Dose Distribution and Image Quality in the Gantry Aperture for CT Examinations

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류방사선과학

초록

The purpose of this study was to determine the dose distribution and image quality according to slice thickness and BC(beam collimation) in the gantry aperture. CT scans were performed with a 64-slice MDCT(Brilliance 64, Philips, Cleveland, USA) scanner. To determine the dose distribution according to BC, a ionization chamber was placed at isocenter and 5, 10, 15, 20, 25 and 30cm positions from the isocenter in the 12, 3, 6 and 9 o’clock directions. The dose distribution for phantom scan was also measured using CT head and body dose phantom with five holes at the center of the phantom and the positions of the 12, 3, 6 and 9 o’clock directions. The image noise measurement for different BCs was performed using an AAPM CT phantom. Water-filled block of the phantom was moved by 5cm or 10cm to the 12 o’clock direction, and the image noise was measured at the center of the phantom, and the points of 12, 3, 6 and 9 o’clock direction respectively. Some points were placed beyond the scan field of view (SFOV), so that measurement was not possible at that points. The results are as follows: The CTDIw showed a larger decrease as the source goes farther from the iso-center or the BC became wider. The CTDIw depends on the BC width more than the number of the channel of a detector array. The value of CTDIW decreased with increasing BC, but the value decreased 16.6~31.9% in the head phantom scan in air scan and 51.0~64.5% in the body phantom scan. The value of the noise was 3.9~5.9 in the head and 5.3~7.4 in the body except for BC of 2×0.5mm, regardless of the degree of deviation from the iso-center. When a subject was located within the SFOV, the position did not significantly affect image quality even if the subject was out of the center.

Abstract

The purpose of this study was to determine the dose distribution and image quality according to slice thickness and BC(beam collimation) in the gantry aperture. CT scans were performed with a 64-slice MDCT(Brilliance 64, Philips, Cleveland, USA) scanner. To determine the dose distribution according to BC, a ionization chamber was placed at isocenter and 5, 10, 15, 20, 25 and 30cm positions from the isocenter in the 12, 3, 6 and 9 o’clock directions. The dose distribution for phantom scan was also measured using CT head and body dose phantom with five holes at the center of the phantom and the positions of the 12, 3, 6 and 9 o’clock directions. The image noise measurement for different BCs was performed using an AAPM CT phantom. Water-filled block of the phantom was moved by 5cm or 10cm to the 12 o’clock direction, and the image noise was measured at the center of the phantom, and the points of 12, 3, 6 and 9 o’clock direction respectively. Some points were placed beyond the scan field of view (SFOV), so that measurement was not possible at that points. The results are as follows: The CTDIw showed a larger decrease as the source goes farther from the iso-center or the BC became wider. The CTDIw depends on the BC width more than the number of the channel of a detector array. The value of CTDIW decreased with increasing BC, but the value decreased 16.6~31.9% in the head phantom scan in air scan and 51.0~64.5% in the body phantom scan. The value of the noise was 3.9~5.9 in the head and 5.3~7.4 in the body except for BC of 2×0.5mm, regardless of the degree of deviation from the iso-center. When a subject was located within the SFOV, the position did not significantly affect image quality even if the subject was out of the center.

참고문헌 (21)

  1. A. Kaul, "Effective doses to members of the public from the diagnostic application of ionizing radiation in Germany", Eur Radiol, 7, pp.1127~1132 (1997)
  2. PC. Shrimpton, "CT scanner dosimetry", Br J Radiol, 71, pp.1~3 (1998)
  3. International Commission on Radiological Protection, "Recommendations of the International Commission on Radiological Protection. Oxford, United Kingdom", pp.60~ (1991), Pergamon Press, ICRP Publication
  4. JR. Mayo, "CT of the chest : minimal tube current required for good image quality with the least radiation dose", AJR, Am. J. Roentgenol, 164, pp.603~607 (1995)
  5. SE. Kearney, "CT scanning of the paranasal sinuses—the effect of reducing mAs", Br. J. Radiol, 70, pp.1071~1074 (1997)
  6. CH. McCollough, "Optimization of multidetector array CT acquisition parameters for CT colonography", Abdom. Imaging, 27, pp.253~259 (2002)
  7. OW. Linton, "National conference on dose reduction in CT, with an emphasis on pediatric patients", AJR Am J Roentgenol, 181, pp.321~329 (2003)
  8. SJ. Yates, "Effect of multislice scanners on patient dose from routine CT examinations in East Anglia", Br J Radiol, 77, pp.472~478 (2004)
  9. G. Brix, "Radiation exposure in multi-slice versus single-slice spiral CT : results of a nationwide survey", Eur Radiol, 13, pp.1979~1991 (2003)
  10. AN. Primak, "Relationship between Noise, Dose, and Pitch in Cardiac Multi–Detector Row CT", Radigraphics, 26(6), pp.1785~1794 (2006)
  11. SJ. Anthony, "Specification, Acceptance testing and quality control of diagnostic X-ray imaging equipment", Medical physics monograph No., 20, pp.899~936 (1991)
  12. JE. Gray, , Radiological protection issue in mammography and computed tomography proc. conf. (Vienna : IAEA), pp.183~200 (2001)
  13. PK Cho, "The development of a diagnostic reference level on patient dose for CT examination in Korea", Radiation Protection Dosimetry, 129(4), pp.463~468 (2008)
  14. LM. Roberto, "Radiation exposure of patients who undergo CT of the trunk", Radiology, 195(2), pp.557~562 (1995)
  15. LN. Rothenberg, "CT dosimetry and radiation safety. in: Syllubus, a categorical course in diagnostic radiology physics-CT and US cross-sectional imaging. Oak Brook, Ill", pp.171~188 (2000), Radiological Society of North America
  16. CM. McCollough, "Performance evaluation of CT systems. in: Syllubus : a categorical course in diagnostic radiology physics-CT and US cross-sectional imaging. Oak Brook, Ill", pp.189~207 (2000), Radiological Society of North America
  17. HD. Nagel, "Radiation exposure in computed tomography. 2nd ed" (2000), COCIR
  18. F. Michale, "AAPM", RSNA Physics Tutorial for Residents, 2002, pp.22, 1541~1553

관련 논문AI추천

이 간행물의 다른 논문 (11건)