초록
Objectives: This study was aimed to investigate the methods to reduce operator’s radiation dose when taking intraoral radiographs with portable dental X-ray machines. Materials and Methods: Two kinds of portable dental X-ray machines (DX3000, Dexcowin and Rextar, Posdion) were used. Operator’s radiation dose was measured with an 1,800 cc ionization chamber (RadCal Corp.) at the hand level of X-ray tubehead and at the operator’s chest and waist levels with and without the backscatter shield. The operator’s radiation dose at the hand level was measured with and without lead gloves and with long and short cones. Results: The backscatter shield reduced operator’s radiation dose at the hand level of X-ray tubehead to 23 - 32%, the lead gloves to 26 - 31%, and long cone to 48 - 52%. And the backscatter shield reduced operator’s radiation dose at the operator’s chest and waist levels to 0.1 - 37%. Conclusions:When portable dental X-ray systems are used, it is recommended to select X-ray machine attached with a backscatter shield and a long cone and to wear the lead gloves.
Abstract
Objectives: This study was aimed to investigate the methods to reduce operator’s radiation dose when taking intraoral radiographs with portable dental X-ray machines. Materials and Methods: Two kinds of portable dental X-ray machines (DX3000, Dexcowin and Rextar, Posdion) were used. Operator’s radiation dose was measured with an 1,800 cc ionization chamber (RadCal Corp.) at the hand level of X-ray tubehead and at the operator’s chest and waist levels with and without the backscatter shield. The operator’s radiation dose at the hand level was measured with and without lead gloves and with long and short cones. Results: The backscatter shield reduced operator’s radiation dose at the hand level of X-ray tubehead to 23 - 32%, the lead gloves to 26 - 31%, and long cone to 48 - 52%. And the backscatter shield reduced operator’s radiation dose at the operator’s chest and waist levels to 0.1 - 37%. Conclusions:When portable dental X-ray systems are used, it is recommended to select X-ray machine attached with a backscatter shield and a long cone and to wear the lead gloves.
참고문헌 (18)
- Coy JD, "Use of lightweight X-ray machine and processor during Riverine medical readiness training exercise on the Amazon River", Mil Med, 156, pp.623~628 (1991)
- Van Dis ML, "Information yield from a hand-held dental x-ray unit", Oral Surg Oral Med Oral Pathol, 76, pp.381~385 (1993)
- Coy J, "Hand-held dental X-ray (HDX) with medical collimator: use in casualty radiology", Mil Med, 161, pp.428~431 (1996)
- Coy J, "Use of the handheld dental X-ray machine during joint operation, NATO exercise Display Determination-92", Mil Med, 162, pp.575~577 (1997)
- Varghese S, "In vitro evaluation of the XR-15 portable x-ray unit for forensic odontology", J Forensic Odontostomatol, 22, pp.5~8 (2004)
- Charlton DG, "Portable dental equipment: dental units and x-ray equipment", Gen Dent, 57, pp.336~341 (2009)
- Hermsen KP, "Radiation safety for the NOMAD™ portable X-ray system in a temporary morgue setting", J Forensic Sci, 53, pp.917~921 (2008)
- "Dental X-ray installations, R325.5396. Hand-held portable dental x-ray systems" (2012)[URL]
- "Washington state legislature: Radiation safety and diagnostic image quality standards for dental facilities, chapter 246-225A-085 Hand-held X-ray system" (2012)[URL]
- 김은경, "이동용 치과 X선 발생장치의 누설 및 산란 선량에 관한 연구", Imaging Science in Dentistry, 37(2), pp.65~68 (2007), 대한구강악안면방사선학회
- "Regulation for the safety management of diagnostic x-ray equipments" (2012)[URL]
- Danforth RA, "Operator exposure to scatter radiation from a portable hand-held dental radiation emitting device (Aribex™ NOMAD™) while making 915 intraoral dental radiographs", J Forensic Sci, 54, pp.415~421 (2009)
- Goren AD, "Radiation exposure with the NOMAD™ portable X-ray system", Dentomaxillofac Radiol, 37, pp.109~112 (2008)
- Gray JE, "Dental staff doses with handheld dental intraoral x-ray units", Health Phys, 102, pp.137~142 (2012)
- White SC, "Oral radiology; principles and interpretation 6th ed", pp.148~149 (2009), Mosby-Year Book Inc
- "Aribex NOMAD™ dental portable x-ray system for intraoral radiographic imaging. User manual" (2006)[URL]
- Pittayapat P, "Image quality assessment and medical physics evaluation of different portable dental X-ray units", Forensic Sci Int, 201, pp.112~117 (2010)