Facial Exposure Dose Assessment During Intraoral Radiography by Radiological Technologists
1
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
The study examined the changes in the decreased facial exposure dose for radiological technologists depending on increased distance between the workers and the X-ray tube head during intraoral radiography. First, the facial phantom similar to the human tissues was manufactured. The shooting examination was configured to the maxillary molars for adults (60kVp, 10mA, 50msec) and for children (60kVp, 10mA, 20msec), and the chamber was fixed where the facial part of the radiation worker would be placed using the intraoral radiography equipment. The distances between the X-ray tube head and the phantom were set to 10cm, 15cm, 20cm, 25cm, 30cm, 35cm, and 40cm. The phantom was radiated 20 times with each examination condition and the average scattered doses were examined. The rate at the distance of 40cm decreased by about 92.6% to 7.43% based on the scattered rays radiated at the distance of 10cm under the adult conditions. The rate at the distance of 40cm decreased by about 97.6% to 2.58% based on the scattered rays radiated at the distance of 10cm under the children conditions. Protection from the radiation exposure was required during the dental radiographic examination.
Abstract
The study examined the changes in the decreased facial exposure dose for radiological technologists depending on increased distance between the workers and the X-ray tube head during intraoral radiography. First, the facial phantom similar to the human tissues was manufactured. The shooting examination was configured to the maxillary molars for adults (60kVp, 10mA, 50msec) and for children (60kVp, 10mA, 20msec), and the chamber was fixed where the facial part of the radiation worker would be placed using the intraoral radiography equipment. The distances between the X-ray tube head and the phantom were set to 10cm, 15cm, 20cm, 25cm, 30cm, 35cm, and 40cm. The phantom was radiated 20 times with each examination condition and the average scattered doses were examined. The rate at the distance of 40cm decreased by about 92.6% to 7.43% based on the scattered rays radiated at the distance of 10cm under the adult conditions. The rate at the distance of 40cm decreased by about 97.6% to 2.58% based on the scattered rays radiated at the distance of 10cm under the children conditions. Protection from the radiation exposure was required during the dental radiographic examination.
참고문헌 (18)
- 임현술, "특집", 보건의료인의 물리적 인자에 의한 건강장애 - 전리방사선을 중심으로 -, 2010, pp.53(6), 483~491[DOI]
- 정규환, "고용량 131I 투여환자 퇴원이후 환자 간병인과 환자 가옥의 피폭선량 측정", 방사선기술과학, 33(2), pp.149~154 (2010), 대한방사선과학회
- Jeong TS, "The Analysis of radiation exposure of hospital radiologic technologists", Korean Soc Ther Radiol Oncol, 18, pp.157~166 (2000)
- 이병도, "방사선사진 검사 선택기준에 대한 고찰", 대한치과의사협회지, 51(1), pp.39~45 (2013), 대한치과의사협회
- "ncidental findings from cone beam computed tomography of the maxillofacial region: a descriptive retrospective study", Clin Oral Implants Res, 23, pp.1261~1268 (2012)
- Fryback DG, "The efficacy of diagnostic imaging", Med Decis Making, 11, pp.88~94 (1991)
- 안서영, "구강검진에서 임상검사와 비교한 파노라마방사선사진의 유용성", Imaging Science in Dentistry, 37(2), pp.83~86 (2007), 대한구강악안면방사선학회
- Memon A, "Dental x-rays and the risk of thyroid cancer: a case-control study", Acta Oncol, 49, pp.447~453 (2010)
- Claus EB, "Dental x-rays and risk of meningioma", Cancer, 118, pp.4530~4537 (2012)
- Ludlow JB, "The Risks of Radiographic imaging", Dimensions of Dental Hygiene, 10, pp.59~61 (2012)
- "ICRP 60: 1990 Recommendations of the International Commission on Radiological Protection", Ann ICRP 60, ~ (1991)
- "ICRP 20: Alkaline Earth Metabolism in Adult Man", Ann ICRP 20, ~ (1973)
- 조정연, "이동형 구내 방사선촬영기로 촬영한 치근단 방사선사진의흡수선량 및 유효선량 평가", Imaging Science in Dentistry, 37(3), pp.149~156 (2007), 대한구강악안면방사선학회
- Hatziioannou K, "Quality control and diagnostic reference levels in intraoral dental radiographic facilities", Dentomaxillofac Radiol, 34, pp.304~307 (2005)
- Underhill TE, "Radiobiologic risk estimation from dental radiology. Part I. absorbed doses to critical organs", Oral Surg Oral Med Oral Pathol, 66, pp.111~120 (1988)
- Avendanio B, "Effective dose and risk assessment from detailed narrow beam radiography", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 82, pp.713~719 (1996)
- 임청환, "치과 방사선 검사 시 노출 위험성에 따른 피폭선량 방어연구", 한국방사선학회논문지, 5(5), pp.237~244 (2011), 한국방사선학회
- Park EC, "A Study on the Scatter Radiation Affecting the Dental X-ray Film", Korean J Oral Maxillofac Radiol, 22, pp.41~55 (1992)