Implication of ICRP pediatric reference voxel phantoms on dose assessment of patients in radioiodine therapy
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
To investigate the impact of the recently released pediatric reference voxel phantoms (0-, 1-, 5-, 10-, 15-year-old males and females) of the International Commission on Radiological Protection (ICRP) on organ dose estimates for radioactive iodine (RAI) treatment in pediatric patients, we calculated and analyzed pediatric-specific iodine- 131 S values (rT ← thyroid) for the 30 radiosensitive organs by conducting Monte Carlo simulations using the Geant4. The gender dependency in the S values was frequently seen for the 15-year-old phantoms with higher S values of female than male. In addition, the age dependency in the S values was observed for most target organs; that is, the S values tend to decrease for older ages (e.g., ~120 times for the gonads between the adult and newborn) due mainly to the inter-organ distances generally longer for older ages. Moreover, we observed that the iodine-131 S values tend to be significantly greater by up to ~145.5 times than those of the stylized phantoms that have been widely used for organ dose estimates of pediatric RAI patients. We believe that the pediatricspecific iodine-131 S values (rT ← thyroid) of the ICRP pediatric reference voxel phantoms should be beneficial to improve the dosimetry of pediatric RAI patients.
Abstract
To investigate the impact of the recently released pediatric reference voxel phantoms (0-, 1-, 5-, 10-, 15-year-old males and females) of the International Commission on Radiological Protection (ICRP) on organ dose estimates for radioactive iodine (RAI) treatment in pediatric patients, we calculated and analyzed pediatric-specific iodine- 131 S values (rT ← thyroid) for the 30 radiosensitive organs by conducting Monte Carlo simulations using the Geant4. The gender dependency in the S values was frequently seen for the 15-year-old phantoms with higher S values of female than male. In addition, the age dependency in the S values was observed for most target organs; that is, the S values tend to decrease for older ages (e.g., ~120 times for the gonads between the adult and newborn) due mainly to the inter-organ distances generally longer for older ages. Moreover, we observed that the iodine-131 S values tend to be significantly greater by up to ~145.5 times than those of the stylized phantoms that have been widely used for organ dose estimates of pediatric RAI patients. We believe that the pediatricspecific iodine-131 S values (rT ← thyroid) of the ICRP pediatric reference voxel phantoms should be beneficial to improve the dosimetry of pediatric RAI patients.
참고문헌 (30)
- E. Ron, "For the cooperative thyrotoxicosis therapy follow-up study group, cancer mortality following treatment for adult hyperthyroidism", JAMA, 280, pp.347~355 (1998)[DOI]
- E. Pasqual, "Association between Radioactive Iodine Treatment for Pediatric and Young Adulthood Differentiated Thyroid Cancer and Risk of Second Primary Malignancies", JCO (2022)[DOI]
- S. L. Lutterman, "The efficacy and short-and long-term side effects of radioactive iodine treatment in pediatric Graves’ disease : a systematic review", Eur. Thyroid J, 10, pp.353~363 (2021)
- G. H. Seo, "Radioactive iodine treatment for children and young adults with thyroid cancer in South Korea: a population-based study", J. Clin. Endocrinol. Metabol, 106, pp.e2580~e2588 (2021)
- C. M. Kitahara, "Association of radioactive iodine treatment with cancer mortality in patients with hyperthyroidism", JAMA Intern. Med, 179, pp.1034~1042 (2019)[DOI]
- D. R. Melo, "Organ dose estimates for hyperthyroid patients treated with 131I : an update of the thyrotoxicosis follow-up study", Radiat. Res, 184, pp.595~610 (2015)[DOI]
- Y. S. Yeom, "Iodine-131 S values for use in organ dose estimation of Korean patients in radioiodine therapy", Nucl. Eng. Technol (2021)[DOI]
- ICRP, "Radiation dose to patients from radiopharmaceuticals: a compendium of current information related to frequently used substances. ICRP publication 128", Ann, ICRP, 44(2S) (2015)
- "MIRD Pamphlet No. 11(Revised): “S” Absorbed Dose Per Unit Cumulated Activity for Selected Radionuclides and Organs" (1975)[URL]
- ICRP, "Adult reference computational phantoms. ICRP publication 110", Ann. ICRP, 39(2) (2009)
- S. Lamart, "S values for 131 I based on the ICRP adult voxel phantoms", Radiat. Protect. Dosim, 168, pp.92~110 (2016)[DOI]
- ICRP, "Paediatric computational reference phantoms. ICRP publication 143", Ann. ICRP, 49(1) (2020)
- D. Villoing, "Organ dose calculator for diagnostic nuclear medicine patients based on the ICRP reference voxel phantoms and biokinetic models", Biomed. Phys. Eng. Express, 9, pp.015004~ (2022)[DOI]
- C. Lee, "The UF family of reference hybrid phantoms for computational radiation dosimetry", Phys. Med. Biol, 55, pp.339~ (2009)[DOI]
- ICRP, "Basic anatomical and physiological data for use in radiological protection reference values, ICRP Publication 89", Ann. ICRP, 32(3–4) (2002)
- ICRP, "Dose coefficients for external exposures to environmental sources. ICRP Publication 144", Ann. ICRP, 49(2) (2020)
- ICRP, "Specific Absorbed Fractions for Reference Paediatric Individuals, 155, ICRP Publication", Ann ICRP (2024)
- ICRP, "The 2007 recommendations of the international commission on radiological protection. ICRP publication 103", Ann. ICRP, 37(2–4) (2007)
- J. Allison, "Recent developments in Geant4", Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip, 835, pp.186~225 (2016)[DOI]
- ICRP, "Nuclear decay data for dosimetric calculations. ICRP publication 107", Ann. ICRP, 38(3) (2008)
- ICRP, "Conversion coefficients for radiological protection quantities for external radiation exposures. ICRP publication 116", ann, ICRP, 40(2–5) (2010)
- "Specific Absorbed Fractions of Energy at Various Ages from Internal Photon Sources: 6, Newborn" (1987)[URL]
- "Specific Absorbed Fractions of Energy at Various Ages from Internal Photon Sources: 2, One-Year-Old" (1987)[URL]
- "Specific Absorbed Fractions of Energy at Various Ages from Internal Photon Sources: 3, Five-Year-Old" (1987)[URL]
- "Specific Absorbed Fractions of Energy at Various Ages from Internal Photon Sources: 4, Ten-Year-Old" (1987)[URL]
- "Specific Absorbed Fractions of Energy at Various Ages from Internal Photon Sources: 5, Fifteen-Year-Old Male and Adult Female" (1987)[URL]
- "Specific Absorbed Fractions of Energy at Various Ages from Internal Photon Sources: 7, Adult Male" (1987)[URL]
- Y. S. Yeom, "Body-size-dependent iodine-131 S values", J. Radiol. Prot, 40, pp.1311~1320 (2020)[DOI]
- G. Jarry, "A Monte Carlobased method to estimate radiation dose from spiral CT : from phantom testing to patient-specific models", Phys. Med. Biol, 48, pp.2645~ (2003)[DOI]