본문 바로가기
KERD
논문KCI 등재

적외선 기반의 혈관외유출 검출시스템을 이용한 조영제의 혈관외유출 검출

Detection of Extravasated Contrast Media Using an Infrared Ray Based Extravasation Detection Accessory System

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

he purpose of this study was to assess the ability of this device during clinically important episodes of extravasation. The extravasation detection accessory (EDA) system was based of infrared ray with detection sensor, an amplifier, alarm device, receiver, cable and a computer based system. This study was a prospective, observational study in which the EDA system was used to monitor the automated mechanical injection of contrast media. Three hundred patients referred for contrast media enhanced body computed tomography studied in a prospective, observation study in which the EDA system was used to identify and interrupt any injection associated with clinically important extravasation. There were 8 true-positive cases, 276 true-negative cases, 15 false-positive cases and 1 false-negative cases. The EDA system had a sensitivity of 88.8% and a specificity of 94.8% for the detection of clinically important extravasation. The EDA system had good sensitivity for the detection of clinically important extravasation and the EDA system has the clinical potential for the early detection of extravasation of the contrast medium that is administered with power injectors.

Abstract

he purpose of this study was to assess the ability of this device during clinically important episodes of extravasation. The extravasation detection accessory (EDA) system was based of infrared ray with detection sensor, an amplifier, alarm device, receiver, cable and a computer based system. This study was a prospective, observational study in which the EDA system was used to monitor the automated mechanical injection of contrast media. Three hundred patients referred for contrast media enhanced body computed tomography studied in a prospective, observation study in which the EDA system was used to identify and interrupt any injection associated with clinically important extravasation. There were 8 true-positive cases, 276 true-negative cases, 15 false-positive cases and 1 false-negative cases. The EDA system had a sensitivity of 88.8% and a specificity of 94.8% for the detection of clinically important extravasation. The EDA system had good sensitivity for the detection of clinically important extravasation and the EDA system has the clinical potential for the early detection of extravasation of the contrast medium that is administered with power injectors.

참고문헌 (15)

  1. S. T. Cochran, "Trends in adverse events after IV administration of contrast media", Am. J. Roentgenol, 176, pp.1385~1388 (2001)
  2. T. Shimizu, "Helical CT of the liver with computed-assisted bolus tracking technology: scan delay of arterial phase scanning and effect of flow rate", J. Comput. Assist. Tomogr, 24(2), pp.219~223 (2000)
  3. B. A. Birnbaum, "Extravasation detection accessory: clinical evaluation in 500 patients", Radiology, 212, pp.431~438 (1999)
  4. S. L. Sistrom, "Extravsastion of iopamidol and iohexhol during contrast-enhancement CT: report of 28 cases", Radiology, 180, pp.707~710 (1991)
  5. S. G. Miles, "Safe use of an intraveous power injector for CT: experience and protocol", Radiology, 190, pp.69~70 (1990)
  6. R. C. Nelson, "Contrast media extravasation during dynamic CT: detection with an extravasation detection accessory", Radiology, 209, pp.837~843 (1998)
  7. C. L. Wang, "Frequency, management, and outcome of extravasation of nonionic iodinated contrast medium in 69657 intravenous injections", Radiology, 243, pp.80~87 (2007)
  8. 권대철, "전산화단층검사에서 조영제의 피하 정맥 혈관외유출 환자의 3D영상", 의학물리, 16(1), pp.47~51 (2005), 한국의학물리학회
  9. D. C. Kweon, "3D MDCT reformation findings of the radiographic contrast medium extravasation", J. Contents Assoc, 6(5), pp.145~152 (2006)
  10. J. Shaeffer, "Early detection of extravasation of radiographic contrast medium. Work in progress", Radiology, 184, pp.141~144 (1992)
  11. 권대철, "CT 검사에서 조영제의 혈관외유출 예방을 위한 EDA 시스템 개발의 예비 보고", 의학물리, 17(1), pp.32~39 (2006), 한국의학물리학회
  12. 권대철, "잡견에서 조영제 혈관외유출 예방을 위한 스트레인 게이지기반의 EDA 시스템 성능 평가를 위한 실험적 연구", 의공학회지, 29(1), pp.66~72 (2008), 대한의용생체공학회
  13. M. P. Federle, "Frequency and effects of extravasation of ionic and nonionic CT contrast media during rapid bolus injection", Radiology, 206, pp.637~640 (1998)
  14. J. E. Jacobs, "Contrast media reactions and extravasation: relationship to intravenous injection rates", Radiology, 209, pp.411~416 (1998)
  15. D. A. Mercer, "A 14-b 2.5 MSPS pipelined ADC with on-chip EPROM", IEEE J. Solid State Circuits, 31(1), pp.70~76 (1996)

관련 논문AI추천

이 간행물의 다른 논문 (10건)