본문 바로가기
KERD
논문KCI 등재

Repeatability of Corneal Epithelial Thickness Map Using Anterior- Segment Optical Coherence Tomography in Normal and Corneal Disease Patients

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류안과학

초록

Purpose: To evaluate the repeatability of corneal epithelial thickness (CET) measurements in normal eyes and eyes diagnosed with corneal disease using the epithelial thickness map (ETM) of anterior-segment optical coherence tomography (OCT). Methods: In this retrospective study, patients with three OCT scans using the ETM mode of Cirrus OCT between October 2021 and January 2024 were reviewed. Two groups of subjects were included: (1) normal subjects with no history of ophthalmic surgery, corneal diseases, and topical antiglaucoma medication uses; and (2) subjects with corneal diseases including dry eye syndrome, recurrent corneal erosion, pterygium, and others. A total of 57 eyes of 57 normal subjects and 106 eyes of 76 patients with corneal disease were included. ETM was analyzed in 25 zones (one zone within 0–2 mm diameter, eight zones within 2–5 mm diameter, eight zones within 5–7 mm diameter, and eight zones within 7–9 mm diameter). Repeatability was evaluated by calculating intraclass correlation coefficient (ICC), coefficient of variation (CoV), within-subject standard deviation (Sw), and Bland-Altman plot. Results: Among a total of 25 sectors, the normal eyes showed high repeatability (ICC, >0.75; CoV, 2.160%–5.292%; Sw, 0.760– 1.653 μm) in 23 sectors, and corneal diseases patients also showed high repeatability (ICC, >0.75; CoV, 4.167%–9.606%; Sw, 1.298–3.340 μm) in 22 sectors. However, the wide range of 95% limit of agreement width of Bland-Altman plot presented in corneal disease group and some peripheral zones in normal eyes indicates some variability of CET measurements. Conclusions: Except for a few peripheral sectors, ETM of Cirrus OCT provides repeatable CET measurements in normal eyes; however in corneal disease group, repeatability was not consistently high. To measure CET accurately, performing multiple measurements is advised especially in patients with corneal disease and patients in whom peripheral CET values.

Abstract

Purpose: To evaluate the repeatability of corneal epithelial thickness (CET) measurements in normal eyes and eyes diagnosed with corneal disease using the epithelial thickness map (ETM) of anterior-segment optical coherence tomography (OCT). Methods: In this retrospective study, patients with three OCT scans using the ETM mode of Cirrus OCT between October 2021 and January 2024 were reviewed. Two groups of subjects were included: (1) normal subjects with no history of ophthalmic surgery, corneal diseases, and topical antiglaucoma medication uses; and (2) subjects with corneal diseases including dry eye syndrome, recurrent corneal erosion, pterygium, and others. A total of 57 eyes of 57 normal subjects and 106 eyes of 76 patients with corneal disease were included. ETM was analyzed in 25 zones (one zone within 0–2 mm diameter, eight zones within 2–5 mm diameter, eight zones within 5–7 mm diameter, and eight zones within 7–9 mm diameter). Repeatability was evaluated by calculating intraclass correlation coefficient (ICC), coefficient of variation (CoV), within-subject standard deviation (Sw), and Bland-Altman plot. Results: Among a total of 25 sectors, the normal eyes showed high repeatability (ICC, >0.75; CoV, 2.160%–5.292%; Sw, 0.760– 1.653 μm) in 23 sectors, and corneal diseases patients also showed high repeatability (ICC, >0.75; CoV, 4.167%–9.606%; Sw, 1.298–3.340 μm) in 22 sectors. However, the wide range of 95% limit of agreement width of Bland-Altman plot presented in corneal disease group and some peripheral zones in normal eyes indicates some variability of CET measurements. Conclusions: Except for a few peripheral sectors, ETM of Cirrus OCT provides repeatable CET measurements in normal eyes; however in corneal disease group, repeatability was not consistently high. To measure CET accurately, performing multiple measurements is advised especially in patients with corneal disease and patients in whom peripheral CET values.

