Clinical Efficacy of Custom-built Software for the Early Detection of Glaucoma: A Comparison of Axial-length and Major Retinal Artery Location Data

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류안과학

초록

Purpose: To assess the clinical efficacy for early detection of glaucoma using custom-built image softwarevisualizing translucent retinal nerve fiber layer thickness (RNFLT) that is graphed based on a normative database. Methods: This prospective study was conducted using a normative database constructed with RNFLT data of151 healthy Korean eyes. The reference lines of the mean, the lower 5%, and the lower 1% limit were visualizedas a translucent RNFLT graph produced by our software after inputting each subject’s major retinal arteryposition and overlaying the results onto the RNFLT measurements. Fifty-eight additional healthy controland 79 early-glaucoma eyes were collected for the validation group. If a subject’s RNFLT graph was outsidethe reference line of the lower 1% limit, the graph was defined as abnormal. The lower 1% limit, which wasgenerated by three criteria (criterion 1, built-in software; criterion 2, axial-length data; criterion 3, major retinalartery data), was used to address the difference of agreement with a standard answer. Results: For criteria 1, 2, and 3, the accuracy of our custom-built software was significantly higher than thatof the manufacturer’s database (kappa of 0.475 vs. 0.852 vs. 0.940; sensitivity of 62.0% vs. 91.1% vs. 97.5%,respectively) maintaining high specificity (87.9% vs. 94.8% vs. 96.6%, respectively). Conclusions: The custom-built imaging software with the constructed RNFLT normative database showedhigh clinical efficiency for early detection of glaucoma with negligible user-related variability.

Abstract

Purpose: To assess the clinical efficacy for early detection of glaucoma using custom-built image softwarevisualizing translucent retinal nerve fiber layer thickness (RNFLT) that is graphed based on a normative database. Methods: This prospective study was conducted using a normative database constructed with RNFLT data of151 healthy Korean eyes. The reference lines of the mean, the lower 5%, and the lower 1% limit were visualizedas a translucent RNFLT graph produced by our software after inputting each subject’s major retinal arteryposition and overlaying the results onto the RNFLT measurements. Fifty-eight additional healthy controland 79 early-glaucoma eyes were collected for the validation group. If a subject’s RNFLT graph was outsidethe reference line of the lower 1% limit, the graph was defined as abnormal. The lower 1% limit, which wasgenerated by three criteria (criterion 1, built-in software; criterion 2, axial-length data; criterion 3, major retinalartery data), was used to address the difference of agreement with a standard answer. Results: For criteria 1, 2, and 3, the accuracy of our custom-built software was significantly higher than thatof the manufacturer’s database (kappa of 0.475 vs. 0.852 vs. 0.940; sensitivity of 62.0% vs. 91.1% vs. 97.5%,respectively) maintaining high specificity (87.9% vs. 94.8% vs. 96.6%, respectively). Conclusions: The custom-built imaging software with the constructed RNFLT normative database showedhigh clinical efficiency for early detection of glaucoma with negligible user-related variability.

참고문헌 (14)

  1. Freeman EE, "Glaucoma and quality of life : the Salisbury Eye Evaluation", Ophthalmology, 115, pp.233~238 (2008)
  2. Heijl A, "The times they are a-changin' : time to change glaucoma management", Acta Ophthalmol, 91, pp.92~99 (2013)
  3. Budenz DL, "Sensitivity and specificity of the StratusOCT for perimetric glaucoma", Ophthalmology, 112, pp.3~9 (2005)
  4. Hood DC, "Improving our understanding, and detection, of glaucomatous damage : an approach based upon optical coherence tomography(OCT)", Prog Retin Eye Res, 57, pp.46~75 (2017)
  5. Rho S, "Improvement of diagnostic performance regarding retinal nerve fiber layer defect using shifting of the normative database according to vessel position", Invest Ophthalmol Vis Sci, 55, pp.5116~5124 (2014)
  6. Budenz DL, "Atlas of visual fields", pp.143~145 (1997), Lippincott-Raven
  7. Sim J, "The kappa statistic in reliability studies : use, interpretation, and sample size requirements", Phys Ther, 85, pp.257~268 (2005)
  8. Wang M, "Quantifying positional variation of retinal blood vessels in glaucoma", PLoS One, 13, pp.e0193555~ (2018)
  9. Forsman E, "Lifetime visual disability in open-angle glaucoma and ocular hypertension", J Glaucoma, 16, pp.313~319 (2007)
  10. Grodum K, "A comparison of glaucoma patients identified through mass screening and in routine clinical practice", Acta Ophthalmol Scand, 80, pp.627~631 (2002)
  11. Kang SH, "Korean normative database for time domain optical coherence tomography to detect localized retinal nerve fiber layer defects(preliminary study)", Jpn J Ophthalmol, 54, pp.144~150 (2010)
  12. Hood DC, "Blood vessel contributions to retinal nerve fiber layer thickness profiles measured with optical coherence tomography", J Glaucoma, 17, pp.519~528 (2008)
  13. Hood DC, "The location of the inferior and superior temporal blood vessels and interindividual variability of the retinal nerve fiber layer thickness", J Glaucoma, 19, pp.158~166 (2010)
  14. Leung CK, "Retinal nerve fiber layer imaging with spectral-domain optical coherence tomography a study on diagnostic agreement with Heidelberg Retinal Tomograph", Ophthalmology, 117, pp.267~274 (2010)

관련 논문AI추천

이 간행물의 다른 논문 (14건)