이동형 방사선 차폐장치의 성능평가에 관한 연구

A Study on the Performance Evaluation of Portable Radiation Shielding Apparatus

2

조회

0

다운로드

3

인용

0

참고문헌

키워드

주제분류방사선과학

초록

When using a mobile X-ray unit, primary radiation creates medical images and secondary radiation scatters in many directions, which reduces image quality and causes exposure to patients, care givers and medical personnel. The purpose of this study was to develop a radiation shielding system for effectively shielding secondary radiation and evaluate its effectiveness. Using a mobile X-ray unit, spatial dose according to presence of human equivalent phantom and spatial dose using the developed shielding device were measured, and the phantom at 80 cm equidistance from center of X-ray was compared with spatial dose according to use of a shield. Measurements were taken at intervals of 10 cm every 30° from the head direction(-90°) to the body direction(+90°). In the spatial dose measurement with and without the phantom, when the human equivalent Phantom was used, the spatial dose was increased by 40% in all directions from 40 cm to 100 cm from the central X-ray, and about 88% of the space dose was reduced when using the developed shields with the phantom. The equidistance dose at 80 cm from the central X-ray was increased by 39% from 5.1±0.26 μ Gy to 7.1±0.15 μGy when the human equivalent phantom was used, and when phantom was used and shielding was used, the spatial dose was reduced by about 90% from 7.1±0.15 μGy to 0.7±0.07 μGy. The spatial dose of natural radiation was measured to be about 0.2±0.04 μGy when using the developed shielding with Phantom at a distance of 1 m or more. It is expected that by using the developed shielding system, it will be possible to effectively reduce secondary radiation dose received in all directions and to ensure safe imaging.

Abstract

When using a mobile X-ray unit, primary radiation creates medical images and secondary radiation scatters in many directions, which reduces image quality and causes exposure to patients, care givers and medical personnel. The purpose of this study was to develop a radiation shielding system for effectively shielding secondary radiation and evaluate its effectiveness. Using a mobile X-ray unit, spatial dose according to presence of human equivalent phantom and spatial dose using the developed shielding device were measured, and the phantom at 80 cm equidistance from center of X-ray was compared with spatial dose according to use of a shield. Measurements were taken at intervals of 10 cm every 30° from the head direction(-90°) to the body direction(+90°). In the spatial dose measurement with and without the phantom, when the human equivalent Phantom was used, the spatial dose was increased by 40% in all directions from 40 cm to 100 cm from the central X-ray, and about 88% of the space dose was reduced when using the developed shields with the phantom. The equidistance dose at 80 cm from the central X-ray was increased by 39% from 5.1±0.26 μ Gy to 7.1±0.15 μGy when the human equivalent phantom was used, and when phantom was used and shielding was used, the spatial dose was reduced by about 90% from 7.1±0.15 μGy to 0.7±0.07 μGy. The spatial dose of natural radiation was measured to be about 0.2±0.04 μGy when using the developed shielding with Phantom at a distance of 1 m or more. It is expected that by using the developed shielding system, it will be possible to effectively reduce secondary radiation dose received in all directions and to ensure safe imaging.

참고문헌 (21)

  1. Ionizing radiation exposure of the population of United States, "NCRP", NCRP, 160~ (2009)
  2. Gil JW, "Estimated effective dose from diagnostic medical radiation in korean and factors that affect the high-level dose", pp.2015
  3. "A study on investigation and analysis of medical radiation usage" (2010)[URL]
  4. ICRP, "Avoidance of radiation injuries from medical interventional procedures. ICRP publication 85", Ann ICRP, 30(2) (2000)
  5. ICRP, "The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103", Ann ICRP, 37(2-4) (2007)
  6. Grazer RE, "Exposure to ionizing radiation in the emergency department from commonly performed portable radiographs", Ann Emerg Med, 16(4), pp.17~20 (1987)
  7. Ciraulo DL, "Do surgical residents, emergency medicine physicians, and nurses experience significant radiation exposure during the resuscitation of trauma patients?", Journal of Trauma and Acute Care Surgery, 36(5), pp.703~705 (1994)[DOI]
  8. 정주환, "응급센터에 근무하는 의사의 방사선 피폭에 관한 연구", 대한응급의학회지, 19(1), pp.125~130 (2008), 대한응급의학회
  9. Rules for safety management of diagnostic radiation generators, "Ministry of Health and Welfare", Ministry of Health and Welfare, ~, pp.No.528 (2010)
  10. Calton RR, "Principles of radiographic image: An Art and a science", pp.267~270 (2001), Delmar Thomson Learning
  11. 나수경, "엑스선 촬영실의 공간산란선 발생 인자에 관한 연구", 방사선기술과학, 32(4), pp.393~399 (2009), 대한방사선과학회
  12. 백철하, "디지털 방사선영상 시스템에서 산란선이 영상 품질에 미치는 영향", 방사선기술과학, 40(1), pp.71~77 (2017), 대한방사선과학회[DOI]
  13. Korea Food & Drug Administration, "Electronic medical device specification", Korea Food & Drug Administration Notice 2007-83, ~ (2007)
  14. McCaffrey JP, "Radiation attenuation by lead and nonlead materials used in radiation shielding garments", Medical Physics, 34(2), pp.530~743 (2007)[DOI]
  15. "Korea Intellectual Property Office", 2018
  16. Hong SS, "Measurement of Skin Dose Distribution for the Mobile X-ray Unit Collimator Shielding Device", Journal of the Korean Society for Digital Imaging in Medicine, 12(1), pp.5~8 (2010)
  17. 최대연, "Portable X-ray 검사 시 주변 환자 피폭선량 감소 방안 연구", 한국방사선학회논문지, 7(2), pp.113~120 (2013), 한국방사선학회[DOI]
  18. Ministry of Health and Welfare, "Medical law enforcement regulations. Ministry of Health and Welfare No 511", ~ (2017)
  19. Park CH, "Analysis of Space Radiation Dose Rate using Portable X-ray Generating Device for Abdomen", Journal of the Korean Society for Digital Imaging in Medicine, 12(2), pp.97~101 (2010)
  20. U.S. Department of Health and Human services, "Guidelines for protecting the safety and health care workers", U.S. government printing office, ~ (1998)
  21. ", KAERI"[URL]

관련 논문AI추천

이 간행물의 다른 논문 (9건)