Zirconia Abutment Fracture in the Anterior Region: Case Series
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
This case report examines the cause of zirconia abutment fracture in implant treatments. Two patients who experienced a fracture of a maxillary incisor received a titanium base implant with zirconia custom abutments. Fractures were observed at the cervical area of the connection of the titanium base and zirconia abutment. Six causes of fracture were analyzed for each of the two cases including manufacturing defects of zirconia blocks, thin sidewall thickness of zirconia, strong internal stress, implant angulation, concentration of excessive stress according to occlusal aspect, adhesion problem of titanium base, and zirconia abutment
Abstract
This case report examines the cause of zirconia abutment fracture in implant treatments. Two patients who experienced a fracture of a maxillary incisor received a titanium base implant with zirconia custom abutments. Fractures were observed at the cervical area of the connection of the titanium base and zirconia abutment. Six causes of fracture were analyzed for each of the two cases including manufacturing defects of zirconia blocks, thin sidewall thickness of zirconia, strong internal stress, implant angulation, concentration of excessive stress according to occlusal aspect, adhesion problem of titanium base, and zirconia abutment
참고문헌 (20)
- Pjetursson BE, "A systematic review of the survival and complication rates of implant supported fixed dental prostheses(FDPs)after a mean observation period of at least 5 years", Clin Oral Implants Res, 23(Suppl 6), pp.22~38 (2012)
- Jung RE, "Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow-up of 5 years", Clin Oral Implants Res, 23(Suppl 6), pp.2~21 (2012)
- Sailer I, "A systematic review of the performance of ceramic and metal implant abutments supporting fixed implant reconstructions", Clin Oral Implants Res, 20(Suppl 4), pp.4~31 (2009)
- Ferrari M, "Zirconia abutments and restorations : From laboratory to clinical investigations", Dent Mater, 31, pp.e63~e76 (2015)[DOI]
- Van Brakel R, "The effect of zirconia and titanium implant abutments on light reflection of the supporting soft tissues", Clin Oral Implants Res, 22, pp.1172~1178 (2011)
- Kelly JR, "Stabilized zirconia as a structural ceramic : An overview", Dent Mater, 24, pp.289~298 (2008)
- Denry I, "State of the art of zirconia for dental applications", Dent Mater, 24, pp.299~307 (2008)
- Aboushelib MN, "Zirconia implant abutment fracture : Clinical case reports and precautions for use", Int J Prosthodont, 22, pp.616~619 (2009)
- Ekfeldt A, "Zirconia abutments for single-tooth implant restorations : a retrospective and clinical follow-up study", Clin Oral Implants Res, 22, pp.1308~1314 (2011)
- Roe P, "Retrieval of a fractured zirconia implant abutment using a modified crown and bridge remover : A clinical report", J Prosthodont, 20, pp.315~318 (2011)
- Att W, "Fracture resistance of single-tooth implant-supported all-ceramic restorations : An in vitro study", J Prosthet Dent, 95, pp.111~116 (2006)
- Gehrke P, "In vitro fatigue and fracture resistance of one and two-piece CAD", CAM zirconia implant abutments, 2015, pp.30, 546~554
- Linkevicius T, "Retention of zirconia copings over smooth and airborne-particle-abraded titanium bases with different resin cements", J Prosthet Dent, 121, pp.949~954 (2019)
- Bottino MA, "Fracture of zirconia abutment with metallic insertion on anterior single titanium implant with internal hexagon : Retrieval analysis of a failure", Eur J Prosthodont Restor Dent, 24, pp.164~168 (2016)
- Martinez-Rus F, "Prosthodontic considerations in the implantsupported all-ceramic restoration of congenitally missing maxillary lateral incisor : A clinical report", J Prosthodont, 23, pp.232~235 (2014)
- Paolantoni G, "Findings of a four-year randomized controlled clinical trial comparing two-piece and one-piece zirconia abutments supporting single prosthetic restorations in maxillary anterior region", Biomed Res Int, 2016, pp.8767845~ (2016)
- Fabbri G, "Clinical evaluation of the influence of connection type and restoration height on the reliability of zirconia abutments : A retrospective study on 965 abutments with a mean 6-year follow-up", Int J Periodontics Restorative Dent, 37, pp.19~31 (2017)
- Att W, "Influence of Preparation and Wall Thickness on the Resistance to Fracture of Zirconia Implant Abutments", Clinical Implant Dentistry and Related Research, 14, pp.196~203 (2011)
- Thulasidas S, "Influence of Implant Angulation on the Fracture Resistance of Zirconia Abutments", J Prosthodont, 24, pp.127~135 (2015)
- Al Hamad KQ, "The effects of height and surface roughness of abutments and the type of cement on bond strength of cement-retained implant restorations", Clin Oral Implants Res, 22, pp.638~644 (2011)