As the number of Coronavirus Disease-19 (COVID-19) patients increases in a global pandemic situation, the usefulness of mobile computed tomography (CT) is gaining attention. Currently, mobile CT follows the basic safety and essential performance evaluation criteria of whole-body or limited-view X-ray CT in order to obtain device approval and evaluation in the Republic of Korea. Unlike stationary CT, mobile CT is not operated in shielded areas but rather areas such as intensive care units, operating rooms, or isolation rooms. Therefore, it requires a different basic safety and essential performance evaluation standard than stationary CT. In this study, four derived basic safety evaluation criteria related to electrical, mechanical, and radiation safety were included (dose indication test, protection against stray radiation, safety measures against excessive X-rays, half-value layer measurement); and seven essential performance evaluation criteria were included (tube voltage accuracy, mAs accuracy, radiation dose reproducibility, CT number of water, noise, uniformity, and spatial resolution); total eleven basic safety and essential performance evaluation criteria were selected. This study aims to establish appropriate basic safety and essential performance evaluation criteria for simultaneously obtaining images with diagnostic value and reducing the exposure of nearby patients, medical staff, and radiologic technologists during the use of mobile CT.
Abstract
As the number of Coronavirus Disease-19 (COVID-19) patients increases in a global pandemic situation, the usefulness of mobile computed tomography (CT) is gaining attention. Currently, mobile CT follows the basic safety and essential performance evaluation criteria of whole-body or limited-view X-ray CT in order to obtain device approval and evaluation in the Republic of Korea. Unlike stationary CT, mobile CT is not operated in shielded areas but rather areas such as intensive care units, operating rooms, or isolation rooms. Therefore, it requires a different basic safety and essential performance evaluation standard than stationary CT. In this study, four derived basic safety evaluation criteria related to electrical, mechanical, and radiation safety were included (dose indication test, protection against stray radiation, safety measures against excessive X-rays, half-value layer measurement); and seven essential performance evaluation criteria were included (tube voltage accuracy, mAs accuracy, radiation dose reproducibility, CT number of water, noise, uniformity, and spatial resolution); total eleven basic safety and essential performance evaluation criteria were selected. This study aims to establish appropriate basic safety and essential performance evaluation criteria for simultaneously obtaining images with diagnostic value and reducing the exposure of nearby patients, medical staff, and radiologic technologists during the use of mobile CT.
참고문헌 (22)
- Rubin DG, "Computed tomography: Revolutionizing the practice of medicine for 40 years", Radiology, 273(25), pp.S45~S74 (2014)
- Waydhas C, "Equipment review: Intrahospital transport of critically ill patients", Crit Care, 3, pp.R83~ (1999)
- Temsah MH, "Adverse events experienced with intrahospital transfer of critically ill patients", Medicine, 100(18), pp.e25810~ (2021)
- "Coronavirus Disease (COVID-19) Pandemic"[URL]
- Rubin DG, "Radiology department preparedness for COVID-19: Radiology scientific expert review panel", Radiology, 296(2), pp.E106~E112 (2020)
- 신형호, "코로나바이러스감염증-19 상황에서 일개 국가지정 의료기관의 이동형 병원 CT 활용 사례", 방사선기술과학, 43(2), pp.71~77 (2020), 대한방사선과학회
- Ministry of Health and Welfare, "Guidance for temporary use of mobile CT in isolation wards for COVID-19 response", ~ (2020)
- Ministry of Health and Welfare, "Rules on the safety management of diagnostic radiation generating devices. No. 777", ~ (2021)
- Enforcement policy for imaging systems during the coronavirus disease 2019 (COVID-19) public health emergency, "Food and Drug Administration", ~, pp.FDA-2020-D-1138 (2020)
- Ministry of Food and Drug Safety, "Regulations on medical device item and classification", Ministry of Food and Drug Safety Notice No. 2021-24, ~ (2021)
- Food and Drug Administration, "Computed tomography x-ray system. FDA-892.1750", ~
- Basic requiremetns conformity checklist: standard for whole-body X-ray CT diagnostic equipment, "Ministry of Health, Labor and Welfare", ~, pp.MHLWNo. 112
- "International Electrotechnical Commission IEC 60601-2-44:2009 Medical electrical equipment-Part 2-44: Particular requirements for the basic safety and essential performance of X-ray equipment for computed tomography", ~ (2009)
- "International Electrotechnical Commission IEC 61223-3-5:2019 Evaluation and routine testing in medical imaging departments- Part 3-5: Acceptance and constancy tests - Imaging performance of computed tomography X-ray equipment", ~ (2019)
- "International Electrotechnical Commission IEC 60601-1-3:2021 Medical electrical equipment-Part 1-3: General requirements for basic safety and essential performance- Collateral Standard:Radiation protection in diagnostic X-ray equipment", ~ (2021)
- "International Electrotechnical Commission IEC 60601-2-54:2009 Medical electrical equipment-Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy", ~ (2009)
- Ministry of Health and Welfare, "Rules on the installation and operation of special medical equipment. No. 672, Article 5(2)", ~ (2019)
- Ministry of Food and Drug Safety, "Medical device standard: attached table 2, appliance equipment 49 whole body X-ray computed tomography system", ~ (2001)
- 최민혁, "전산화단층촬영검사 시 검사실 내에 위치할 수 있는 의료인의 간접 피폭선량에 대한 연구", 방사선기술과학, 42(2), pp.105~111 (2019), 대한방사선과학회
- Radiation protection guidance diagnostic and interventional X-ray procedures, "Intergency Working Group on Medicla Radiation U.S. Environmental Protection Agency", ~, pp.Federal guidance report No. 14
- Radiation protection and safety in medical uses of ionizing radiation: IAEA safety standards for protection people and the environment, "International Atomic Energy Agency", ~, pp.IAEA- DS399
- Mollura JD, "Radiology in global health: strategies, implementation, and applications" (2019), Springer