본문 바로가기
KERD
논문KCI 등재

Beam Spoiler-dependent Total Body Irradiation Dose Assessment

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류방사선과학

초록

This study examined the properties of photons and the dose distribution in a human body via a simulation where the total body irradiation(TBI) is performed on a pediatric anthropomorphic phantom and a child size water phantom. Based on this, we tried to find the optimal photon beam energy and material for beam spoiler. In this study, MCNPX (Ver. 2.5.0), a simulation program based on the Monte Carlo method, was used for the photon beam analysis and TBI simulation. Several different beam spoiler materials (plexiglass, copper, lead, aluminium) were used, and three different electron beam energies were used in the simulated accelerator to produce photon beams (6, 10, and 15 MeV). Moreover, both a water phantom for calculating the depth-dependent dosage and a pediatric anthropomorphic phantom for calculating the organ dosage were used. The homogeneity of photon beam was examined in different depths for the water phantom, which shows the 20%–40% difference f or e ach m aterial. N ext, t he o rg an d oses o n pediatric anthropomorphic phantom were examined, and the results showed that the average dose for each part of the body was skin 17.7 Gy, sexual gland 15.2 Gy, digestion 13.8 Gy, liver 11.8 Gy, kidney 9.2 Gy, lungs 6.2 Gy, and brain 4.6 Gy. Moreover, as for the organ doses according to materials, the highest dose was observed in lead while the lowest was observed i n plexig lass. P lexiglass i n current use is c onsidered t he most suitable material, a nd a 6 o r 10 MV p hoton energ y plan tailored to the patient condition is considered more suitable than a higher energy plan.

Abstract

This study examined the properties of photons and the dose distribution in a human body via a simulation where the total body irradiation(TBI) is performed on a pediatric anthropomorphic phantom and a child size water phantom. Based on this, we tried to find the optimal photon beam energy and material for beam spoiler. In this study, MCNPX (Ver. 2.5.0), a simulation program based on the Monte Carlo method, was used for the photon beam analysis and TBI simulation. Several different beam spoiler materials (plexiglass, copper, lead, aluminium) were used, and three different electron beam energies were used in the simulated accelerator to produce photon beams (6, 10, and 15 MeV). Moreover, both a water phantom for calculating the depth-dependent dosage and a pediatric anthropomorphic phantom for calculating the organ dosage were used. The homogeneity of photon beam was examined in different depths for the water phantom, which shows the 20%–40% difference f or e ach m aterial. N ext, t he o rg an d oses o n pediatric anthropomorphic phantom were examined, and the results showed that the average dose for each part of the body was skin 17.7 Gy, sexual gland 15.2 Gy, digestion 13.8 Gy, liver 11.8 Gy, kidney 9.2 Gy, lungs 6.2 Gy, and brain 4.6 Gy. Moreover, as for the organ doses according to materials, the highest dose was observed in lead while the lowest was observed i n plexig lass. P lexiglass i n current use is c onsidered t he most suitable material, a nd a 6 o r 10 MV p hoton energ y plan tailored to the patient condition is considered more suitable than a higher energy plan.

참고문헌 (21)

