초록

Panoramagraphy was the second most used intraoral radiography utilized in Korea, resulting in 17.8% in university dental hospitals, 24.8% in dental hospitals, and 31.4% in dental clinics. Depending on increased demand like orthodontics and implant, panoromagraphy tends to consistently increase.This study were used lead glasses and lead shielding to reduce unnecessary radiation to the eyeballs and thyroid. ESD was 41.4% when radiation was shielded with the lead glasses while reducing 47.3% of ESD by shielding the X-ray tube area with shielding lead. There was no statistically significant difference. The lead glasses is appropriated to reduce unnecessary radiation exposure to the eyeballs.

Abstract

Panoramagraphy was the second most used intraoral radiography utilized in Korea, resulting in 17.8% in university dental hospitals, 24.8% in dental hospitals, and 31.4% in dental clinics. Depending on increased demand like orthodontics and implant, panoromagraphy tends to consistently increase.This study were used lead glasses and lead shielding to reduce unnecessary radiation to the eyeballs and thyroid. ESD was 41.4% when radiation was shielded with the lead glasses while reducing 47.3% of ESD by shielding the X-ray tube area with shielding lead. There was no statistically significant difference. The lead glasses is appropriated to reduce unnecessary radiation exposure to the eyeballs.

참고문헌 (10)

  1. EK. Kim, "Use of radiation in the field of dental history and facts", Radiation health Newsletter, 18(4), pp.1~4 (2011), Korea National Institute of Food and Drug Safety Evaluation
  2. 신귀순, "국내 치과방사선의 현황 및 이용 실태", 방사선기술과학, 33(2), pp.109~120 (2010), 대한방사선과학회
  3. Korea Ministry of Food and Drug Safety, "Radiation safety management series No.34, Pediatric Patient dose in General Imaging inspection recommended guidelines", ~ (2013)
  4. 최정현, "STUDY ON ENTRANCE SKIN DOSE AT PANORAMIC RADIOGRAPHY IN INCHEON, KOREA", 방사선방어학회지, 39(4), pp.182~186 (2014), 대한방사선방어학회
  5. HI. Kang, "Radiation for dental Imaging", pp.195~196 (2013), Daihak Pub
  6. Diagnostic x-ray equipment regulation on safety management, , ~, pp.The Ministry of Health decree No.291 (2015)
  7. M.S. Akselroda, "Optically stimulated luminescence and its use in medical dosimetry", Radiation Measurements, 41(1), pp.78~99 (2007)
  8. Von H. Whitley, "Photoionization of deep centers in Al2O3", Journal of applied physics, 87, pp.249~ (2000)
  9. A.J.J. Bos, "High sensitivity thermoluminescence dosimetry", Nuclear Instruments and methods in physics reach B, 184, pp.3~28 (2001)
  10. 김창규, "자체제작 Pb 밴딩을 이용한 피폭선량 감소", 디지털융복합연구, 11(6), pp.269~273 (2013), 한국디지털정책학회

관련 논문AI추천

이 간행물의 다른 논문 (14건)