참고문헌 (30)

  1. Samy MM, "Age-and sex-related differences in corneal epithelial thickness measured with spectral domain anterior segment optical coherence tomography among Egyptians", Medicine(Baltimore), 96, pp.e8314~ (2017)
  2. Kim BJ, "Age-related differences in corneal epithelial thickness measurements with anterior segment optical coherence tomography", Jpn J Ophthalmol, 60, pp.357~364 (2016)
  3. Yang Y, "Age-related changes in human corneal epithelial thickness measured with anterior segment optical coherence tomography", Invest Ophthalmol Vis Sci, 55, pp.5032~5038 (2014)
  4. Sella R, "Repeatability and reproducibility of corneal epithelial thickness mapping with spectral-domain optical coherence tomography in normal and diseased cornea eyes", Am J Ophthalmol, 197, pp.88~97 (2019)
  5. Nam M, "Changes in corneal epithelial thickness induced by topical antiglaucoma medications", J Clin Med, 10, pp.3464~ (2021)
  6. Kanellopoulos AJ, "In vivo 3-dimensional corneal epithelial thickness mapping as an indicator of dry eye : preliminary clinical assessment", Am J Ophthalmol, 157, pp.63~68 (2014)
  7. Kanellopoulos AJ, "Correlation between epithelial thickness in normal corneas, untreated ectatic corneas, and ectatic corneas previously treated with CXL; is overall epithelial thickness a very early ectasia prognostic factor?", Clin Ophthalmol, 6, pp.789~800 (2012)
  8. Le Q, "Measurement of corneal and limbal epithelial thickness by anterior segment optical coherence tomography and in vivo confocal microscopy", BMC Ophthalmol, 16, pp.163~ (2016)
  9. Kanellopoulos AJ, "Comparison of high-resolution Scheimpflug and high-frequency ultrasound biomicroscopy to anterior-segment OCT corneal thickness measurements", Clin Ophthalmol, 7, pp.2239~2247 (2013)
  10. Kanellopoulos AJ, "Anterior segment optical coherence tomography : assisted topographic corneal epithelial thickness distribution imaging of a keratoconus patient", Case Rep Ophthalmol, 4, pp.74~78 (2013)
  11. Feng Y, "Epithelial thickness mapping in keratoconic corneas: repeatability and agreement between CSO MS-39, Heidelberg Anterion, and Optovue Avanti OCT devices", J Refract Surg, 39, pp.474~480 (2023)
  12. Levy A, "Corneal epithelial thickness mapping in the diagnosis of ocular surface disorders involving the corneal epithelium : a comparative study", Cornea, 41, pp.1353~1361 (2022)
  13. Ma XJ, "Repeatability of corneal epithelial thickness measurements using Fourier-domain optical coherence tomography in normal and post-LASIK eyes", Cornea, 32, pp.1544~1548 (2013)
  14. Hashmani N, "Wide corneal epithelial mapping using an optical coherence tomography", Invest Ophthalmol Vis Sci, 59, pp.1652~1658 (2018)
  15. Salman A, "Diagnostic accuracy of corneal and epithelial thickness map parameters to detect keratoconus and suspect keratoconus", J Ophthalmol, 2023, pp.6677932~ (2023)
  16. Kanellopoulos AJ, "In vivo three-dimensional corneal epithelium imaging in normal eyes by anterior-segment optical coherence tomography : a clinical reference study", Cornea, 32, pp.1493~1498 (2013)
  17. Hashmani N, "The influence of tomographic corneal characteristics on epithelial thickness profile", Cureus, 12, pp.e11731~ (2020)
  18. Sikorski BL, "Simultaneous corneal topography and epithelial thickness mapping from a single measurement using optical coherence tomography", J Ophthalmol, 2022, pp.7339306~ (2022)
  19. Reinstein DZ, "Comparison of corneal epithelial thickness measurement between Fourier-domain OCT and very high-frequency digital ultrasound", J Refract Surg, 31, pp.438~445 (2015)
  20. Loureiro T, "Corneal epithelial thickness changes after topical treatment of dry eye disease in primary Sjogren syndrome", Clin Ophthalmol, 17, pp.993~1005 (2023)
  21. Abtahi MA, "Corneal epithelial thickness mapping : a major review", J Ophthalmol, 2024, pp.6674747~ (2024)
  22. Asroui L, "Determining the utility of epithelial thickness mapping in refractive surgery evaluations", Am J Ophthalmol, 240, pp.125~134 (2022)
  23. Lin K, "Comparison of the repeatability and reproducibility of corneal thickness mapping using optical coherence tomography according to tear film breakup time", BMC Ophthalmol, 24, pp.275~ (2024)
  24. Vega-Estrada A, "Corneal epithelial thickness intrasubject repeatability and its relation with visual limitation in keratoconus", Am J Ophthalmol, 200, pp.255~262 (2019)
  25. Li Y, "Repeatability of corneal and epithelial thickness measurements with anterior segment optical coherence tomography in keratoconus", PLoS One, 16, pp.e0248350~ (2021)
  26. Mohr N, "Pellucid marginal degeneration versus keratoconus : distinction with wide-field SD-OCT corneal sublayer pachymetry", Br J Ophthalmol, 105, pp.1638~1644 (2021)
  27. Lu NJ, "Repeatability of cornea and sublayer thickness measurements using optical coherence tomography in corneas of anomalous refractive status", J Refract Surg, 35, pp.600~605 (2019)
  28. Li Y, "Corneal epithelial thickness mapping by Fourier-domain optical coherence tomography in normal and keratoconic eyes", Ophthalmology, 119, pp.2425~2433 (2012)
  29. Rocha KM, "SD-OCT analysis of regional epithelial thickness profiles in keratoconus, postoperative corneal ectasia, and normal eyes", J Refract Surg, 29, pp.173~179 (2013)
  30. Garhofer G, "The association between tear film thickness as measured with OCT and symptoms and signs of dry eye disease : a pooled analysis of 6 clinical trials", J Clin Med, 9, pp.3791~ (2020)