  1. Kim SH, "Identification of symptoms by treatment phases in children with leukemia", pp.2009
  2. Park YK, "The impacts of the in-patient' copayment waiver policy on medical services and outcomes for leukemia children", pp.2008
  3. 김석란, "급성백혈병의 유전적 이상 검출을 위한 형광제자리부합 프로필 검사의 임상적 유용성", Annals of Laboratory Medicine, 29(5), pp.371~378 (2009), 대한진단검사의학회
  4. Beaumais TA, "Determinants of mercaptopurine toxicity in paediatric acute lymphoblastic leukemia maintenance therapy", British Journal of clinical Pharmacology, 71(4), pp.575~584 (2010)
  5. The Physical Aspects of Total and Half Body Photon Irradiation, "Van Dyk J", Radiation Therapy Committee American Association of Physics in Medicine, ~, pp.AAPM REPORT NO. 17 (1986)
  6. Thomas ED, "One hundred patients with acute leukemia treated by chemotherapy, total body irradiation, and allogeneic marrow transplantation", Blood J, 49(4), pp.511~533 (1977)
  7. 김상정, "소아 백혈병 환자의 동종 조혈모세포이식 전처치로서 전신방사선 조사 포함군과 비포함군의 비교", Clinical and Experimental Pediatrics, 53(4), pp.538~547 (2010), 대한소아청소년과학회
  8. Perez CA, "Principles and Practice of Radiation Oncology" (2004), Lippincott Williams & Wilkins
  9. Aristei C, "Total-body irradiation in the conditioning regimens for autologous stem cell transplantation in lymphoproliferative diseases", The oncologist, 4, pp.386~397 (1999)
  10. Denis B, "Pelowits. MCNPXTM User's manual version2.5.0" (2005)
  11. Lin JP, "Investigation of photoneutron dose equivalent from high-energy photons in radiotherapy", Applied Radiation and Isotopes, 65, pp.599~604 (2007)[DOI]
  12. Huang WL, "Calculation of photoneutrons produced in the targets of electron linear accelerators for radiography and radiotherapy applications", Nucl Instr and Meth in Phy Res, B229, pp.339~347 (2005)
  13. Han EY, "Revision to the ORNL series of adult and pediatric computational phantoms for use with the MIRD schema", Health Phys, 90, pp.337~356 (2006)[DOI]
  14. Valentin J, "ICRP 89: Basic Anatomical and Physiological Data for Use in Radiological Protection Reference Values", Internatioal Commission on Radiological Protection, ~ (2002)
  15. ICRU Report 46:Photon, electron, proton and neutron interaction data for body tissues, "White DR", Internatioal Commission on Radiation Units and Measurements, ~ (1992)
  16. Choi JH, "Analysis of surface dose refer to distance between beam spoiler and patient in total body irradiation", J Korea Soc Ther Radiol, 19(1), pp.51~54 (2007)
  17. Lee MY, "The effect of x-ray filter materials in the skin dose & tube loading at x-ray examinations", pp.2005
  18. Ravichandran R, "Beam configuration and physical parameters of clinical high energy photon beam for total body irradiation (TBI)", Phys Med, 27, pp.163~168 (2011)[DOI]
  19. Mesbahi A, "Monte Carlo calculation of Varian 2300C", D Linac photon beam characteristics: a comparison between MCNP4C, GEANT3 and measurements, 2005, pp.62(3), 469~477
  20. Baumgartner A, "Simulation of photon energy spectra from Varian 2100C and 2300C", D Linacs: Simplified estimates with PENELOPE Monte Carlo models, 2009, pp.67(11), 2007~2012
  21. Clare Mckay, "Beyond cancer treatment - a review of total lymphoid irradiation for heart and lung transplant recipients", Journal of medical radiation science, 61, pp.202~209 (2014)[DOI]

관련 논문AI추천

소아백혈병 환자의 전신방사선조사 시 조직보상체의 재질변화에 따른 선량평가김정훈, 김창수, 이동연대한방사선과학회 · Journal of Radiological Science and Technology2015 · 제38권 제1호Dose coefficients for ICRP pediatric mesh-type reference computational phantoms under idealized external electron exposures김찬형, 문성호, 신방호, 염연수, 최찬수, Bolch Wesley E.한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제12호Implication of ICRP pediatric reference voxel phantoms on dose assessment of patients in radioiodine therapy고슬기, 김찬형, 민철희, 신방호, 염연수, 이수민, 최지원, 최찬수한국원자력학회 · Nuclear Engineering and Technology2024 · 제56권 제6호몬테칼로 기법을 이용한 CBCT의 인체 내 장기의 흡수선량 평가김종보, 박은태, 임인철대한방사선과학회 · Journal of Radiological Science and Technology2018 · 제41권 제3호Dose coefficients for the ICRP pediatric mesh-type reference computational phantoms under idealized external photon exposure geometries김찬형, 신방호, 염연수, 최찬수, Bolch Wesley E.한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제9호Pediatric phantom library constructed from ICRP mesh-type reference computational phantoms (MRCPs)김수현, 김재효, 김찬형, 김현일, 문성호, 손가희, 신방호, 염연수, 정범선, 최지원, 최찬수, 하상석, 한혜진한국원자력학회 · Nuclear Engineering and Technology2024 · 제56권 제8호

이 간행물의 다른 논문 (10건)