser in situ keratomileusis", J Cataract Refract Surg, 29, pp.778~784 (2003)
  8. Yoshida T, "Difference map or single elevation map in the evaluation of corneal forward shift after LASIK", Ophthalmology, 110, pp.1926~1930 (2003)
  9. Miyata K, "Residual bed thickness and corneal forward shift after laser in situ keratomileusis", J Cataract Refract Surg, 30, pp.1067~1072 (2004)
  10. Twa MD, "Response of the posterior corneal surface to laser in situ keratomileusis for myopia", J Cataract Refract Surg, 31, pp.61~71 (2005)
  11. Grzybowski DM, "Model for nonectatic increase in posterior corneal elevation after ablative procedures", J Cataract Refract Surg, 31, pp.72~81 (2005)
  12. 김효진, "라식 후 유발된 각막돌출증의 임상 및 형태학적 소견", 대한안과학회지, 46(5), pp.910~914 (2005), 대한안과학회
  13. Cairns G, "Assessing the accuracy of Orbscan II post-LASIK: apparent keratectasia is paradoxically associated with anterior chamber depth reduction in successful procedures", Clin Experiment Ophthalmol, 33, pp.147~152 (2005)
  14. Ueda T, "Posterior corneal surface changes after hyperopic laser in situ keratomileusis", J Cataract Refract Surg, 31, pp.2084~2087 (2005)
  15. Ciolino JB, "Changes in the posterior cornea after laser in situ keratomileusis and photorefractive keratectomy", J Cataract Refract Surg, 32, pp.1426~1431 (2006)
  16. Hashemi H, "Corneal changes after laser refractive surgery for myopia: comparison of Orbscan II and Pentacam findings", J Cataract Refract Surg, 33, pp.841~847 (2007)
  17. Cairns G, "Orbscan computerized topography: attributes, applications, and limitations", J Cataract Refract Surg, 31, pp.205~220 (2005)
  18. Kopacz D, "Pentacam: the new way for anterior eye segment imaging and mapping", Klin Oczna, 107, pp.728~731 (2005)
  19. "Pentacam and Orbscan II Measurements of Posterior Corneal Elevation Before and After Photorefractive Keratectomy", Journal Of Refractive Surgery, 25, pp.290~295 (2009), SLACK INC
  20. Ormonde S, "Changes in the posterior corneal surface after LASIK", J Cataract Refract Surg, 30, pp.533~534 (2004)
  21. Nawa Y, "Evaluation of apparent ectasia of the posterior surface of the cornea after keratorefractive surgery", J Cataract Refract Surg, 31, pp.571~573 (2005)
  22. Maldonado MJ, "Repeatability and reproducibility of posterior corneal curvature measurements by combined scanning-slit and placido-disc topography after LASIK", Ophthalmology, 113, pp.1918~1926 (2006)
  23. Chen D, "Intrasession and intersession repeatability of the Pentacam system on posterior corneal assessment in the normal human eye", J Cataract Refract Surg, 33, pp.448~454 (2007)
  24. Miyata K, "Time course of changes in corneal forward shift after excimer laser photorefractive keratectomy", Arch Ophthalmol, 120, pp.896~900 (2002)

관련 논문AI추천

The Changes of Posterior Corneal Surface and High-Order Aberrations after Refractive Surgery in Moderate Myopia김미금, 위원량, 이상목, 이진학, 이현주, Min Joung Lee대한안과학회 · Korean Journal of Ophthalmology2007 · 제21권 제3호Comparison of Anterior, Posterior, and Total Corneal Astigmatism Measured Using a Single Scheimpflug Camera in Healthy and Keratoconus Eyes최영, 김효명, 송종석, 엄영섭대한안과학회 · Korean Journal of Ophthalmology2018 · 제32권 제3호정상안과 펨토초레이저 라식수술안에서 서로 다른 4가지 각막두께 측정계들의 중심각막두께 비교김진형, 박세훈, 이도형, 최석규대한안과학회 · 대한안과학회지2010 · 제51권 제3호Comparison of Laser In Situ Keratomileusis Flap Morphology and Predictability by WaveLight FS200 Femtosecond Laser and Moria Microkeratome: An Anterior Segment Optical Coherence Tomography StudyMahmoud A. Abdelsalam, Mohamed A. Nassr, Mohamed S. Hussein, Zeiad H. Eldaly대한안과학회 · Korean Journal of Ophthalmology2019 · 제33권 제2호Factors Influencing Corneal Flap Thickness in Laser In Situ Keratomileusis with a Femtosecond Laser정소향, 주천기, Chan Young Kim, Ji Hye Song, Kyoung Sun Na대한안과학회 · Korean Journal of Ophthalmology2011 · 제25권 제1호Agreement between Scheimpflug Camera and the Swept-source Optical Coherence Tomography Measurements in Keratometry and Higher-order Aberrations김유진, 전루민, 한경은대한안과학회 · Korean Journal of Ophthalmology2021 · 제35권 제5호

이 간행물의 다른 논문 (14건)