이동형 방사선검사에서 영상의 왜곡과 선량에 관한 연구
A Study on Distortion and Dose of Images in Mobile Radiography
0
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
The proportion and testing of portable radiation tests, which are limited at the request of the doctor, are gradually increasing only for patients in emergency situations and difficulties in moving. However, as there are many limiting factors compared to fixed devices, this study intends to measure and analyze the distortion of images according to the angle of the detector and the change in dose according to the position of the subject. For distortion experiments using a mobile radiation generator used in Hospital A, the SID was tilted by 110 cm, 14"×17" wireless FPD detector to 0°, -5°, -10°, -15°, -20°, and -35° to measure the change in area. The dose according to the location of the detector was analyzed on average by measuring the central dose at 110 cm of the SID and measuring the dose of 9 locations three times each. The analysis result of distortion by location according to the angle of the detector showed a statistically significant difference (f=58.74, p<0.000). Therefore, it can be seen that the angle of the detector and the tube is closely related to the distortion of the image. The difference in dose by location of the detector increased with respect to the center - pole, and decreased with the + pole. Tests using mobile radiation generators will require careful efforts by clinicians to position patients in the center of the detector for accurate diagnosis, and efforts will be made to level the angle between the mobile radiation generators and the detector.
Abstract
The proportion and testing of portable radiation tests, which are limited at the request of the doctor, are gradually increasing only for patients in emergency situations and difficulties in moving. However, as there are many limiting factors compared to fixed devices, this study intends to measure and analyze the distortion of images according to the angle of the detector and the change in dose according to the position of the subject. For distortion experiments using a mobile radiation generator used in Hospital A, the SID was tilted by 110 cm, 14"×17" wireless FPD detector to 0°, -5°, -10°, -15°, -20°, and -35° to measure the change in area. The dose according to the location of the detector was analyzed on average by measuring the central dose at 110 cm of the SID and measuring the dose of 9 locations three times each. The analysis result of distortion by location according to the angle of the detector showed a statistically significant difference (f=58.74, p<0.000). Therefore, it can be seen that the angle of the detector and the tube is closely related to the distortion of the image. The difference in dose by location of the detector increased with respect to the center - pole, and decreased with the + pole. Tests using mobile radiation generators will require careful efforts by clinicians to position patients in the center of the detector for accurate diagnosis, and efforts will be made to level the angle between the mobile radiation generators and the detector.
참고문헌 (16)
- Kim BG, "Assessment of Exposure Index based on Changes of Tube Angle in Portable X-ray Examination using Digital Wireless Detector", Journal of the Korean Society of Radiology, 1, pp.39~47 (2016)
- "Radiographic simple image(HIRA)"[URL]
- "1 image (HIRA)"[URL]
- Im JK, "Thoracic Radiology Science", pp.29~34 (2000), Ilchokak Publishing
- Kang SS, "Textbook of Radiographic Positioning and Clinical Diagnosis", pp.670~726 (2019), Chung-Ku Publisher
- 주영철, "디지털방사선 환경에서 흉부 후 - 전 방향 검사 시 초점과 영상수용체간 거리의 적절성", 방사선기술과학, 39(2), pp.135~142 (2016), 대한방사선과학회[DOI]
- 최대연, "Portable X-ray 검사 시 주변 환자 피폭선량 감소 방안 연구", 한국방사선학회논문지, 7(2), pp.113~120 (2013), 한국방사선학회[DOI]
- "Coronavirus Infectious Disease-19 outbreak status in Korea" (2022)[URL]
- Jin Yong Kim, "The First Case of 2019 Novel Coronavirus Pneumonia Imported into Korea from Wuhan, China: Implication for Infection Prevention and Control Measures", Journal of Korean Medical Science, 35(5), pp.1~4 (2020), 대한의학회[DOI]
- Adam Jacobi, "Portable chest X-ray in coronavirus disease-19 (COVID-19): A pictorial review", Clinical Imaging, 64, pp.35~42 (2020), Elsevier BV[DOI]
- De Moura J, "Deep Convolutional Approaches for the Analysis of COVID-19 Using Chest X-Ray Images From Portable Devices", IEEE Access, 8, pp.195594~195607 (2020)
- 이진수, "Mobile Chest AP 검사 시 환자자세와 입사각도에 따른 Levin-tube tip의 영상왜곡 분석", 한국방사선학회논문지, 9(7), pp.467~471 (2015), 한국방사선학회[DOI]
- 유영은, "디지털 무선 검출기를 이용한 이동형 X선검사에서 영상품질 저하의 요인분석", 방사선기술과학, 37(2), pp.93~100 (2014), 대한방사선과학회
- 조평곤, "흉, 복부 단순 X-ray 검사 시 영상의 질 향상 방법", 한국방사선학회논문지, 7(3), pp.165~173 (2013), 한국방사선학회[DOI]
- Shin JB, "Study on the Distortion Factor of the Images of the Stitching Method Depending on the Angle of X-Ray Tube Using Phantom", Journal of Korean Society of Radiological Imaging Technology, 14(1), pp.35~45 (2017)
- 최준구, "디지털 방사선검사에서 선량증가와 영상품질저하의 요인 분석", 박사, 생물과학(방사선), pp.2008