An Experimental Comparative Study of Radiography, Ultrasonography and CT Imaging in the IV Catheter Fragmen

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류방사선과학

초록

The objective of this study was to detect the fragments generated during IV (intravenous) catheter injection of contrast medium and drug administration in a clinical setting and removal was performed by experimentally producing a phantom, and to compare the radiography, ultrasonography, and multi-detector computed tomography (MDCT) imaging and radiation dose. A 1 cm fragment of an 18 gage Teflon® IV catheter with saline was inserted into the IV control line. Radiography, CT, and ultrasonography were performed and radiography and CT dose were calculated. CT and ultrasonography showed an IV catheter fragment clinically and radiography showed no visible difference in the ability to provide a useful image of an IV catheter fragment modality (p >.05). Radiography of effective dose (0.2139 mSv·Gy-1·cm-2) form DAP DAP (0.93 μGy·m 2), and dose length product (DLP) (201 mGy·cm) to effective dose was calculated as 0.483 mSv. IV catheter fragment were detected of radiography, ultrasonography and CT. These results can be obtained by menas of an excellent IV catheter fragment of detection capability CT. However, CT is followed by radiation exposure. IV catheter fragment confirming the position and information recommend an ultrasonography.

Abstract

The objective of this study was to detect the fragments generated during IV (intravenous) catheter injection of contrast medium and drug administration in a clinical setting and removal was performed by experimentally producing a phantom, and to compare the radiography, ultrasonography, and multi-detector computed tomography (MDCT) imaging and radiation dose. A 1 cm fragment of an 18 gage Teflon® IV catheter with saline was inserted into the IV control line. Radiography, CT, and ultrasonography were performed and radiography and CT dose were calculated. CT and ultrasonography showed an IV catheter fragment clinically and radiography showed no visible difference in the ability to provide a useful image of an IV catheter fragment modality (p >.05). Radiography of effective dose (0.2139 mSv·Gy-1·cm-2) form DAP DAP (0.93 μGy·m 2), and dose length product (DLP) (201 mGy·cm) to effective dose was calculated as 0.483 mSv. IV catheter fragment were detected of radiography, ultrasonography and CT. These results can be obtained by menas of an excellent IV catheter fragment of detection capability CT. However, CT is followed by radiation exposure. IV catheter fragment confirming the position and information recommend an ultrasonography.

참고문헌 (18)

  1. Turner DP, "Accidental passage of polyethylene catheter from cubital vein to right atrium", N Eng J Med, 251, pp.744~ (1954)
  2. Denny MA, "Ventricular tachycardia secondary to port-a-cath fracture and embolization", J Emerg Med, 24(1), pp.29~34 (2003)
  3. 권대철, "AN IV CATHETER FRAGMENTS DURING MDCT SCANNING OF HUMAN ERROR: EXPERIMENTAL AND REPRODUCIBLE MICROSCOPIC MAGNIFICATION ANALYSIS", 방사선방어학회지, 36(4), pp.195~199 (2011), 대한방사선방어학회
  4. 권대철, "정맥내의 IV 카테터 조각의 3D MDCT 재구성 영상", 의학물리, 17(3), pp.167~172 (2006), 한국의학물리학회
  5. Benson LS, "Forearm compartment syndrome due to automated injection of computed tomography contrast material: Case report", J Orthop Trauma, 10, pp.433~436 (1996)
  6. 권대철, "전산화단층검사에서 조영제의 피하 정맥 혈관외유출 환자의 3D영상", 의학물리, 16(1), pp.47~51 (2005), 한국의학물리학회
  7. Shannon FL, "Venous bullet embolism: rationale for mandatory extraction", J Trauma, 27, pp.1118~1122 (1987)
  8. Hansson B, "Relationships Between Entrance Skin Dose, Effective Dose and Dose Area Product for Patients in Diagnostic and Interventional Cardiac Procedures", Radiat Pro Dosimetry, 90, pp.141~144 (2000)
  9. European Commission, "European guidelines on quality criteria for computed tomography", European Commission, ~ (2000)
  10. Gschwind CR, "The intravenous foreign body: A report of 2 cases", J Hand Surg, 27A, pp.350~354 (2002)
  11. Leunens G, "Human errors in data transfer during preparation and delivery of radiation treatment affecting the final result: garbage in, garbage out", Radiother Oncol, 23(4), pp.217~222 (1992)
  12. Gabelmann A, "Percutaneous retrieval of lost or misplaced intravascular objects", Am J Roentgenol, 176, pp.1509~1513 (2001)
  13. Vadlamani P, "Catheter fragments and embolization from totally implanted venous access ports", Angiology, 49, pp.1013~1016 (1998)
  14. Weiss CR, "Multidetector 3D CT of pulmonary embolism of a peripheral intravenous line", Emerg Radiol, 11, pp.247~249 (2005)
  15. 장근조, "정맥 내의 IV 카테터 조각을 3D MDCT 볼륨렌더링 영상으로 구현하기 위한 HU 임계치", 한국콘텐츠학회 논문지, 7(4), pp.206~212 (2007), 한국콘텐츠학회
  16. Gulcu N, "Detection of a retained epidural catheter fragment", Reg Anesth Pain Med, 31, pp.589~590 (2006)
  17. 이수영, "A Sheared Catheter Fragment in the Wrist after Arterial Cannulation Attempt-A Case Report-", The Korean Journal of Critical Care Medicine, 25(2), pp.118~121 (2010), 대한중환자의학회
  18. Aras MH, "Comparison of the sensitivity for detecting foreign bodies among conventional plain radiography, computed tomography and ultrasonography", Dentomaxillofac Rad, 39, pp.72~78 (2010)

관련 논문AI추천

잡견에서 조영제 혈관외유출 예방을 위한 스트레인 게이지기반의 EDA 시스템 성능 평가를 위한 실험적 연구권대철, 양성환, 유병규, 이종석, 조문선대한의용생체공학회 · 의공학회지2008 · 제29권 제1호Comparison of accuracy between panoramic radiography, cone-beam computed tomography, and ultrasonography in detection of foreign bodies in the maxillofacial region: an in vitro studyMaedeh Aminian, Mehrdad Abdinian, Samad Seyyedkhamesi대한구강악안면외과학회 · 대한구강악안면외과학회지2018 · 제44권 제1호저농도 조영제를 사용한 CT검사에서 저관전압 기법에 따른 유용성 평가정강교, 조평곤대한방사선과학회 · Journal of Radiological Science and Technology2016 · 제39권 제1호Image Evaluation and Exposure Dose with the Application of Tube Voltage and Adaptive Statistical Iterative Reconstruction of Low Dose Computed Tomography김기정, 문태준, 이혜남대한방사선과학회 · Journal of Radiological Science and Technology2017 · 제40권 제2호적외선 기반의 혈관외유출 검출시스템을 이용한 조영제의 혈관외유출 검출권대철, 장근조대한의용생체공학회 · 의공학회지2009 · 제30권 제5호Dose Distribution and Image Quality in the Gantry Aperture for CT Examinations김유현, 김장섭, 김형철, 신귀순, 신동철, 이기열, 이성현, 이준협, 조평곤, 최종학대한방사선과학회 · Journal of Radiological Science and Technology2009 · 제32권 제4호

이 간행물의 다른 논문 (15건)