관련 논문AI추천

Anterior Ocular Biometrics Using Placido-scanning-slit System, Rotating Scheimpflug Tomography, and Swept-source Optical Coherence Tomography김응권, 김태임, 류소영, 서경률, 윤숙현, 전익현대한안과학회 · Korean Journal of Ophthalmology2022 · 제36권 제3호Reliability of RTVue, Visante, and Slit-Lamp Adapted Ultrasonic Pachymetry for Central Corneal Thickness Measurement김응권, 김태임, 남상민, 서경률, 이상엽, 홍진표, Alessandro Meduri연세대학교의과대학 · Yonsei Medical Journal2012 · 제53권 제3호중심각막두께 측정에 대한 파장가변 빛간섭단층촬영계의 유용성서샘, 김임규, 이규원, 이종은, 이준석대한안과학회 · 대한안과학회지2016 · 제57권 제10호Agreement between Scheimpflug Camera and the Swept-source Optical Coherence Tomography Measurements in Keratometry and Higher-order Aberrations김유진, 전루민, 한경은대한안과학회 · Korean Journal of Ophthalmology2021 · 제35권 제5호두 가지 스펙트럼영역 빛간섭단층촬영기, 펜타캠, 초음파각막측정계로 측정한 중심각막두께 비교이보람, 전루민, 정유진, 한경은대한안과학회 · 대한안과학회지2016 · 제57권 제10호Anterior Segment Swept-Source Optical Coherence Tomography–based Assessment of Corneal Refractive Profiles in Stevens-Johnson Syndrome/Toxic Epidermal Necrolysis Patients: A Controlled Comparative StudyDong Hee Ha, Kyoung Woo Kim, Seung Hyeun Lee대한안과학회 · Korean Journal of Ophthalmology2025 · 제39권 제2호

이 간행물의 다른 논문 (12건)