The use of dental radiographic examinations is common although radiation dose resulting from the dental radiography is relatively small. Therefore, it is required to evaluate radiation dose from the dental radiography for radiation safety purpose. The objectives of the present study were to develop dosimetry method for intraoral dental radiography using a Monte Carlo method based radiation transport code and to calculate organ doses and effective doses of patients from different types of intraoral radiographies. Radiological properties of dental radiography equipment were characterized for the evaluation of patient radiation dose. The properties including x-ray energy spectrum were simulated using MCNP code. Organ doses and effective doses to patients were calculated by MCNP simulation with computational adult phantoms. At the typical equipment settings (60 kVp, 7 mA, and 0.12 sec), the entrance air kerma was 1.79 mGy and the measured half value layer was 1.82 mm. The half value layer calculated by MCNP simulation was well agreed with the measurement values. Effective doses from intraoral radiographies ranged from 1 μSv for maxilla premolar to 3 μSv for maxilla incisor. Oral cavity layer (23~82 μSv) and salivary glands (10~68 μSv) received relatively high radiation dose. Thyroid also received high radiation dose (3~47 μSv) for examinations. The developed dosimetry method and evaluated radiation doses in this study can be utilized for policy making, patient dose management, and development of low-dose equipment. In addition, this study can ultimately contribute to decrease radiation dose to patients for radiation safety.

Abstract

The use of dental radiographic examinations is common although radiation dose resulting from the dental radiography is relatively small. Therefore, it is required to evaluate radiation dose from the dental radiography for radiation safety purpose. The objectives of the present study were to develop dosimetry method for intraoral dental radiography using a Monte Carlo method based radiation transport code and to calculate organ doses and effective doses of patients from different types of intraoral radiographies. Radiological properties of dental radiography equipment were characterized for the evaluation of patient radiation dose. The properties including x-ray energy spectrum were simulated using MCNP code. Organ doses and effective doses to patients were calculated by MCNP simulation with computational adult phantoms. At the typical equipment settings (60 kVp, 7 mA, and 0.12 sec), the entrance air kerma was 1.79 mGy and the measured half value layer was 1.82 mm. The half value layer calculated by MCNP simulation was well agreed with the measurement values. Effective doses from intraoral radiographies ranged from 1 μSv for maxilla premolar to 3 μSv for maxilla incisor. Oral cavity layer (23~82 μSv) and salivary glands (10~68 μSv) received relatively high radiation dose. Thyroid also received high radiation dose (3~47 μSv) for examinations. The developed dosimetry method and evaluated radiation doses in this study can be utilized for policy making, patient dose management, and development of low-dose equipment. In addition, this study can ultimately contribute to decrease radiation dose to patients for radiation safety.

참고문헌 (17)

  1. 진단용방사선발생장치의 검사기준 및 검사방법 가이드라인, "식품의약품안전처", ~, pp.방사선안전관리 시리즈 No.29 (2012)
  2. 진단용 방사선 사용에 따른 국민 방사선량 평가 연구, "식품의약품안전처", ~, pp.연구결과보고서 13172방사선579 (2013)
  3. ADA, "Intraoral radiography positioning and radiation protection" (2009), American Dental Association
  4. Gonzalez L, "Reference doses in dental radiodiagnostic facilities", Brit. J. Radiol, 74, pp.153~156 (2001)
  5. Dosimetry in Diagnostic Radiology; An International Code of Practice, "IAEA.", International Atomic Energy Agency, ~, pp.Technical Report series No.457 (2007)
  6. ICRP., "Conversion Coefficients for Use in Radiological Protection against External Radiation. ICRP Publication 74", International Commission on Radiological Protection, ~ (1997)
  7. ICRP., "Managing Patient Dose in Multi-Detector Computed Tomography. ICRP Publication 102", International Commission on Radiological Protection, ~ (2007)
  8. ICRP., "The 2007 recommendations of the International Commission on Radiological Protection. ICRP Publication 103", International Commission on Radiological Protection, ~ (2007)
  9. Catalogue of diagnostic x-ray spectra and other data, "IPEM.", Institute of Physics and Engineering in Medicine, ~, pp.IPEM Report 78 (1997)
  10. How to assess the dose to the patient in diagnostic radiology, "IRPA", International Radiation Protection Association, ~, pp.IRPA 9 (1996)
  11. Johnson PB, "Response functions for computing absorbed dose to skeletal tissues from photon irradiation-an update", Med. Phys. Biol, 56, pp.2347~2365 (2011)
  12. Lee C, "Organ and effective doses in pediatric patients undergoing helical multislice computed tomography examination", Med. Phys, 34(5), pp.1858~1873 (2007)
  13. Looe HK, "Radiation Exposure to Children in Intraoal Dental Radiology", Radiat. Prot. Dosim, 121(4), pp.461~465 (2006)
  14. Ludlow JB, "Patient Risk Related to Common Dental Radiographic Examinations: The Impact of 2007 International Commission on Radiological Protection Recommendations Regarding Dose Calculation", J. Am. Dent. Assoc, 138, pp.1237~1243 (2008)
  15. Makarevich KO, "Modelling Dental X-ray Examinations for Assessment of Radiation Doses to Patients", Central European Researchers Journal, 2(1), pp.1~8 (2016)
  16. Sirona Dental Systems Gmbh, "Heliodent Plus DHHSStatements", ~ (2009)
  17. UNSCEAR, "Sources and effects of ionizing radiation Vol. I Source" (2010), United Nations Scientific Committee on the Effects of Atomic Radiation

관련 논문AI추천